Graco 313386Dの取扱説明書

42ページ 2.39 mb
ダウンロード

ページに移動 of 42

Summary
  • Graco 313386D - page 1

    313386D EN Softw are Instr uctions Pr oMix ® 2KS/3KS W eb Interfaces Installation and program setup instructions to allo w comm unication between a PC and the ProMix ® 2KS/3KS Electr onic Proportioner , via an Ethernet. For professional use onl y . Not for use in e xplosive atmospheres. Basic W eb Interface (supplied with Pr oMix 2KS/3KS EasyKe y ...

  • Graco 313386D - page 2

    Related Manua ls 2 313386D Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W a rnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ProMix 2KS/3KS Basic Web Interface (BWI) . . . . . 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 W eb Navigation Screens . . . . . ...

  • Graco 313386D - page 3

    Warnings 313386D 3 Wa r n i n g s The f o llowing w arnings are fo r the setup , use, groundin g, maintenance, and repair of this equipment . The e xclama- tion point symbol ale r ts you to a gener al war ning and the hazard sym bol ref ers to procedure-specific risk. Ref er back to these wa rnings. Additional, pr oduct- specific w arnings may be f ...

  • Graco 313386D - page 4

    ProMix 2KS/3KS Basic Web Interface (BWI) 4 313386D Pr oMix 2KS/3KS Basic W eb Interface (BWI) NO TE: Screen views in this manual ar e shown using Microsoft Windo ws XP . NO TE: The ProMix 2KS/3KS Basic Web Interf ace (BWI) is supplied with all EasyK e ys. T o run the program, J a va V ersion 6 Update 10 (or later) must be loaded on your computer . ...

  • Graco 313386D - page 5

    ProMix 2KS/3KS Basic Web Interface (BWI) 313386D 5 3. Before running the BWI s oftware y ou must manually assign an IP address to y our computer: a. On your comput er , click on the St ar t button to open the men u, then clic k on Control Panel . b. S e e F IG . 2. Doub le clic k on Netw ork Connec- tions. Doub le click on Local Area Connection to ...

  • Graco 313386D - page 6

    ProMix 2KS/3KS Basic Web Interface (BWI) 6 313386D c. I n the Local Area Conne ction Properties win- dow , scroll to Inter n et Protocol ( TCP/IP) and doub le click, t o open the Internet Protocol (TCP/IP) Proper ties window . See F IG . 4. d. See F IG . 4. Set to “Use the f ollowing IP address:” e. T ype in the follo wing IP address: 192.168.1 ...

  • Graco 313386D - page 7

    ProMix 2KS/3KS Basic Web Interface (BWI) 313386D 7 4. On the EasyK ey, go to System Configur ation Screen 5 and write down t he IP numb er assigned to that EasyKe y (1 -99). See F IG . 5. NO TE: V erify that the wire less connection is turned off (disabled) before performing s tep 5. 5. Open Microsoft In ternet Explorer (Star t>All Pro- grams> ...

  • Graco 313386D - page 8

    ProMix 2KS/3KS Basic Web Interface (BWI) 8 313386D W eb Navigation Screens F rom the main BWI screen (see F IG . 7) the operator can select Setup, Software/Resets, or Repor ts. NO TE: Bef ore running the BWI prog ram, chec k the EasyK e y Status scree n to ensure that the syst em is in Standb y . Setup Download setup values - sav es the ProMix 2KS/ ...

  • Graco 313386D - page 9

    ProMix 2KS/3KS Basic Web Interface (BWI) 313386D 9 Downloa d custom langu age - sa v es the current system language to the PC . See F IG . 10. This file is opened and a custom lan guage added to the B column of the Excel file. NO TE: Custom languages are limit ed to Ascii and Ascii e xtended ch aracter s and a maximum of 32 characters . Sav e the E ...

  • Graco 313386D - page 10

    ProMix 2KS/3KS Basic Web Interface (BWI) 10 313386D Reports NO TE: Display material usa ge report - shows the materi al spra yed from the ProMix 2KS /3KS. See F IG . 15. Clear materi al usage repo rt - deletes the mater ial usage from the displa y . Download job log - do wnloads the job log t o the PC . Download err or log - do wnloads the error lo ...

  • Graco 313386D - page 11

    ProMix 2KS/3KS Basic Web Interface (BWI) 313386D 11 Displa y job log - displa ys the job number , date, time , recipe, ratio , targ et, volumes, g rand totals, and any errors that occurr ed during the job . See F IG . 22. Displa y err or log - displa ys the number of alarms, date , time, recipe and what the erro r was. See F IG . 19. Clear job log ...

  • Graco 313386D - page 12

    Install the Advanced Web Interface (AWI) Module 12 313386D Install the Ad v anced W eb Interface (A WI) Module Overview The Graco Advanced Web Interface (A WI) Acces sor y allows communication betw een multiple ProMix 2KS/3KS and a PC o v er an Ethernet, enabling users to monitor the ProMix 2 KS/3KS, vie w and change system setup par ameters , and ...

  • Graco 313386D - page 13

    Install the Advanced Web Interface (AW I) Module 313386D 13 Connect Module to EasyKe y and PC 1. Shut of f ProMix 2KS/3KS p ower (0 position). F IG . 23. Also shut off po wer at main circuit break er . 2. Run a CA T5 cable from the EasyK ey con nector through the g rommet and conn ect it to an y por t in the A WI module. Connect an other CA T5 ca b ...

  • Graco 313386D - page 14

    Install the Advanced Web Interface (AWI) Module 14 313386D F IG . 25: ProMix Network T ypical Installation TI13065a EasyK e ys A WI Master Module Computer Use CA T5 cables f or connections. AW I H u b ...

  • Graco 313386D - page 15

    Install the Advanced Web Interface (AW I) Module 313386D 15 F IG . 26: LAN Network (Manual) T ypical Installa tion TI13064b EasyK ey EasyK ey LAN Networ k AW I M o d u l e Computer Computer Inter net (via VPN) Use CA T5 cables f or connections . NO TE: LAN Networ k (Manual) Installation requires co mpletion of the procedur es on pages 16 -20 before ...

  • Graco 313386D - page 16

    Computer Configuration 16 313386D Computer Configuration Set up an A utoma tic IP Address See F IG . 27. O n your computer , go to Contr ol P anel>Network Connection s>Local Area Connec- tion>Proper ties>Inte rnet Protocol (T CP/IP). V erify th at “Obtain an IP address autom atically” is selected in the TCP/IP Proper ties window . I ...

  • Graco 313386D - page 17

    Computer Configurati on 313386D 17 4. The Welcome screen will appear . See F IG . 29. Click Ne xt. 5. The Security screen will appear . See F IG . 30. The administrator must fill in all fields . Click Ne xt. 6. Initialization is complete. See F IG . 31. Click Finish. 7. The Login screen will appear . See F IG . 32. T ype in the login name and pass ...

  • Graco 313386D - page 18

    Computer Configuration 18 313386D P assw or d Recovery 1. If you type in the wrong pass word, sign in will be bl oc ke d. See F IG . 33. Clic k on the bloc k icon to initiate the pass word recov er y sequence. 2. See F IG . 34. The system will prompt you f or y our login name . T ype in the name you entered in step 5 on page 17, then click Ne xt. 3 ...

  • Graco 313386D - page 19

    Computer Configurati on 313386D 19 Set the Netw ork Configuration ProMix 2KS/3KS Netw ork Configuration In a ProMix 2KS/3KS network, the A WI module is con- nected to a n EasyK ey and a persona l computer . Up to 100 EasyK eys ma y be connected in the netw ork. See F IG . 25. T o select a ProMix 2KS/3KS netw ork, go to the Settings tab and select P ...

  • Graco 313386D - page 20

    Computer Configuration 20 313386D LAN Network (Man ual) Configuration See F IG . 26. A LAN network (man ual) configur ation enables you to work thro ugh a local network . Up to 100 EasyK e ys ma y be connected in the ne twork. The EasyK e ys and A WI Module mus t be on the same sub- network. The EasyK eys can be connected to an y LAN drop. NO TE: T ...

  • Graco 313386D - page 21

    AWI Screens 313386D 21 AW I S c r e e n s This section describes how to use the A WI screens to access and make changes to system settings and reci- pes. F or complete inf ormation about these settings and their eff ects, see the Setup se ction in the system oper a- tion manual. Netw ork T ab Use the Network tab to select the de sired EasyK ey. See ...

  • Graco 313386D - page 22

    AWI Screens 22 313386D Materials T ab Use the Materials tab to enter inf or mation on V olatile Components (V OC) and Hazardous Air P ollutants (HAP) f or each material being used in y our system, f or material repor ting. This inf or mation, and the manuf acturer’ s par t no ., are av ailable on the MSDS shee t prov ided b y the material manuf a ...

  • Graco 313386D - page 23

    AWI Screens 313386D 23 ...

  • Graco 313386D - page 24

    AWI Screens 24 313386D Settings T ab Use the Settings tab t o configure the main system set - tings (Time , Language, Upg r ade A WI, and Edit Accounts). NO TE: F IG . 41 shows the Set tings screen when y ou log in as a us er . F IG . 42 shows the Settings screen when yo u log in as a system administr ator . Set Time T o synchronize the time set ti ...

  • Graco 313386D - page 25

    AWI Screens 313386D 25 Edit Account Inf ormation NO TE: Account inf or mation can only be entered by a system adminis trator . See F IG . 42. • T o add a new account, click the Add User but - ton. Enter the inf ormatio n in the data fields. Click . A checkmark ( ✓ )will appear in the top right cor ner when th e sav e is complete. • T o edit a ...

  • Graco 313386D - page 26

    AWI Screens 26 313386D System Setup Screens T o view the system set up screens , go to th e Network tab and clic k on the desired EasyK ey to acce ss the setup screens f or that de vice. See F IG . 43. Monitor T a b Select the Mon itor tab to view data from the EasyKe y Status screen, in real time . See F IG . 44. F IG . 43. Open De vice Click on d ...

  • Graco 313386D - page 27

    AWI Screens 313386D 27 Material Setup T ab Go to the Ma terial Setup tab to a ssign a catalyst , color , reducer (on 3 KS) and flush material f or the v alv es of the activ e de vice , using the pulldo wn menus . F or 2KS , each de vice may include up to 30 color v alv es , 4 catalyst v alv es, and solv ent flush valv es. F or 3KS , each de vice ma ...

  • Graco 313386D - page 28

    AWI Screens 28 313386D System Setup T ab The Setup tab has three edit able screens: •T h e Configuration screen correspon ds to the Sys- tem Configur ation screens of the EasyK ey. See F IG . 46. F o r complete inf or mation about these set tings and their eff ects, see the Setu p section in the sys- tem oper ation man ual. •T h e Adv anced scr ...

  • Graco 313386D - page 29

    AWI Screens 313386D 29 F IG . 47. Syste m Setup T ab, Adv anced Screen F IG . 48. System Setup T a b, Recipe Screen Click to create a recipe timing char t. See F IG . 49. 1.0 2.0 ...

  • Graco 313386D - page 30

    AWI Screens 30 313386D F IG . 49. Sample Recipe Timing Chart ...

  • Graco 313386D - page 31

    AWI Screens 313386D 31 Reports T ab The Repor ts tab enab les y ou to produce thre e repor ts: • Material Repor t •J o b R e p o r t • Alarm Repor t Select which of the thre e repor ts yo u want to cre ate. Click the desired output f or mat f or th e repor t: • CSV (can be impor ted into Microsoft Excel). • TXT (straight text). Click the ...

  • Graco 313386D - page 32

    AWI Screens 32 313386D Job Report See F IG . 51. The Job Rep or t provides detaile d inf or ma- tion on all completed jobs within a designated time peri od. Select the inf or mation desired by clicking on the bo x to the left of each par ameter . Set the time frame b y using the Calendar b uttons to the r ight of each date box. NO TE: The dates use ...

  • Graco 313386D - page 33

    AWI Screens 313386D 33 Alarm Report See F IG . 52. The Alarm Repor t lists all alarms tr iggered within a designated ti me period. Set the time frame b y using the Calendar b uttons to the right of each date bo x. NO TE: The dates use the day/month/year forma t. F IG . 52. Alarm Report Screen ...

  • Graco 313386D - page 34

    AWI Screens 34 313386D Level Contr ol T ab See F IG . 53. Th e Lev e l Control T ab allows you to input the supply tank v olume of the materials and th e le v el at which an alarm should be triggered. The alarm function ma y be turned on or off f or each material v alv e. F IG . 53. Level Contr ol T ab ...

  • Graco 313386D - page 35

    AWI Screens 313386D 35 Sidebar See F IG . 54. The Sidebar relates t o the EasyKe y being monitored. It has four links to related s creens: • Sav e - sav es the current de vice configur ation into a file. • Restore - restores config urations of th e de vice from a file. • Cop y (Sync Settings)- co pies the configura tion of this de vice into o ...

  • Graco 313386D - page 36

    Replace AWI Board 36 313386D Replace A WI Board 1. Shut of f ProMix 2KS/3KS p ow er (0 positio n). 2. Shut of f power at main circuit breaker . 3. Open the A WI module . 4. Disconnect the cab le (15) and wires (17, 18) from the board (22). F IG . 5 5. 5. Remove the screws (21) and bo ard (22). 6. Install the ne w board. Reconnect the cab le (15) an ...

  • Graco 313386D - page 37

    Replace AWI Board 313386D 37 ...

  • Graco 313386D - page 38

    Parts 38 313386D Pa r t s 15V337 Adv anced W eb Interface Module P ar ts labeled n/a are not av ailable separately . TI12926a TI12927a TI12928a 3 4 56 8 10 11 12 13 4 15 17 18 17 18 18 18 17 17 21 22 10 22 7, 9, 12 1, 2 To 4 To 2 2 To 1 0 Wiring Diagrams 5 +24 COM To 4 +24 COM +24 COM V1+ V1- P ower Supply Wiring Det ail L1+ NC NC N - OUT - - DC - ...

  • Graco 313386D - page 39

    Parts 313386D 39 15V336 Adv anced W eb Interface Ser ver Hub P ar ts labeled n/a ar e not a va ilab le separatel y . +24 COM V1+ V1- TI13204a TI13206a TI13205a 3 4 56 8 10 11 12 13 17 18 18 17 10 7, 9, 12 1, 2 To 4 To 1 0 Wiring Diagrams 54 Screw Location (item 28) Ref. No. P art No. Description Qty 1 15V339 P AN EL, back 1 2 15T752 CO VER 1 3 n/a ...

  • Graco 313386D - page 40

    Electrical Schematic 40 313386D Electrical Schematic Non-Hazar dous Area DISPLA Y BOARD 1 2 3 4 J9 1 2 3 4 5 6 7 8 9 10 11 J4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DISPLA Y MEMBRANE SWITCH WITH RIBBON CABLE 1 2 3 4 5 6 J10 1 2 3 4 5 6 7 8 9 10 J5 J7 J8 RJ45 RJ45 RJ45 RJ45 P1 J6 WEB SERVER MODULE RJ45 RJ45 J2 3' (25'-200' ...

  • Graco 313386D - page 41

    Dimensions 313386D 41 Dimensions TI12825b 16.57 in. (420.9 mm) 15.07 in. (382.8 mm) 6.45 in. (163.8 mm) 5.31in. (134.9 mm) 8.71in. (221.2 mm) TI12926a ...

  • Graco 313386D - page 42

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. Thi s manual contains Eng lish. MM 313386 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Kor ...

メーカー Graco カテゴリー Network Router

Graco 313386Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 313386Dの取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 313386Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 313386Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 313386Dの取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 313386Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 313386Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 313386Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 313386Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 313386Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 313386Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 313386Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 313386Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 313386Dデバイスの基本機能を使うにあたってのヒント。 Graco 313386Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 313386Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 313386Dのメーカー/サービスへの連絡先に関する情報。

Graco 313386Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 313386Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 313386Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)