Bryant AIR CONDITIONER WITH PURONR 113Aの取扱説明書

22ページ 1.46 mb
ダウンロード

ページに移動 of 22

Summary
  • Bryant AIR CONDITIONER WITH PURONR 113A - page 1

    Pr oduct Dat a Model 1 13A Legacy- - RNC Series Air Condi tion er with Pu ron r A05233 the environmentally sound refrigerant Brya nt’ s Air Condit ioner s wi th Puron r r ef rige rant provi de a collectio n of features un match ed b y an y other family of equ ip m ent. Th e 113 A has been d esig n ed utilizin g B ry ant’ s Pu ro n re fri gera n ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 2

    2 MODEL NUMBER NOMENCLA TURE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 11 3 A N A 0 3 6 0 0 0 0 Prod - uct Fa m il y Tier SEER Major Series Voltag e V ar iati on s Cooling Capaci ty Open Open Open Seri es 1=AC 1= Leg acy RNC 3=13 SEER A=P uron N= 208 - - - 230 - - - 1 or 208/230 - - - 1 A=S t a n d a r d 0=Not Defi ned 0=Not D ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 3

    3 PHYS ICAL DA T A UNIT SIZE SER IES 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A Operat ing Weig ht (lb ) 125 125 134 152 189 210 236 Shippin g Weigh t (lb) 146 146 155 175 218 235 270 Compressor T ype Scroll REFRIGERAN T Puron ® (R - - - 410A) Cont rol TXV (Puron ® Hard S huto ff) Charge ( lb ) 4.25 4.35 4 ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 4

    4 ACCESSO R Y THERMOST A TS THE RMOSTAT / SUBBASE PKG. DESCR IPTION TST A TBBPRH01 - - - B Thermid istat C ontrol - - - P rog rammab le / N on - - - P rog rammab le Th ermostat with Humid ity contr ol TST A TBBP AC01 - - - B T h e r m o s t a t --- A u t o C h a n g e o v e r , 7 --- D a y P r o g r a m m a b l e , _ F/ _ C , 1 --- S t a g e H e a ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 5

    5 Accesso ry Descrip ti on an d Usa ge (Lis ted Alp h ab etica ll y) 1. Ball- -Beari ng Fan Motor A fan m o tor with b all bearin g s wh ich p erm its speed red u ctio n wh ile maintain in g b earing lu b ricatio n. Us age Gui deli ne: Req u ired o n all units wh en Mo to rMaster r — 2. C o mp ressor S ta rt Assist - - C a p acito r a n d R ela y ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 6

    6 Accesso ry Descrip tio n an d Usa ge (Lis te d Alphabet ically) ( Continue d) 14. Wi nte r Start Cont r ol This cont rol is desi gned to a lle viat e nuis anc e ope ning of the low- - pre ssur e s wit ch by bypas sing i t for the fi rs t 3 minute s of oper ati on. ELECTRICAL DA T A UNI T SIZE V/PH OPER VOL TS* COMPR FAN MCA MIN WIRE SIZE { MIN WI ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 7

    7 DIMENSIONS UNIT SERIES ELECT RI CAL CH ARACT ERIS TIC S A B C D E F G H J K L M N P 113ANA0318 A X 0 0 0 25 3/4” 25 1/8” 33 / 4 ” 5/8” 4 7/16” 21 1/4” 91 / 8 ” 5/16” 3” 2 13/16” 1/2” 12 1/2” 12 3/8” 12 3/8” 113ANA0324 A X 0 0 0 25 3/4” 25 1/8” 33 / 4 ” 5/8” 4 7/16” 21 1/4” 91 / 8 ” 5/16” 3” 2 13/16” ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 8

    8 COMBINA TION RA TINGS Unit Size - - - Vo l t a g e & Series Indoor Model To t a l C a p . BTUH Fac to ry Supplied Enhancement SEER EER Fur na ce Model Standard Rating TDR { 018 - - - A *CAP**1814A** 17,500 TXV 13.00 11.00 CAP**1814A** 17,200 TDR&TXV 14.00 11.70 315(A,J)AV036070 CAP**2414A** 17,700 TXV 13.00 11.00 CAP**2414A** 17,500 TDR&a ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 9

    9 COMBINA TION RA TINGS CONTINUED Unit Size - - - Vo l t a g e & Series Indoor Model To t a l Cap. BTUH Fac to ry Supplied Enhancement SEER EER Fur na ce Model Standard Rating TDR { 024 - - - A *CAP**2414A** 23,000 TXV 13.00 11.00 CAP**2414A** 22,600 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAP**2417A** 22,800 TXV 13.00 11.00 CAP**2417A** 22,60 ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 10

    10 COMBINA TION RA TINGS CONTINUED Unit Size - - - Vo l t a g e & Series Indoor Model To t a l C a p . BTUH Fac to ry Supplied Enhancement SEER EER Fur na ce Model Standard Rating TDR { 024 - - - A CSPH*3012A** 22,800 TDR&TXV 14.00 11.70 355AAV060080 CSPH*3012A** 22,800 TDR&TXV 14.00 11.70 355AAV060100 CSPH*3012A** 22,800 TDR&TXV 14 ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 11

    11 COMBINA TION RA TINGS CONTINUED Unit Size - - - Vo l t a g e & Series Indoor Model To t a l C a p . BTUH Fac to ry Supplied Enhancement SEER EER Fur na ce Model Standard Rating TDR { 030 - - - A CNPF*3618A** 28,000 TXV 13.00 11.00 CSPH*3012A** 28,000 TXV 13.00 11.00 CSPH*3012A** 27,600 TDR&TXV 13.50 11.20 355AAV042040 CSPH*3012A** 27,600 ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 12

    12 COMBINA TION RA TINGS CONTINUED Unit Size - - - Vo l t a g e & Series Indoor Model To t a l C a p . BTUH Fac to ry Supplied Enhancement SEER EER Fur na ce Model Standard Rating TDR { 036 - - - A CNPH*4221A** 33,800 TDR&TXV 14.00 11.50 355AAV042040 CNPH*4221A** 33,800 TDR&TXV 14.00 11.50 355AAV042060 CNPH*4221A** 33,800 TDR&TXV 14 ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 13

    13 COMBINA TION RA TINGS CONTINUED Unit Size - - - Vo l t a g e & Series Indoor Model To t a l C a p . BTUH Fac to ry Supplied Enhancement SEER EER Fur na ce Model Standard Rating TDR { 042 - - - A CNPH*4821A** 41,500 TXV 13.20 11.00 CNPH*4821A** 40,500 TDR&TXV 13.50 11.20 355AAV042040 CNPH*4821A** 41,000 TDR&TXV 13.50 11.20 315(A,J)AV0 ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 14

    14 COMBINA TION RA TINGS CONTINUED Unit Size - - - Vo l t a g e & Series Indoor Model To t a l C a p . BTUH Fac to ry Supplied Enhancement SEER EER Fur na ce Model Standard Rating TDR { 048 - - - A CNPH*4821A** 45,000 TDR&TXV 13.50 11.20 315(A,J)AV048090 CNPH*4821A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV060110 CNPH*6024A** 47,000 TXV 13 ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 15

    15 DET AILED COOLING CAP ACITIES EVAPORAT OR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 16

    16 DET AILED COOLING CAP ACITIES EVAPORAT OR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW* * Capacity MBtuh { To t a l System KW ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 17

    17 DET AILED COOLING CAP ACITIES EVAPORAT OR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 18

    18 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 19

    19 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 20

    20 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 21

    21 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l Sys- tem KW* * Capacity MBtuh { To t a l ...

  • Bryant AIR CONDITIONER WITH PURONR 113A - page 22

    22 GUIDE SPECIFICA TIONS GENERAL System Description Outdoor- - mounted, air - - cooled, split - - system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor , an air- - cooled coil, propeller- - type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract draw ...

メーカー Bryant カテゴリー Air Conditioner

Bryant AIR CONDITIONER WITH PURONR 113Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AIR CONDITIONER WITH PURONR 113Aの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant AIR CONDITIONER WITH PURONR 113Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant AIR CONDITIONER WITH PURONR 113Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant AIR CONDITIONER WITH PURONR 113Aの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant AIR CONDITIONER WITH PURONR 113Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant AIR CONDITIONER WITH PURONR 113Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant AIR CONDITIONER WITH PURONR 113Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant AIR CONDITIONER WITH PURONR 113Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant AIR CONDITIONER WITH PURONR 113Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant AIR CONDITIONER WITH PURONR 113Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant AIR CONDITIONER WITH PURONR 113Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant AIR CONDITIONER WITH PURONR 113Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant AIR CONDITIONER WITH PURONR 113Aデバイスの基本機能を使うにあたってのヒント。 Bryant AIR CONDITIONER WITH PURONR 113Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant AIR CONDITIONER WITH PURONR 113Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant AIR CONDITIONER WITH PURONR 113Aのメーカー/サービスへの連絡先に関する情報。

Bryant AIR CONDITIONER WITH PURONR 113Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant AIR CONDITIONER WITH PURONR 113Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant AIR CONDITIONER WITH PURONR 113Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)