Epson 250Dの取扱説明書

12ページ 0.31 mb
ダウンロード

ページに移動 of 12

Summary
  • Epson 250D - page 1

    V ideo Analyser -2000 The most advanced computerised high definition system for the microscopic analysis of fibers, yarns and fabrics. The system is composed by: - Leica Biological Microscope. - Leica S tereo-Microscope. - Professional colour Video camera with 1/2’’ CCD. - Optical fibre illumination device (150W) with two 50 cm arms . - « Mesd ...

  • Epson 250D - page 2

    EQUIPMENT SUIT ABLE TO : - Check the purchased material (searching for possible foreign fibres) and identify the type of fibre, comparing it with the fibre pictures stored in the DataBank, with both the longitudinal and the sectional views. Viscose fibre in longitudinal and sectional view . Longitudinal image of a cotton and a wool fibre, to highli ...

  • Epson 250D - page 3

    - Analyse the yarn structure and detect possible defect s . Check the single threads of a twisted yarn; check the single yarn fibres. - Measure the count of circular section yarns and filament s in Dtex or den . - Detect, identify and measure possible impurities contained in textile materials (neps, pollution due to foreign fibre content in a fabri ...

  • Epson 250D - page 4

    - Analyse mechanical p arts (i.e. needle point s, spinneret s, etc). - Perform a micro analysis of yarns and fibre sections . - Measure section surfaces and perimeters. Example of a nozzle of a splicer mingling chamber . Example of spinning rings Example of spinnerets ...

  • Epson 250D - page 5

    - Reduce the fabric warp and wef t density to a cm or a inch. The operator simply traces a reference line of desired length on the warp and weft and identifies the number of threads. The «Mesdan Video Analyser» software automatically determines the number of threads per cm (and inch). The collected data are automatically exported onto an excel sh ...

  • Epson 250D - page 6

    DATA: Material Materiale POLIESTER Nylon 0 0 0 Measure number Numero di misure 10 10 0 0 0 11 Mean/ Media 20,380 25,080 Max 22,200 25,900 Min 19,700 24,000 CV[%] 3,604 2,074 3,604 2,074 #VALORE! Dev. St 0,735 0,520 Range [%] 12,267 7,576 Specific weight Peso specifico (g/cm³) 1,38 1,14 1,0 1,0 Count (Dtex) 2,210 2,000 Count (Denari) 1,989 1,800 N? ...

  • Epson 250D - page 7

    LEICA biological Microscope with professional lenses, recommended for the longitudinal and sectional analysis of fibres and yarns. - High quality and accuracy Microscope - Phototube trinocular viewing body with Siedentopf design, to adjust the interpupillary distance without changing the focussing. - Koehler illumination device for the phase contra ...

  • Epson 250D - page 8

    SYSTEM COMPOSITION LENS IN USE ON SCREEN MAGNIFICATION ON SCREEN FIELD OF VISION (mm) 0.63X 20X 11.6 1X 32X 6.8 1.6X 51X 4.1 2.5X 80X 1.9 4X 128X 1.6 Note: by using the 0.50X additional lens between the microscope and the video-camera (available as optional) the on screen magnification rate decreases by 50% and the field of vision increases by 50%. ...

  • Epson 250D - page 9

    High flexibility to perform measurements on stored images as well as on live images (in accordance with International S tandards). Measurements of lengths, surfaces, perimeters, angles, dist ances between two point s or lines or object s. The software allows to save a picture (complete with measurements and comments) into the Data Bank and to compa ...

  • Epson 250D - page 10

    1) Window to display the live picture: it is possible to store and/or print a picture complete with comments and measurements. It is then possible to perform measurements and send them to an Excel template in order to obtain statistics. 2) View finder window on the area where measurements are being taken, in order to guarantee the maximum measure a ...

  • Epson 250D - page 11

    Personal Computer IBM PC complete with «Mesdan Video Analyser» acquisition card, Philips LCD 17’’ monitor and photographic quality Epson printer . A set of ink cartridges and high definition photographic paper is supplied as spare. Sample preparation and analysis kit Calibration slide Necessary for the system routines calibration. 1) Complete ...

  • Epson 250D - page 12

    Optional accessories (to be ordered separately) 63X LENS (for the Biological Microscope) as replacement of one of the 4 lenses supplied as standard with the microscope, it enables a 2000X on screen magnification. Code 250 336 C-STEP CONNECTOR WITH 0.5X LENS (for the Biological Microscope) The installation of this connector allows to halve the magni ...

メーカー Epson カテゴリー Stereo Receiver

Epson 250Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 250Dの取扱説明書
- Epsonの製品カード
- パンフレット
- またはEpson 250Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Epson 250Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Epson 250Dの取り付け説明書、サービスマニュアル、簡易説明書、またはEpson 250Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Epson 250Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Epson 250Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEpson 250Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのEpson 250Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Epsonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Epson 250Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEpson 250Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Epson 250Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Epson 250Dデバイスの基本機能を使うにあたってのヒント。 Epson 250Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Epson 250Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEpson 250Dのメーカー/サービスへの連絡先に関する情報。

Epson 250Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEpson 250Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEpson 250Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)