    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info FMG90 Series Electromagnetic Flow Meter Shop online at U ser ’ s Guide ...

  • Omega Engineering FMG90 - page 2

    ...

  • Omega Engineering FMG90 - page 3

    Table of contents page 1 About this oper ating m anual.................................................................................... 4 2 Device descr iption ................................................................................................... 5 2.1 Intended us e ................................................................... ...

  • Omega Engineering FMG90 - page 4

    1 About this operating manual • The operating manual is aimed at specialists and semi-skilled personnel. • Before each step, read through the relevant adv ice carefully and keep to the specified order. • Thoroughly read and understand the information in the section (Safety Instructions " 3 " ). If you have any problems or questions, ...

  • Omega Engineering FMG90 - page 5

    2 Device description The FMG90 series from Omega, is a non-c ontact flow sensor. The measurement is performed using magnetic induction and works without any moving parts. The FMG90 is used for measuring or metering water and aqueous solutions. The compact design and independence from the intake and disc harge sections allows the FMG90 to be used un ...

  • Omega Engineering FMG90 - page 6

    2.1 Intended use The magnetic inductive flow sensor FMG90 mu st only be used for measuring and metering liquids with a minimum conductivity of 20 μ S/cm. WARNING! No safety component! The magnetic inductive flow sensor of the series FMG90 are not safety components in accordance with Directive 2006-42-EC (Machine Directive). ª Never use the FMG90 ...

  • Omega Engineering FMG90 - page 7

    3 Safety instructions Before you install the FMG90, read through this operating manual carefully. If the instructions contained within it are not follow ed, in particular the safety guidelines, this could result in danger for people, the envir onment, and the device and the system it is connected to. The FMG90 correspond to the state-of-the-art te ...

  • Omega Engineering FMG90 - page 8

    4 Construction and function Construction: The measuring tube with its ear thing sleeves and electrodes passes through the sensor housing and forms the external process connection of the FMG90. A magnetic field for the measur ement process is generated inside the sensor housing, which also contains the sensor and signal conditioning circuitry. The t ...

  • Omega Engineering FMG90 - page 9

    5.1 Installation instructions CAUTION! Risk of malfunction due to external magnetic fields! Magnetic fields close to the device can cause malfunctions and should be avoided. ª Ensure that no external magnet ic fields are present at the installation site of the FMG90. • The FMG90 can always be installed anywhere along the pipeline. Straight secti ...

  • Omega Engineering FMG90 - page 10

    • If two or more FMG90 devices are used side by side, maintain a separation of at least 2.5 cm between adjacent devices. If adjacent devices are too cl ose together, operation of both devices may be impaired due to mutual interference. 5.2 Assembly The FMG90 is installed directly into the pipe line. The compact design and light weight of the unit ...

  • Omega Engineering FMG90 - page 11

    6 Electrical connection The electrical connection of the FMG90 is via the 4-pin plug M12x1 at the top. The corresponding connection cables with moulded coupling socket are available in various lengths. CAUTION! Electric current! The electrical connection should only be carried out by a fully qualified electrician. ª De-energize the electrical syst ...

  • Omega Engineering FMG90 - page 12

    7 Commissioning and measuring operation Before switching on the FMG90 for the first time , please follow the instructions in the following section. 7.1 Commissioning Check that  the FMG90 has been installed correctly and that all screw connections are sealed.  the electrical wiring has been connected properly.  the measuring system is vent ...

  • Omega Engineering FMG90 - page 13

    9 Disassembly and disposal CAUTION! Risk of injury! Never remove the device from a plant in operation. ª Make sure that the plant is shut down professionally. Before disassembly: Prior to disassembly, ensure that  the equipment is switched off and is in a safe and de-energised state.  the equipment is depressurised and has cooled down. Disas ...

  • Omega Engineering FMG90 - page 14

    10 Technical data The technical data of customised versions may differ from the data in these instructions. Please observe the information specified on the type plate. Type FMG 91 FMG 92 FMG 93 FMG 94 FMG 95 FMG 96 Measurement device characteristics Flow range [GPM] 0.066…1.3 0.26…5.3 0.66…13. 2 1.3…26.4 2.6…53 3.3…66 Accuracy 1% of rea ...

  • Omega Engineering FMG90 - page 15

    10.1 Materials table Component Material Component- w etted Sensor housing ABS Measuring tube PVDF X Process connections PVDF X O-ring EPDM X Electrodes Stainless steel 316L X Grounding rings Stainless steel 316L X 10.2 Pressure drop FMG 91 / FMG 92 FMG 91 / FMG 92 FMG 93 FMG 93 FMG 94 / FMG 95 FMG 94 / FMG 95 FMG 96 FMG 96 ...

  • Omega Engineering FMG90 - page 16

    10.3 Dimensions FMG 91 - 95 Ty pe L1 L2 D1 D2 FMG 91 4± 0.02 0.83 ± 0.01 ½ - 14 NPT Ø 0.31 FMG 92 4± 0.02 0.83 ± 0.01 ½ - 14 NPT Ø 0.31 FMG 93 4.02± 0. 02 0.83± 0.01 ¾ - 14 NPT Ø 0.55 FMG 94 4.41± 0. 02 0.98± 0.01 1 – 11.5 NPT Ø 0.71 FMG 95 4.41± 0. 02 0.98± 0.01 1 – 11.5 NPT Ø 0.71 FMG 96 ...

  • Omega Engineering FMG90 - page 17

    ...

  • Omega Engineering FMG90 - page 18

    M-5204/1112 ...

メーカー Omega Engineering カテゴリー Oxygen Equipment

Omega Engineering FMG90のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FMG90の取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering FMG90の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering FMG90の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering FMG90の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering FMG90のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering FMG90の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering FMG90デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering FMG90を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering FMG90ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering FMG90の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering FMG90の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering FMG90に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering FMG90デバイスの基本機能を使うにあたってのヒント。 Omega Engineering FMG90のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering FMG90に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering FMG90のメーカー/サービスへの連絡先に関する情報。

Omega Engineering FMG90についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering FMG90の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering FMG90で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)