ResMed NOT014224-2の取扱説明書

35ページ 6.38 mb
ダウンロード

ページに移動 of 35

Summary
  • ResMed NOT014224-2 - page 1

    FRONT OF DEVICE Components of the NOT014224-2 System REAR VIEW - SIDE VIEW VS Ultra™ & VS Integra™ COMPONENTS Illustrations ACCESSORIES View from above Rear view External battery (optional) Side view Coupling for oxygen socket (optional) Circuit connection area D C B A © 20 07 ResMed Ltd. © 20 07 ResMed Ltd. © 20 07 ResMed Ltd. © 20 07 ...

  • ResMed NOT014224-2 - page 2

    CONNECTING THE ACCESSORIES Option 1 - Single circuit Option 3 - Double circuit External battery Plug for supplemental oxygen Option 2 - Single circuit with expiratory valve and pressure line connector SETTING UP THE DEVICE CONNECTING TO POWER SUPPLY E F CONNECTING THE CIRCUIT CONNECTING THE CIRCUIT F (a) SWITCHING ON (AND SHUTTING DOWN) G H © 20 0 ...

  • ResMed NOT014224-2 - page 3

    VS Ultra™ & VS Integra™ P atient manual English NOT014224-2 07 10 ...

  • ResMed NOT014224-2 - page 4

    ResMed Schweiz AG Viaduktstrasse Basel, Switzerland, +41 61 564 70 00 or 0800 00 2500 (toll free). Saime SAS (Manufacturer), Savigny-le-T emple, France. ResMed Corp Poway , CA, USA +1 858 746 2400 or 1 800 424 0737 (toll free), ResMed Ltd Bella Vista, NSW , Australia, +61 (2) 8884 1000 or 1 800 658 189 (toll free). Offices in Austria, Brazil, Chin ...

  • ResMed NOT014224-2 - page 5

    iii Cont ents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 .1 Definitions 1 1 .2 User/O wner Responsibility 1 1 .3 Medical Inf ormation 1 2 Description of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1 Components 3 2.2 Y our de vice 4 2.3 Circuit 8 2.4 Accessories 8 2.5 D ...

  • ResMed NOT014224-2 - page 6

    1 Introduction 1 Introduction This manual is provided with the device you have received, a medical ventilator in the VS range. I t does not in any way replace the clinical manual supplied to your physician or HME provid er. There are two mode ls: • the VS Ultra™, whic h is blue • the VS Integra™, whic h is re d . These devices are designed ...

  • ResMed NOT014224-2 - page 7

    2 The VS Integra and V S Ultra can both be used with single circuit, but only the VS Ultra model can be used with double circuit. Warnings • This manual mu st be read and understo od in full bef ore the de vice is used. • The advice contained in this manual does n ot replace the instr uctions given b y your ph ysician (or HME provider), who wil ...

  • ResMed NOT014224-2 - page 8

    3 Description of the devic e 2 Description of the device 2.1 Components The picture below sh ows the set of compon ents available from yo ur HME provide r: • Y our de vice • The po w er cable • The circu it • An interf ace (mask or trac heotomy) • The trav el bag . Figure 1: Components availa ble from your HME provider. 1 2 3 4 5 ...

  • ResMed NOT014224-2 - page 9

    4 2.2 Your device Front view The device comprises: • A control pane l • An area for connecting the circuit . Figure 2: Front vi ew of the device. The control panel comprise s a screen and a keypad. Figure 3: Device control pa nel. 1 2 LCD Screen Ke ypad ...

  • ResMed NOT014224-2 - page 10

    5 Description of the devic e The circuit connection area comprises: • An air outlet • Single circuit suppo rt w ith e xhalation and pressure lin e connection . Figure 4: Detailed view of single circuit support wi th exhalation and pressure line connecti on. There is a differen t type of circuit suppor t for double circuit ( see next Figure). Ai ...

  • ResMed NOT014224-2 - page 11

    6 Figure 5: Detailed view of co nnection fo r a double circuit. Rear view On the rear of the device, take part icular note of the location of the following: • The p ow er supply soc ket • The f astening clip for the po wer connection • The anti-dust filter . Y ou will ha ve to replace this filter (see “Cleaning and Main tenance ” on page ...

  • ResMed NOT014224-2 - page 12

    7 Description of the devic e Figure 6: Rear view of de vice. Side view Some device mo dels are fitted with a metal co nnector for attaching an oxygen supply (see next Figure). For instructions on connecting the ox ygen source to the de vice, see “Connecting supplement al oxygen (option al)” on page 18. Figure 7: Metal connector for optional O2 ...

  • ResMed NOT014224-2 - page 13

    8 2.3 Circuit Depending on the ventilati on mode prescribed by your physician, you will be using on e of the f ollowing: • Single circuit • Single circu it with e xpirator y valv e • Double circuit To determine the t ype of circuit prescribed fo r you and how to connect it to the device, see “Co nnecting the circu it” on page 12. 2.4 Acce ...

  • ResMed NOT014224-2 - page 14

    9 Description of the devic e External battery (optional) An ex te rna l ba tte r y increas es the utilisation period away from a mains power supply, and also provides a back-up supply in the event of a power outage. This accessory comprises: • The exte rnal bat ter y , at t ac hed to its holder • The cable connecting the de vice to the e xterna ...

  • ResMed NOT014224-2 - page 15

    10 2.5 Device control panel The device control panel compri ses an LCD screen and a keypad. Figure 10: Front view. The buttons on the keypad are listed in the table below. The keypad consists of buttons and LED indicator lights. T able 1: Buttons on device control p anel. Button F unction On/Of f but ton Used to switc h the device on and of f . Ala ...

  • ResMed NOT014224-2 - page 16

    11 Connection procedures 3 Connection procedures Place the device on a flat surface. En sure the area is du st-free, and cleared of any objects that could blo ck the dust filt er. ! CAUTION Be careful not to place the device where it co uld be knocked over or where someone is likely to trip over the power cord. 3.1 Connecting to a power supply 1 . ...

  • ResMed NOT014224-2 - page 17

    12 Not es: • If you r device is fit ted with a rec hargeable built-in bat ter y (available as an optional e xtra with the VS Integra), it can be used without a mains pow er supply , with the bat ter y lasting 2 – 4 hours , depending on yo ur set tings. • The bat ter y rec harges au tomatically when the de vice is connected to the mains supply ...

  • ResMed NOT014224-2 - page 18

    13 Connection procedures Option 1 – Single circuit 1 . Connect one end of the hor izontally -ribbed t ube firmly to t he air outlet, as sho wn in the Figure below : Figure 12: Connection of single circuit to the device . Now that y our circuit is connect ed to the device, y ou can connect the mask to the other end of the circuit. Option 2 – Sin ...

  • ResMed NOT014224-2 - page 19

    14 Figure 13: Connectio n of single circuit with expi ratory valve and pressure line. See the next Figure for a detail ed view of the connection panel. Figure 14: Detailed view of circuit connection s to the single circuit support. 1 2 3 Pressure line t ube Expirator y valve t ube 2 3 Expirator y valve control Pressure line P ...

  • ResMed NOT014224-2 - page 20

    15 Connection procedures Now that y our circuit is connect ed to the device, y ou can connect the mask to the other end of the circuit. Option 3 – Double circuit 1 . Firmly connect on e limb of the circuit to the air outlet . 2. Then connect th e other limb . Figure 15: Connection o f a double circuit. Not e: In most cases, your circuit co nfigur ...

  • ResMed NOT014224-2 - page 21

    16 3.4 Example of fu lly-assembled system Figure 16: Example of fully-assemb led system (singl e circuit with expiratory valve and pressure line). If your system does not have any acce ssories (external battery, supplemental oxygen), y ou can now switc h your device on , see “Switching on and shut ting down” on page 19 . 3.5 Connecting accessor ...

  • ResMed NOT014224-2 - page 22

    17 Connection procedures This F igure is a detailed view o f the connection of th e cable to the device . Figure 18: Detailed v iew of connection to the device. ! CAUTION T o remove the connection cable (see next Figure): Press on t he blac k retention pin on the cable connector . Still holding it down, pull the cable tow ards you . Figure 19: Remo ...

  • ResMed NOT014224-2 - page 23

    18 Connecting supplemental oxygen (optional) The instructions in this section apply only t o the connection of supplemental oxygen to your device. Ref er to the instructions given by your HME provider or installation te chnician for starti ng up the supplemental oxygen flow. ! CAUTION Before connecting the oxygen flow , always ensure that the oxyge ...

  • ResMed NOT014224-2 - page 24

    19 Switching on and shutting down 4 Switching on and shutting down 4.1 Standby When your device is co nnected to the mains power supp ly, it goes int o standby mode. The screen display shows: • The date • The t im e • The t ypes of po w er supply: mains po wer su pply and built-in bat ter y . Th e arro w points to the type of pow er supply cu ...

  • ResMed NOT014224-2 - page 25

    20 ...

  • ResMed NOT014224-2 - page 26

    21 Cleaning and Maintenanc e 5 Cleaning and Maintenance We recommend that you maintain your device and accessories regularly. ! CAUTION If you use the following accessories: • Mask • Humidifier • Antibacteria l filter • Wa t e r t r a p , follow the instructions provided in the manuals for eac h accessory , and the instructions of your phys ...

  • ResMed NOT014224-2 - page 27

    22 ! WARNING T o avoid an y risk of electric shoc k, never immer se the device or power cable in water . Always unp lug the device before cleaning and be sure that it is dry before plugging it bac k in. ! CAUTION Do not at tempt to open the device casing. R epair s and internal servicing should only be performed by an authorised service agent. Exte ...

  • ResMed NOT014224-2 - page 28

    23 T roubleshootin g 6 Troubleshooting Alarms will alert you to any problems with your device. The instructions in this section will help you to identify the cause of t he problem. If the fault persist s or cannot b e identified, do not try to ope n the device , and contact y our HME pr ovider . An alarm will activate an audible signa l. If you kno ...

  • ResMed NOT014224-2 - page 29

    24 Lo w pressure alarm (LP) This alarm also indicates a wrongly connected or disconnected circuit. Reconnect the circuit. High pressure alarm (HP) A component in your circuit is bloc ked. Clean, empty or replace the components of your circuit. Contact your HME if this alarm is activated too of te n. Alarm Cause So lu ti on P P ...

  • ResMed NOT014224-2 - page 30

    25 T echnical Sp ecifications 7 Technical Specifications CE-marked device: 7.1 Dimensions L: Length H: Height D: Depth 7.2 Weight VS Integra model (red) without battery option VS Ultra model (blue) or VS Integra (battery option) 01 9 7 H = 135 mm L = 285 mm D = 204 mm 3 k g 3.5 k g ...

  • ResMed NOT014224-2 - page 31

    26 7.3 Power supply Mains pow er 230/100 VAC; 50-6 0 Hz; 52 VA, 630 mA. Exter nal po we r supply 26 VDC; 3 A maximum. Built-in bat t ery (option f or VS Integr a) NiMh 24 V; 2.2-2.7 Ah Bat te ry lif e of built-in bat t ery (option f or VS Integr a) 2 – 4 hours, depending on set tings. Extra batt ery lif e with ext ernal bat tery (optional accesso ...

  • ResMed NOT014224-2 - page 32

    27 Appendix 8 Appendix Travelling with your ventilator For long journeys it is advisable to carry your device in its travel bag, with the following accessories: • The po wer cable • The circuit and its accessories • The mask • The ox ygen coupling (if you use the supple mental oxy gen opt ion). If you use an external batter y, place in its ...

  • ResMed NOT014224-2 - page 33

    28 ...

  • ResMed NOT014224-2 - page 34

    29 Index Index A accessories 8, 1 6 air outlet 5, 1 5 alarm silence b ut ton 1 0, 1 9 B bat ter y 1 2 bat ter y holder 9, 1 6 bat ter y lif e 26 built-in bat ter y 1 2, 19 C circuit 21 control panel 4, 1 0 D date 1 9 double circuit 2, 5, 8, 1 2 , 1 5 dust filter 1 1 E expiratory valve 1 3, 1 4 extern al bat ter y 9, 1 6 F fasten ing clip 6, 1 1 H h ...

  • ResMed NOT014224-2 - page 35

    Global leaders in sleep and respiratory medicine www .resmed.com HME provider references *N0T014224* ...

メーカー ResMed カテゴリー Ventilation Hood

ResMed NOT014224-2のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- NOT014224-2の取扱説明書
- ResMedの製品カード
- パンフレット
- またはResMed NOT014224-2の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ResMed NOT014224-2の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ResMed NOT014224-2の取り付け説明書、サービスマニュアル、簡易説明書、またはResMed NOT014224-2のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ResMed NOT014224-2の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ResMed NOT014224-2デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがResMed NOT014224-2を使用するのを助ける技術的文書のことです。説明書は通常、全てのResMed NOT014224-2ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ResMedの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ResMed NOT014224-2の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははResMed NOT014224-2の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ResMed NOT014224-2に関してこのドキュメントで見つけることができる全てのヒントの目次
3. ResMed NOT014224-2デバイスの基本機能を使うにあたってのヒント。 ResMed NOT014224-2のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ResMed NOT014224-2に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるResMed NOT014224-2のメーカー/サービスへの連絡先に関する情報。

ResMed NOT014224-2についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもResMed NOT014224-2の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがResMed NOT014224-2で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)