Olympus FV300の取扱説明書

16ページ 2.28 mb
ダウンロード

ページに移動 of 16

Summary
  • Olympus FV300 - page 1

    CONFOCAL LASER SCANNING BIOLOGICAL MICROSCOPES FV300 FLUOVIEW ...

  • Olympus FV300 - page 2

    1 FV300 CONFOCAL LASER SCANNING MICROSCO PERFORMANCE FOR THE PERSONAL USER The FV300 is the ideal choice of laser scanning microscopes for personal users. Its optical system is fully integrated, from scanner to microscope, and not only delivers outstanding optical sectioning, but also ensures the easy, flexible expandability required for any future ...

  • Olympus FV300 - page 3

    2 OPE q e r t y u i o !0 !1 !2 w q Optical fiber for laser introduction w Beam collimator e Polarizer r Dichromatic mirror t Excitation dichromatic mirror y XY galvanometer mirror scanners u Pupil lens i Collector Lens o Pinhole turret !0 Emission beam splitter slider !1 Barrier filter slider !2 Photo multiplier ...

  • Olympus FV300 - page 4

    Preset the conditions for image acquisition and loading Storage of Acquisition Settings enables immediate, one-touch recall of all the relevant experimental settings and conditions. Adding new conditions or altering existing ones is quick and easy. AOTF: flexible control of the laser intensity to meet the specific demands (optional) The laser expos ...

  • Olympus FV300 - page 5

    Image tool bar X-Y-Z scanning operations and time- lapse observations both produce multiple images, which can be displayed in sequence simply by clicking the sequential mode button. Channel selection and image zooming are also available on the same menu. 4 Thumbnail display Data stored in the gallery window are displayed as thumbnails for easy view ...

  • Olympus FV300 - page 6

    5 X -t Slant Line-t FreeLine-t Y -t Y-Z-t X-Y-t ZoomIn-t X-Z-t X-Y-t X-Y-Z-t ZoomIn-Z-t Patch clamp BX61WI fixed stage upright microscope+translation stage Image acquisition ROI designation Intensity versus time measurement Calcium sparks in isolated cardiac myocyte Dr. Sandor Gyorke Texas Technical University X -t X -t Time Course Using different ...

  • Olympus FV300 - page 7

    6 The 440nm diode laser can be added for CFP/YFP FRET imaging. A 440nm diode laser is optionally available for CFP/YFP imaging. The 440nm laser line ideally excites CFP, with minimal disturbance to YFP, and is therefore suitable for CFP/YFP FRET experiments. The high performance LSM objectives, PLAPO40XWLSM and PLAPO60XWLSM, are precisely corrected ...

  • Olympus FV300 - page 8

    7 PAPP for FRAP Application PAPP: Programmable Acquisition Protocol Processor Easy, reliable flow of experiments for fluorescence recovery after photobleaching. AOTF and PAPP function for effective FRAP (Fluorescence Recovery After Photobleaching) Fluorescence recovery after photobleaching can be analyzed on any designated area by means of the AOTF ...

  • Olympus FV300 - page 9

    8 Multi-point time lapse system High-magnification multi-point time lapse observation of living cells. Wide-ranging specimen observations for improved experiment throughput Use of a motorized XY stage allows the analysis of time lapse changes in many points scattered over a wide area. The system is therefore effective for work with thick specimens, ...

  • Olympus FV300 - page 10

    9 Tile display Topographic projection Height of 3D structure indicated by color. X-Z Y-Z X-Y-Z X -Z Y -Z Using multiple 3D images to obtain accurate 3D structure analysis. 3D Imaging Easy Z axis operation and setting The upper and lower limit of Z scanning can be specified interactively by actually scanning the sample or by direct input of the nume ...

  • Olympus FV300 - page 11

    10 Link with patch clamping data • With PCs linked through a LAN, Physiolink can synchronize electrophysiological and confocal image data simultaneously. • With the same time stamp recorded in the two PCs, it is possible to access and analyze an image and its patch clamping data corresponding to the Physiolink software time scale. • The patch ...

  • Olympus FV300 - page 12

    11 Lucifer Yellow: retina ganglion cell TexasRed: dopamine-operated amacrine cell Prof. Shigetada Nakanishi Dept. of Biological Sciences, Kyoto Univ. Faculty of Medicine Applications Gallery Morphology Structure of PtK2 cell Nucleus: DAPI (Blue) Actin: FITC (Green) Mitochondria: Mito Tracker (Red) Microtubules: Cy5 (White) Neuron Rat tongue taste b ...

  • Olympus FV300 - page 13

    12 Fluorescent Proteins C elegans expressing beta-integrin fused to GFP Dr. Xioping Xhu and Dr. John Plenefisch University of Toledo, Dept. of Biology GFP-labeling of Drosophila adults Expression of DsRed in a zebrafish embryo Extended focus image of 5µmx30 slice Pr. Yasuhiro Kamei, Pr. Shunsuke Yuba Institute for Molecular and Cellular Biology Os ...

  • Olympus FV300 - page 14

    Fluorescence Dyes and Filters 300 400 500 600 700 BA530RIF BA550RIF BA650RIF BA430-460 BA465-495 BA480-495 BA470-520 BA510-540 BA520-550 BA505-550 BA505-525 BA480-510 BA535-565 BA540-590 BA560-600 BA585-615 BA510IF BA560IF BA565IF BA585IF BA590 BA610IF BA625IF BA660IF BA585-640 440 LD 405 LD 458 Multi Argon 488 Multi Argon 515 Multi Argon 543 Green ...

  • Olympus FV300 - page 15

    Objectives for fixed stage upright microscopes (using WI-UCD, WI-DICTHRA) 14 Item Specifications Laser light Visible light laser source Select from the following laser, to mounted on laser combiner source Multi-line Ar laser (458nm, 488nm, 515nm, Total 40mW), Ar laser (488nm,10mW), Kr laser (568nm, 10mW), HeNe (G) laser (543nm,1mW), HeNe (R) laser ...

  • Olympus FV300 - page 16

    ● All brands are trademarks or registered trademarks of their respective owners. ● Monitor images are simulated. Specifications are subject to change without any obligation on the part of the manufacturer. This catalog is printed by enviromentally-friendly waterless printing system with soy ink. ISO 900 1 Certification Design and production adh ...

メーカー Olympus カテゴリー Microscope & Magnifier

Olympus FV300のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FV300の取扱説明書
- Olympusの製品カード
- パンフレット
- またはOlympus FV300の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Olympus FV300の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Olympus FV300の取り付け説明書、サービスマニュアル、簡易説明書、またはOlympus FV300のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Olympus FV300の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Olympus FV300デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOlympus FV300を使用するのを助ける技術的文書のことです。説明書は通常、全てのOlympus FV300ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Olympusの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Olympus FV300の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOlympus FV300の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Olympus FV300に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Olympus FV300デバイスの基本機能を使うにあたってのヒント。 Olympus FV300のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Olympus FV300に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOlympus FV300のメーカー/サービスへの連絡先に関する情報。

Olympus FV300についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOlympus FV300の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOlympus FV300で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)