  • Lincoln Electric V155-S - page 1

    INVER TEC ® V155-S SVM183-A July , 2008 For use with machines having Code Numbers: 1 1326; 1 1327 SER VICE MANUAL Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC View Safety Info View Safety Info View Safety Info View Safety Info • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland ...

  • Lincoln Electric V155-S - page 2

    SAFETY i i Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b.Operate engines in open, well-ventilated ar ...

  • Lincoln Electric V155-S - page 3

    SAFETY ii ii Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FUMES AND GASES can be dangerous. 5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes and gases ...

  • Lincoln Electric V155-S - page 4

    S S A A F F E E T T Y Y i i i i i i i i i i i i Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Jan ʻ07 FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrica ...

  • Lincoln Electric V155-S - page 5

    SAFETY iv iv Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Mar ʻ93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûre ...

  • Lincoln Electric V155-S - page 6

    SAFETY v v Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Electromagnetic Compatibility (EMC) Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (89/3 ...

  • Lincoln Electric V155-S - page 7

    SAFETY vi vi Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Electromagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises. Methods ...

  • Lincoln Electric V155-S - page 8

    I I - MASTER T ABLE OF CONTENTS FOR ALL SECTIONS - INVERTEC® V155-S RETURN TO MAIN INDEX Page Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i-iv Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lincoln Electric V155-S - page 9

    T ABLE OF CONTENTS - INST ALLA TION SECTION A-1 A-1 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC® V155-S Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1 T echnical Specifications ...

  • Lincoln Electric V155-S - page 10

    INST ALLA TION A-2 A-2 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Input Circuit 120 V ac 230 V ac 120 V ac 230 V ac Maximum Open Circuit V oltage 75 V olts Max. Duty Cycle 100% 30% Output Current Range 5 ...

  • Lincoln Electric V155-S - page 11

    INST ALLA TION A-3 A-3 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Read entire installation section before starting installation. SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel s ...

  • Lincoln Electric V155-S - page 12

    INST ALLA TION A-4 A-4 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INPUT POWER CONNECTION Check the input voltage, phase, and frequency sup- plied to this machine before turning it on. The allowable input ...

  • Lincoln Electric V155-S - page 13

    INST ALLA TION A-5 A-5 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TIG WELDING This machine does not hav e a built in Gas Solenoid so a one piece gas valv e TIG T orch is required. A K960-2 T wist-Mate™ ...

  • Lincoln Electric V155-S - page 14

    INST ALLA TION A-6 A-6 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC REPLA CEMENT Q UICK DISCONNECT PLUG (FOR STICK ELECTR ODE CABLE) The INVER TEC® V155-S comes with a factory assem- bled stic k electrode ...

  • Lincoln Electric V155-S - page 15

    T ABLE OF CONTENTS - OPERA TION SECTION B-1 B-1 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC® V155-S Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Safety Precautions . . . . . . ...

  • Lincoln Electric V155-S - page 16

    THEOR Y OF OPERA TION B-2 B-2 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Read and understand this entire section before operating your machine. SAFETY INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not tou ...

  • Lincoln Electric V155-S - page 17

    THEOR Y OF OPERA TION B-3 B-3 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONTROLS AND OPERA TIONAL FEA TURES 1. Output Current Knob: Potentiometer used to set the output current used during welding, from ...

  • Lincoln Electric V155-S - page 18

    THEOR Y OF OPERA TION B-4 B-4 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 5. Positive Quick Disconnect: Positive output con- nector for the welding circuit. 6. Negative Quick Disconnect: Negative output c ...

  • Lincoln Electric V155-S - page 19

    T ABLE OF CONTENTS - ACCESSORIES SECTION C-1 C-1 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC® V155-S Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-1 Factory Installed Options . . . ...

  • Lincoln Electric V155-S - page 20

    ACCESSORIES C-2 C-2 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPTIONAL ACCESSORIES AND COMP A TIBLE EQUIPMENT Factory Installed Electrical Holder and Cable Assembly Work Cable and Clamp Strap Packet Ins ...

  • Lincoln Electric V155-S - page 21

    T ABLE OF CONTENTS - MAINTENANCE SECTION D-1 D-1 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC® V155-S Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1 Safety Precautions . . . . . . . ...

  • Lincoln Electric V155-S - page 22

    MAINTENANCE D-2 D-2 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY PRECA UTIONS ELECTRIC SHOCK can kill. • Hav e an electrician install and ser- vice this equipment. • T ur n the input power off a ...

  • Lincoln Electric V155-S - page 23

    MAINTENANCE D-3 D-3 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAJOR COMPONENT LOCA TIONS 1. Front Panel 2. Right Case Side 3. Left Case Side 4. Rear Panel 5. Fan 6. Cable Clamp 7. Input Cable 8. ONOFFS ...

  • Lincoln Electric V155-S - page 24

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES D-4 D-4 INVERTEC® V155-S ...

  • Lincoln Electric V155-S - page 25

    T ABLE OF CONTENTS-THEOR Y OF OPERA TION SECTION E-1 E-1 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC® V155-S Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-1 General Description . . . . . ...

  • Lincoln Electric V155-S - page 26

    THEOR Y OF OPERA TION E-2 E-2 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GENERAL DESCRIPTION The INVERTEC® V155-S is an industrial 155 amp arc welding power source which utilizes single phase input powe ...

  • Lincoln Electric V155-S - page 27

    THEOR Y OF OPERA TION E-3 E-3 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INPUT BOARD The Input Board includes the following circuits: - Automatic Reconnect Circuit : This circuit monitors the input volta ...

  • Lincoln Electric V155-S - page 28

    THEOR Y OF OPERA TION E-4 E-4 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAIN INVERTER BOARD The Inverter Board includes the following circuits: - Inverter Circuit : Through the use of Insulated Gate Bip ...

  • Lincoln Electric V155-S - page 29

    THEOR Y OF OPERA TION E-5 E-5 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONTROL BOARD The Control Board receives status and analogue sig- nals from the inverter board, input board and various sensors an ...

  • Lincoln Electric V155-S - page 30

    THEOR Y OF OPERA TION E-6 E-6 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INSULA TED GA TE BIPOLAR TRANSIST OR (IGBT) OPERA TION An IGBT is a type of transistor . IGBT s are semicon- ductors well suited f ...

  • Lincoln Electric V155-S - page 31

    THEOR Y OF OPERA TION E-7 E-7 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PULSE WIDTH MODULA TION The term PULSE WIDTH MODULA TION is used to describe how much time is devoted to conduction in the cycle. ...

  • Lincoln Electric V155-S - page 32

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES E-8 E-8 INVERTEC® V155-S ...

  • Lincoln Electric V155-S - page 33

    T ABLE OF CONTENTS - TROUBLESHOOTING & REP AIR F-1 F-1 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC® V155-S T roubleshooting and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-1 How to Use T roubleshooting Guide ...

  • Lincoln Electric V155-S - page 34

    TROUBLESHOOTING & REP AIR F-2 F-2 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the thre ...

  • Lincoln Electric V155-S - page 35

    TROUBLESHOOTING & REP AIR F-3 F-3 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrica ...

  • Lincoln Electric V155-S - page 36

    OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric V155-S - page 37

    OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric V155-S - page 38

    OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact the Lincoln Electric Service Department for technical troubles ...

  • Lincoln Electric V155-S - page 39

    CASE COVER REMOV AL PROCEDURE W ARNING Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all sa ...

  • Lincoln Electric V155-S - page 40

    I N V E R T E C V 1 5 5 Five Screws I n v e t e r B o a r d Three Screws Ground FIGURE F .1 – CASE COVER SCREW LOCA TIONS CASE COVER REMOV AL PROCEDURE (CONTINUED) PROCEDURE 1. Disconnect power to the INVER TEC® V155-S. 2. Using a phillips head screwdriver remove the five screws securing the case cover sides together . See Figure F .1. Note: The ...

  • Lincoln Electric V155-S - page 41

    INPUT FIL TER CAP ACITOR DISCHARGE PROCEDURE Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe ...

  • Lincoln Electric V155-S - page 42

    DC+ DC- I N P U T B O A R D CAP ACITOR TERMINALS (4 places) FIGURE F .2 – CAP ACITOR DISCHARGE LOCA TIONS FIGURE F .3 – GLOVE, PLIERS & REISISTOR INPUT FIL TER CAP ACITOR DISCHARGE PROCEDURE (CONTINUED) TROUBLESHOOTING & REP AIR F-10 F-10 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Secti ...

  • Lincoln Electric V155-S - page 43

    TROUBLESHOOTING & REP AIR F-11 F-11 INVERTEC® V155-S Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INPUT FIL TER CAP ACITOR DISCHARGE PROCEDURE (CONTINUED) FIGURE F .4 – CAP ACITOR DISCHARGE LOCA TIONS INVERTER BOARD ...

  • Lincoln Electric V155-S - page 44

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES F-12 F-12 INVERTEC® V155-S ...

  • Lincoln Electric V155-S - page 45

    INPUT BOARD RESIST ANCE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes ...

  • Lincoln Electric V155-S - page 46

    DC+ D C - INPUT BO ARD D 1 In p u t R e c ti fi e r R4 R2 ~ ~ + – FIGURE F .5 – INPUT BOARD TEST POINTS INPUT BOARD RESIST ANCE TEST (CONTINUED) PROCEDURE 1. Disconnect power to the INVER TEC® V155-S. 2. Perform the Case Cover Removal Procedure. 3. Perform the Input Filter Capacitor Discharge Procedure. 4. Visually check for burned areas ont T ...

  • Lincoln Electric V155-S - page 47

    INVERTER BOARD RESIST ANCE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety no ...

  • Lincoln Electric V155-S - page 48

    I NVERTER BOARD IGBT C hannel A IGBT channel B Emitter Gate C ollector Channel A Collector Channel B Emitter Gate FIGURE F .6 – INVERTER BOARD TEST POINTS INVERTER BOARD RESIST ANCE TEST (CONTINUED) PROCEDURE 1. Disconnect power to the INVER TEC® V155-S. 2. Perform the Case Cover Removal Procedure. 3. Perform the Input Filter Capacitor Discharge ...

  • Lincoln Electric V155-S - page 49

    INVERTER BOARD D9 Collector Channel B D7 D3 Output T erminals Point 2 Point 1 (center leg) R24 = PTC (solder pad) Collector Channel A Red Black FIGURE F .7 – INVERTER BOARD TEST POINTS INVERTER BOARD RESIST ANCE TEST (CONTINUED) 7. Check the diodes D3 and D9 for “shorts” or “opens”. See Figure F .7. 8. Check diode D7, but remember , some ...

  • Lincoln Electric V155-S - page 50

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES F-18 F-18 INVERTEC® V155-S ...

  • Lincoln Electric V155-S - page 51

    INPUT BOARD VOL T AGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety notes a ...

  • Lincoln Electric V155-S - page 52

    DC+ DC- I NPUT BOARD AC2 AC1 JP1 PIN 2 PIN 1 PIN 3 PIN 4 PIN 8 PIN 12 PIN 14 FIGURE F .8 – INPUT BOARD TEST POINTS INPUT BOARD VOL T AGE TEST (CONTINUED) PROCEDURE 1. Disconnect power to the INVER TEC® V155-S. 2. Perform the Case Cover Removal Procedure (left side only). 3. Connect the main 230V AC to the the machine and switch ON the input swit ...

  • Lincoln Electric V155-S - page 53

    White from PWR 2 White from PWR4 Blue from PWR 1 Blue from PWR 3 3 1 2 6 4 5 FIGURE F .9 – MAIN SWITCH PLUG LOCA TION INPUT BOARD VOL T AGE TEST (CONTINUED) 1. Put the blue wire from PWR3 in position 2 of the main switch while the white wire from PWR4 in posi- tion 5. 2. Put the blue wire from PWR1 in position 1 of the main switch while the white ...

  • Lincoln Electric V155-S - page 54

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES F-22 F-22 INVERTEC® V155-S ...

  • Lincoln Electric V155-S - page 55

    INVERTER BOARD VOL T AGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safety note ...

  • Lincoln Electric V155-S - page 56

    DC+ DC- INPUT BOARD AC2 AC1 JP1 PIN 2 PIN 1 15 1 3 1 1 9 7 5 3 16 1 4 12 10 8 6 4 FIGURE F .10 – PLUG JP1 TESTPOINTS INVERTER BOARD VOL T AGE TEST (CONTINUED) NOTE: DUE T O SAFETY REASONS AND THE PHYS- ICAL LOCA TION OF THE INVER TER, IT IS NOT EASY TO PERFORM THE VOL T AGE TEST A T THE INVER TER BOARD. CHECKS CAN BE DONE A T THE INPUT BOARD CON- ...

  • Lincoln Electric V155-S - page 57

    INPUT BOARD REMOV AL AND REPLACEMENT PROCEDURE Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observ ...

  • Lincoln Electric V155-S - page 58

    DC+ DC- INPUT BOARD AC2 AC 1 MOUNTING SCREWS FIGURE F .1 1 – SCREW AND LEAD LOCA TION INPUT BOARD REMOV AL AND REPLACEMENT PROCEDURE PROCEDURE 1. Disconnect power to the INVER TEC® V155-S. 2. Perform the Case Cover Removal Procedure (Left side only). 3. Perform the Input Filter Capacitor Discharge Procedure. 4. Label and disconnect the four lead ...

  • Lincoln Electric V155-S - page 59

    INVERTER BOARD REMOV AL AND REPLACEMENT PROCEDURE Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please obs ...

  • Lincoln Electric V155-S - page 60

    I N V E R T E C V 1 5 5 Five Screws I n v e t e r B o a r d Three Screws Ground FIGURE F .12 – DOOR REMOV AL INVERTER BOARD REMOV AL AND REPLACEMENT PROCEDURE (CONTINUED) PROCEDURE 1. Disconnect power to the INVER TEC® V155-S. 2. Perform the Case Cover Removal Procedure. 3. Perform the Input Filter Capacitor Discharge Procedure. 4. Perform the I ...

  • Lincoln Electric V155-S - page 61

    OUTPUT TERMINALS 10MM BOL TS DC- DC+ FIGURE F .13 – INVERTER BOARD REMOV AL INVERTER BOARD REMOV AL AND REPLACEMENT PROCEDURE (CONTINUED) 7. Using a 10mm nutdriver with extension, remove the two bolts mounting the inverter board to the positive (+) and negative (-) leads that connect to the output terminals on the front ot the macine. See Figure ...

  • Lincoln Electric V155-S - page 62

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES F-30 F-30 INVERTEC® V155-S ...

  • Lincoln Electric V155-S - page 63

    CONTROL BOARD REMOV AL AND REPLACEMENT PROCEDURE Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please obse ...

  • Lincoln Electric V155-S - page 64

    CONTROL BOARD MOUNTING SCREWS RED CAP KNOB W ASHER NUT FIGURE F .14 CONTROL BOARD REMOV AL CONTROL BOARD REMOV AL AND REPLACEMENT PROCEDURE (CONTINUED) PROCEDURE 1. Disconnect power to the INVER TEC® V155-S. 2. Perform the Case Cover Removal Procedure (left side only). 3. Perform the Input Filter Capacitor Discharge Procedure. 4. Perform the Input ...

  • Lincoln Electric V155-S - page 65

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-33 F-33 INVERTEC® V155-S RETEST AFTER REP AIR Should a machine under test be rejected for any reason requiring the removal of any mechanical part ...

  • Lincoln Electric V155-S - page 66

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES F-34 F-34 INVERTEC® V155-S ...

  • Lincoln Electric V155-S - page 67

    T ABLE OF CONTENTS - DIAGRAM SECTION G-1 G-1 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC® V155-S Electrical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 Wiring Diagram (W07X071) . . . . . . . . . ...

  • Lincoln Electric V155-S - page 68

    ELECTRICAL DIA GRAMS G-2 INVERTEC® V155-S WIRING DIA GRAM - CODES 11326 & 11327 G-2 NO TE: This diagram is f or reference only . It ma y not be accurate f or all machines cov ered by this man ual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of y our machine. Return to Section TOC Retur n to Section TOC ...

  • Lincoln Electric V155-S - page 69

    Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-3 INVERTEC® V155-S SCHEMA TIC - COMPLETE MA CHINE - CODES 11326 & 11327 Power Up On – – with i de-energizedfor a 230V ac windings control output ...

  • Lincoln Electric V155-S - page 70

    Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-4 INVERTEC® V155-S SCHEMA TIC - INPUT PC BO ARD RL_AUX RL_PRE RESET RL_PAR RL_AUX I RQ RL_PRE I NPUT_ERR RL_PAR RL_PAR RL_PAR R L_SER VI N2 RL_SER RL_SE ...

  • Lincoln Electric V155-S - page 71

    NO TE: Lincoln Electric assumes no responsibility for liablilities resulting from board le vel troubleshooting. PC Board repairs will inv alidate your f actor y warranty . Individual Printed Circuit Board Components are not a vailable fr om Lincoln Electric. This inf or mation is pro- vided for ref erence only . Lincoln Electric discourages board l ...

  • Lincoln Electric V155-S - page 72

    Return to Section TOC Retur n to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-6 INVERTEC® V155-S SCHEMA TIC - INVERTER PC BO ARD - SHEET #1 Gh Gh Vout Vout GND ERRORn GND DUTY V_FB M/S PRES I_FB COMP 15V T A PILOT GND 15V GND Pass ...

  • Lincoln Electric V155-S - page 73

    ELECTRICAL DIA GRAMS G-7 INVERTEC® V155-S SCHEMA TIC - INVERTER PC BO ARD - SHEET #2 A Vref Vref 15V GND Vref PRES 15V 15V 15V 15V 15V 15V T A SLA VE REC DUTY PWM MASTER P ASSIVEn COMP PTC VINint ERRORn GND 15V PRES PILO T Title Size Document Number Rev t e e h S : . v e r t s a l e t a D of Appr . Dr . This sheet contains proprietary information ...

  • Lincoln Electric V155-S - page 74

    NO TE: Lincoln Electric assumes no responsibility for liablilities resulting from board le vel troubleshooting. PC Board repairs will inv alidate your f actor y warranty . Individual Printed Circuit Board Components are not a vailable fr om Lincoln Electric. This inf or mation is pro- vided for ref erence only . Lincoln Electric discourages board l ...

  • Lincoln Electric V155-S - page 75

    NO TE: Lincoln Electric assumes no responsibility for liablilities resulting from board le vel troubleshooting. PC Board repairs will inv alidate your f actor y warranty . Individual Printed Circuit Board Components are not a vailable fr om Lincoln Electric. This inf or mation is pro- vided for ref erence only . Lincoln Electric discourages board l ...

  • Lincoln Electric V155-S - page 76

    ELECTRICAL DIA GRAMS G-10 INVERTEC® V155-S SCHEMA TIC - CONTROL PC BO ARD 1 1 A A I- Voutm OFF+ I+ AD1 RESET IRQ Voutm +15V DUTY PTCE THLED VENn Vout IMIS S/T PTCE PTCuM O SC GND GND GND ERRORn +5V IRQ AD2 ISET AD0 AD0 GND +5V DUTY ISET W ELDING Fan FAN_ONn ERRORn Arcset PTCuM OFF+ +5V RESET VRD +15V FAN_ONn AD1 AD2 Voutfi lt Voutfi lt W ELDING S/ ...

  • Lincoln Electric V155-S - page 77

    NO TE: Lincoln Electric assumes no responsibility for liablilities resulting from board le vel troubleshooting. PC Board repairs will inv alidate your f actor y warranty . Individual Printed Circuit Board Components are not a vailable fr om Lincoln Electric. This inf or mation is pro- vided for ref erence only . Lincoln Electric discourages board l ...

  • Lincoln Electric V155-S - page 78

    NO TE: Lincoln Electric assumes no responsibility for liablilities resulting from board le vel troubleshooting. PC Board repairs will inv alidate your f actor y warranty . Individual Printed Circuit Board Components are not a vailable fr om Lincoln Electric. This inf or mation is pro- vided for ref erence only . Lincoln Electric discourages board l ...

メーカー Lincoln Electric カテゴリー Portable Generator

Lincoln Electric V155-Sのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- V155-Sの取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric V155-Sの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric V155-Sの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric V155-Sの取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric V155-Sのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric V155-Sの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Lincoln Electric V155-Sデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric V155-Sを使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric V155-Sユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric V155-Sの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric V155-Sの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric V155-Sに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric V155-Sデバイスの基本機能を使うにあたってのヒント。 Lincoln Electric V155-Sのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric V155-Sに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric V155-Sのメーカー/サービスへの連絡先に関する情報。

Lincoln Electric V155-Sについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric V155-Sの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric V155-Sで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください