Sharp CV-P12PXの取扱説明書

34ページ 5.2 mb
ダウンロード

ページに移動 of 34

Summary
  • Sharp CV-P12PX - page 1

    PORT ABLE TYPE ROOM AIR CONDITIONER INST ALLA TION AND OPERA TION MANUAL ACONDICIONADOR DE AIRE P ARA HABIT ACIÓN TIPO PORTÁTIL MANUAL DE INST ALACIÓN Y FUNCIONAMIENT O * Plasmacluster is a trademark of SHARP Corporation. * Plasm aclust er es una mar ca re g - ist rad a d e S HAR P Corpor ation. ENGLISH ESP AÑOL CV -P12PX CV -P13PX CV -PD13PX C ...

  • Sharp CV-P12PX - page 2

    CV-P13PX_eng.indd 2 09.1.26 3:36:13 PM ...

  • Sharp CV-P12PX - page 3

    ENGLISH ENGLISH This manual explains the proper use of your new air conditioner . Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CON TEN TS • FOR CUSTOMER ASSIST ANCE (U.S.) ................................. E-2 • CONSUMER LIMITED W ARRANTY (U.S.) ..................... ...

  • Sharp CV-P12PX - page 4

    E-2 FOR CUST OMER ASSIST ANCE (th e Uni ted State s) T o aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit. MODEL NUMBER SERIAL NUMBER DA TE OF PURCHASE Dealer Name Address City State Zip T elephone TO PHONE: Dial 1-800-BE-SHARP (23 ...

  • Sharp CV-P12PX - page 5

    ENGLISH E-3 CONSUMER LIMITED W ARRANTY TO OBT AIN SUPPL Y , ACCESSORY OR PRODUCT INFORMA TION, CALL 1-800-BE-SHARP , OR VISIT OUR WEBSITE A T www .sharpusa.com SHARP ELECTRONICS CORPORA TION Sharp Plaza, Mahwah, New Jersey 07430-2135 CONSUMER LIMITED W ARRANTY FOR THE U.S. USERS SHARP ELECTRONICS CORPORA TION warrants to the rst consumer purchas ...

  • Sharp CV-P12PX - page 6

    PRE CAU TIO NS Points to keep in mind when using your air conditioner . W ARNINGS FOR USE • Install the air conditioner in accordance with the installation instructions in the latter section of this manual. • Do not modify any part of this product. • Do not insert anything into any part of the unit. • Ensure the power supply used has an app ...

  • Sharp CV-P12PX - page 7

    ENGLISH E-5 USAGE CAUTIONS • V entilate the room periodically during use, especially if using gas appliances. • Be sure to turn the unit off and disconnect the power supply cord before performing any mainte - nance or cleaning. • Do not splash or pour water directly onto the unit. W ater can cause electrical shock or equipment damage. • Dra ...

  • Sharp CV-P12PX - page 8

    MIN.12" (30cm) MIN.12" (30cm) PRE CAU TIO NS E-6 OPERA TING CONDITIONS • The air con ditioner mu st be oper ated w ithin the t emperature range indic ated below . MODE Room temperature Cool 64°F ~ 95°F Dehumidication 59°F ~ 95°F • A built-in safety device may cut off operation if the temperat ure exceeds these limits. • When ...

  • Sharp CV-P12PX - page 9

    ENGLISH E-7 INCLUDED CV -P12PX / CV -P13PX Exhaust hose 1 Rain deector assembly 1 W asher 4 Window exhaust adapter 1 Window slider bracket 2 Bolt 4 Exhaust hose adapter A 1 Foam seal A 1 Nut 4 Exhaust hose adapter B 1 Foam seal B (adhesive type) 1 Split-ring washer 4 Bracket 1 Protective screen 1 Manual 1 Window panel assembly 3 Large wood screw ...

  • Sharp CV-P12PX - page 10

    P A RT N AME S 1 Air Outlet 2 V e rtica l louv ers 3 Horizontal louvers 4 POWER Button 5 Remote control signal rece iver window 6 OPER A TI ON La mp (re d) 7 TIMER Lamp (ora nge) 8 MEGA COOL Lamp (green) 9 PLAS MACLUS TER Lamp (blue) 0 Air inlet REAR VIEW NOTE: Actual unit might vary slightly from above illustration. FRONT VIEW q Exha ust ai r out ...

  • Sharp CV-P12PX - page 11

    ENGLISH REM OTE CON TROL 1 T r ansmit ter 2 Disp lay 3 POWER Button 4 LIGHTS Button 5 TEMPE RA TURE Butt on 6 PLAS MACLUS TER B utton 7 SLEEP Button 8 MODE Butto n 9 ON TI MER B utton 0 F A N Butt on q OFF TIMER Button w CANC EL Button e LOUVERS Button r RESE T Butt on t MEGA COOL Button E-9 y MODE SYMBO LS : COOL : DEHUMIDIFICA TION : F AN : VENTI ...

  • Sharp CV-P12PX - page 12

    1 Cut th e foam seal A t o the pr oper le ngth and attach it to the window stool. 2 Atta ch the w indow ex haust a dapter t o the window panel inside opening. 3 Attach the pro tective screen to the outside of the window exhaust adapter . Use 2 screws to attach the protect ive screen onto the outside of the window exhaust adapter . 4  Inst all ...

  • Sharp CV-P12PX - page 13

    ENGLISH If the inner width of the window is between 28" (718mm) and 36.5" (927mm) inclusive. (1 ) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to t the window frame width. (3) Sec ur e th e w in do w pa ne l t o t he s to ol with 3 large wood screws. If the inner width of the windo ...

  • Sharp CV-P12PX - page 14

    1 Cut th e foam seal A t o the pr oper le ngth and attach it to the window stool. 2 Attach 2 window exhaust adapters to the window panel inside opening. 3 Attach 2 protective screens to the outside of the window exhaust adapter . Use 4 screws to attach the protect ive screens onto the outside of the window exhaust adapter . 4  Insta ll 2 r ...

  • Sharp CV-P12PX - page 15

    ENGLISH If the inner width of the window is between 28" (718mm) and 36.5" (927mm) inclusive. (1 ) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to t the window frame width. (3) Sec ur e th e w in do w pa ne l t o t he s to ol with 3 large wood screws. If the inner width of the windo ...

  • Sharp CV-P12PX - page 16

    1 Cut the foam seal A to the proper length and attach it to the window frame. 2 Atta ch the window exhau st ada pter t o the window panel inside opening. 3 Attach the pro tective screen to the outside of the window exhaust adapter . Use 2 screws to attach the protective screen onto the outside of the window exhaust adapter . 4  I nstal l the? ...

  • Sharp CV-P12PX - page 17

    ENGLISH I f t h e i n n e r h e i g h t o f t h e w i n d o w i s between 28" (718mm) and 36.5" (927mm) inclusive. (1 ) Open the window sash and place the window panel on the window frame. (2) Slide the adjustment panel to t the window frame height. (3) Secure th e window panel to the window frame with 3 large wood screws. If the inner ...

  • Sharp CV-P12PX - page 18

    1 Cut the foam seal A to the proper length and attach it to the window frame. 2 Attach 2 window exhaust adapters to the window panel inside opening. 3 Attach 2 protective screens to the outside of the window exhaust adapter . Use 4 screws to attach the protective screens onto the outside of the window exhaust adapter . 4  Insta ll 2 rain? ...

  • Sharp CV-P12PX - page 19

    ENGLISH I f t h e i n n e r h e i g h t o f t h e w i n d o w i s between 28" (718mm) and 36.5" (927mm) inclusive. (1 ) Open the window sash and place the window panel on the window frame. (2) Slide the adjustment panel to t the window frame height. (3) Secure th e window panel to the window frame with 3 large wood screws. If the inner ...

  • Sharp CV-P12PX - page 20

    Installation of the exhaust hose (CV -P12PX, CV -P13PX) 1 Attach the exhaust hose adapters A and B to the exhaust hose. Extend both ends of the exhaust hose and insert them into the exhaust hose adapters A and B respectively , and turn them until they stop. Make sure they are securely attached. 2 Attach the exhaust hose adapter B to the unit. Inser ...

  • Sharp CV-P12PX - page 21

    ENGLISH Installation of the exhaust hose (CV -PD13PX) 1 Attach the exhaust hose adapters A and B to the exhaust hoses. Extend both ends of the exhaust hose and insert them into the exhaust hose adapters A and B respectively , and turn them until they stop. Attach the other exhaust hose adapters A and B to the exhaust hose in the same way . Make sur ...

  • Sharp CV-P12PX - page 22

    NOT ICE: If the dual -duct typ e u nit is used as sin gle-d uct type one , pl ease ref er to the follo w- ing instructions: 1 Attach the grille and the cover to the unit. Open the bafe and remove it. Insert the 2 projections on the grille into the 2 holes on the back plate of the unit, and close the grille. Ins ert t he t wo pr oject ions on t h ...

  • Sharp CV-P12PX - page 23

    ENGLISH Removal of the exhaust hose 1 Remove the exhaust hose adapter A. Remove the exhaust hose adapter A from the window exhaust adapter . 2 Remove the exhaust hose adapter from the unit. Lift up and remove the ex haust hose adapter from the unit by pushing down on the two projections. Projection E-2 1 Exhaust hose adapter A Window exhaust adapte ...

  • Sharp CV-P12PX - page 24

    E-2 2 NOTES: • The battery should last approximately one year under normal use. • When replacing the batteries, always change both batteries at the same time, and make sure they are the same type. • If the remote control does not operate normally after replacing the batteries, press the RESET button using a thin pointed implement. • If you ...

  • Sharp CV-P12PX - page 25

    ENGLISH E-2 3 CAUTION • Do not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary , close the curtains to block out the sunlight. • Use of a uorescent lamp in the same room may interfere with transmission of the signal. • The unit may be affected by signals emitted from other remote ...

  • Sharp CV-P12PX - page 26

    E-2 4 COOL MODE Ensure that the stopcock is securely attached the drainpipe. 1 Pres s the MODE button to select COOL mode . COOL DEHUM FAN VENT 2 Pres s t he POWER butto n t o s tart opera - tion. • The red OPERA TION lamp on the unit will light. 3 Press the TEMPERA TURE button to set the desired temperature. • The temperature can be set within ...

  • Sharp CV-P12PX - page 27

    ENGLISH E-2 5 F AN MODE VENTILA TION MODE 2 1 3 2 1 3 In this mode, the air conditioner simply circulates the a ir without cooling it. In this mode, the air conditioner ventilates the air to outdoor s. 1 Pres s the MODE butto n to s elect F A N mod e. COOL DEHUM F AN VENT 2 Press the POWER button to start operation. • The red OPERA TION lamp on t ...

  • Sharp CV-P12PX - page 28

    T O CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION NOTE • During VENTILA TION mode, UP/DOWN air ow direction cannot be changed. Hold the vertical louver as shown in the dia- gram and adjust the air ow direction. 1 Press th e L OUVER S b utton on the re- mote control. • The horizontal louvers will swing continu- ously . 2 Press the ...

  • Sharp CV-P12PX - page 29

    ENGLISH E-2 7 1 Press the PLASMACLUSTER button during oper ation. • The remote control will display “ ”. • The blue PLASMACLUSTER lamp on the unit will light. TO CANC EL Pres s the PLASM ACLUS TER b utton again . • The PLASMACLUSTER lamp on the unit will turn off. NOTE S: • Use of the PLASMACLUSTER function will be memorized and it will ...

  • Sharp CV-P12PX - page 30

    1 Press the MEGA COOL button during cooling mode. • The remote control will display " " . • The temperature display will go off. • The green MEGA COOL lamp on the unit will light. TO CANCEL Press the MEGA COOL button again. • MEGA COOL operation is also cancelled when the mode is changed, or when the unit is turned off. • The gr ...

  • Sharp CV-P12PX - page 31

    ENGLISH 0.5h 1.0h 1.5h 10h 1 1h 12h ON TIMER 1 Press the ON TIMER button. • The time setting will change as you press the button as follows. Hold the button down to speed through the settings. • The orange TIMER lamp on the unit will light. • The time setting will coun t down to show the remaining time. TO CANCEL TIMER Pres s the CANC EL butt ...

  • Sharp CV-P12PX - page 32

    Prepare for drainage and drain out water within the unit in the following cases. • When the unit stops operating and the TIME R, OPERA TION and MEGA COOL lamps are blinking, the water tank is full and need to be drained. • When the unit is not used for a long time. 1 Unplug the power plug and move the unit to a drain or outside. 2 Remove the st ...

  • Sharp CV-P12PX - page 33

    ENGLISH E-3 1 CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them with a soft, dry cloth or with a cloth moistened with a mild soap. Carefully remove any residue by wiping with a damp cloth and dry completely . Avoid splashing water onto the unit. W ater can dangerously damage the electrical insulation. Never use harsh chemicals or abrasive cleaners ...

  • Sharp CV-P12PX - page 34

    BEFORE CALLING FOR SER VICE If the unit appears to be malfunctioning, check the following points before calling for a service. AIR CONDITIONER DOES NOT OPERA TE A T ALL • Is the unit plugged in or is the plug loose? • Has the fuse blown or is the circuit breaker tripped? • Did you restart the unit within 3 minutes of a power failure? If the p ...

メーカー Sharp カテゴリー Air Conditioner

Sharp CV-P12PXのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CV-P12PXの取扱説明書
- Sharpの製品カード
- パンフレット
- またはSharp CV-P12PXの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sharp CV-P12PXの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sharp CV-P12PXの取り付け説明書、サービスマニュアル、簡易説明書、またはSharp CV-P12PXのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sharp CV-P12PXの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sharp CV-P12PXデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSharp CV-P12PXを使用するのを助ける技術的文書のことです。説明書は通常、全てのSharp CV-P12PXユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sharpの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sharp CV-P12PXの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSharp CV-P12PXの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sharp CV-P12PXに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sharp CV-P12PXデバイスの基本機能を使うにあたってのヒント。 Sharp CV-P12PXのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sharp CV-P12PXに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSharp CV-P12PXのメーカー/サービスへの連絡先に関する情報。

Sharp CV-P12PXについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSharp CV-P12PXの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSharp CV-P12PXで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)