    1 Pub. 988-0154-442 EP-80R TH Electronic Thru-Hull Temp Sensor Installation and Configuration Instructions This document shows how to install an EP-80R TH thru-hull temp sen- sor and how to connect it to a NMEA 2000 ® network. It also provides instructions on how to configure your temp sensor with Lowrance digi- tal gauges (LMF-200 & LMF-400) ...

  • Lowrance electronic EP-80R TH - page 2

    2 Some sonar or GPS units may require a software upgrade to display NMEA 2000 data correctly. For free software upgrades or additional information on the LowranceNet NMEA 2000 ® network system, visit our web site, www.lowrance.com. The EP-80R TH consists of the temp sensor module, a red cable connec- tor and the smart module, which converts analog ...

  • Lowrance electronic EP-80R TH - page 3

    3 LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot extension cable, T connector and two 120-ohm terminators. Recommended Tools and supp lies Recommended tools for this job include: drill, 1/8" (3 mm) drill bit for pilot hole, 1-1/16 (27 mm) hole saw with a blade type appropriate for the com- position of your transom. Required su ...

  • Lowrance electronic EP-80R TH - page 4

    4 Afterwards, clean the area around th e hole with detergent or alcohol. This will establish a good surface for the adhesive. 5. Using a high quality, marine-g rade above- or below-waterline seal- ant/adhesive compound, apply a 1/8" (3 mm ) bead of sealant around the lip of the EP-80R TH housing. 6. Make sure the nut has been removed from the ...

  • Lowrance electronic EP-80R TH - page 5

    5 Cross section of transom showing EP-80R TH installed . Connecting to a NMEA 2000 Network A NMEA 2000 network is a communications link between two or more devices that transfer NMEA 2000 in formation. LowranceNET is the NMEA 2000 networking system develo ped by Lowrance Electronics. A NMEA 2000 network functions like the phone wiring in a house. I ...

  • Lowrance electronic EP-80R TH - page 6

    6 Network Backbone and Network Nodes A network bus backbone consists of network cabling, terminators and T connectors. Network nodes are made by fitting T-shaped connectors into the backbone (using the sockets on the sides) and attaching any network device to the bottom of the T. Staying with the previous phone wiring example, T connectors on the b ...

  • Lowrance electronic EP-80R TH - page 7

    7 All T connectors on your network pro bably will be connected to a device. If you want to add another node to a working network, add another T connector. T connectors may be purch ased from LEI (ordering informa- tion appears on the back page of this booklet). If you are adding a Lowrance or LEI NMEA 2000 sensor, it will come with a T connector. A ...

  • Lowrance electronic EP-80R TH - page 8

    8 Notes ...

  • Lowrance electronic EP-80R TH - page 9

    9 LMF-200: EP-80R TH Temp Configuration This section will show you how to use the LMF-200 Multi-function gauge to configure your EP- 80R TH Temperature Sensor. NOTE: You will notice the LMF-200 does not have an Exit key. Menus will time out after a preset amount of time (3, 5, 10 or 15 seconds). The default setting is 5 seconds. Re fer to your LMF- ...

  • Lowrance electronic EP-80R TH - page 10

    10 3. If you selected a configuration with more than one tank you will have to select the tank you want to set up and press MENU , which will open the Tank Size window. (If you choos e a single-tank configuration, you will not have to choose the tank. You will be directed straight to the Tank Size window covered in Step 4.) 4. Use the UP and DOWN k ...

  • Lowrance electronic EP-80R TH - page 11

    11 To unconfigure a temp sensor: 1. Press MENU , use the UP and DOWN k e y s t o s e l e c t S YSTEM S ETUP and press MENU . 2. Highlight B. D EVICES and press MENU , which will open the Bus Devices list. 3. Select a temp sensor from the Bus Devices list and press MENU . The Configuration Options menu will appear with two choices: Unconfig (Unconfi ...

  • Lowrance electronic EP-80R TH - page 12

    12 7. Select R ECONFIG and press MENU to open the Selecting Temp menu. Highlight W ATE R and press MENU . You will be directed to the Bus De- vices list. 8. Highlight U N C FG T EMP and press MENU . The following message will appear: Hit Menu to Cfg Temp Sns . 9. Press MENU to be taken to the Selecting Temp menu. Choose O UTSIDE and press MENU . Yo ...

  • Lowrance electronic EP-80R TH - page 13

    13 Customizing Pages The customizing pages feature allows you to choose what data will be displayed and how it will be displayed on select pages. You can custom- ize the Gauge, Single Digital and Dual Digital pages with temp sensor data. To customize Gauge pa ge: 1. After the Gauge page has been added to the page screen rotation, use the UP and DOW ...

  • Lowrance electronic EP-80R TH - page 14

    14 Notes ...

  • Lowrance electronic EP-80R TH - page 15

    15 LMF-400: EP-80R TH Temp Configuration This section will show you how to use the LMF-400 Multi-function gauge to configure your EP- 80R TH Temperature Sensor. LMF-400 Multi-function Digital gauge. Boat Setup If this is the first time you have turned on your LMF-400, you will have to complete Boat Setup before you will be able to configure your te ...

  • Lowrance electronic EP-80R TH - page 16

    16 5. After all tanks on your vesse l have been set up, press EXIT repeatedly to return to the main display. Boat Setup Reset If you want to access the Setup scr een (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configu- ration to default settings. To reset engine-tank config uration: 1. Press MENU , hi ...

  • Lowrance electronic EP-80R TH - page 17

    17 3. Choose the desired temp sensor and press ENTER . Select U NCONFIGURE from the temp configuration menu and press ENTER . The following message will appear: Press Menu to UnConfig Device Name . 4. Press ENTER to unconfigure the sensor and be directed to the Bus Devices list where the temp now will be listed as UnCfg Temp. Bus Devices highlighte ...

  • Lowrance electronic EP-80R TH - page 18

    18 configuration menu. Select R ECONFIGURE and press ENTER . That will di- rect you to the Temp Selection menu, which will have three options: Water, Outside and Inside. 6. Select O UTSIDE and press ENTER . You will be taken back to the Bus Devices list. The temp you just reco nfigured (formerly water temp) will now be displayed as Outside Temp. 7. ...

  • Lowrance electronic EP-80R TH - page 19

    19 To add a page to the dis play: 1. Press MENU , use the UP and DOWN k ey s t o s el ec t P AGE S and press EN- TER . A menu will pop up with four options: Add Page, Remove Page, Page Scrolling and Pop-Ups Setup. 2. Select A DD P AGE and press ENTER . 3. Highlight (Single Analog, Dual An alog, Quad Analog, Single Digital, Dual Digital or Quad Digi ...

  • Lowrance electronic EP-80R TH - page 20

    20 5. Highlight T EMPERATURE and press ENTER . The Select Temp menu will appear with three temp types: Wa ter Temp, Outside Temp and Inside Temp. 6. Select the desired temp type and press ENTER . You will be directed to the Position menu. Repeat steps 4 and 5 to customize the other posi- tion, or press EXIT twice to return to the main display. To c ...

  • Lowrance electronic EP-80R TH - page 21

    21 4. Select T EMPERATURE and press ENTER . The Select Temp menu will ap- pear with three temp types: Wate r Temp, Outside Temp and Inside Temp. 5. Select the desired temp type and press ENTER . You will be directed to the Position menu. Repeat steps 3 through 5 to customize the other po- sition, or press EXIT twice to return to the main display. T ...

  • Lowrance electronic EP-80R TH - page 22

    22 Notes ...

  • Lowrance electronic EP-80R TH - page 23

    23 Display Unit: EP-80R TH Temp Configuration All NMEA 2000 capable Lowrance sonar and sonar/GPS combo display units can be used to configure your EP-80R TH thru-hull temp sensor on a NMEA 2000 network. The LMS-525cDF is one of many Lowrance display units that may be used to configure an EP-80R TH thru-hull temp sensor. NMEA 2000 Menu/Networking Me ...

  • Lowrance electronic EP-80R TH - page 24

    24 Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup se- lected on Networking menu (right). EP-80R TH Temp Sensor Configuration The Temp Type function will be used when configuring your temp sen- sor through a display unit. You will se lect a configuration name for the temp from the Temp Type menu. Yo u can also change the Device Name f ...

  • Lowrance electronic EP-80R TH - page 25

    25 4. Press ENTER . Use the arrow keys to input the desired name for the temp sensor and press ENTER . Press EXIT repeatedly to return to the main display. To reset device name to default setting: 1. Press MENU twice, select NMEA 2000 or N ETWORKING and press ENTER . A menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms ...

  • Lowrance electronic EP-80R TH - page 26

    26 Unconfiguring a Temp Sensor You could unconfigure a temp sensor by changing its temp type to un- known or you can use the Restore Defaults command, which will reset the temp type and device name to default settings. To restore default se ttings : 1. Press MENU twice, select NMEA 2000 or N ETWORKING and press ENTER . A menu will appear with five ...

  • Lowrance electronic EP-80R TH - page 27

    27 Displaying EP-80R TH Temp Sensor Information The Overlay Data function will be used to show temp sensor data on your unit's main display. NOTE : Make sure your temp sensor has b een configured before attempting to display temperature data on your display unit. To add temp senso r as overlay data: 1. Press MENU , highlight O VERLAY D ATA and ...

  • Lowrance electronic EP-80R TH - page 28

    28 Notes ...

  • Lowrance electronic EP-80R TH - page 29

    29 Notes ...

  • Lowrance electronic EP-80R TH - page 30

    30 Notes ...

  • Lowrance electronic EP-80R TH - page 31

    31 LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY "We," "our," or "us" refers to LOWRAN CE ELECTRONICS, INC., the manufacturer of this product. "You" or "your" refers to the first person wh o purchases this p roduct as a consumer item for personal, family or household use. We warrant this product again ...

  • Lowrance electronic EP-80R TH - page 32

    32 How to Obtain Service… …in the USA: Contact the Factory Customer Se rvice Department. Call toll-free: For Lowrance: 800-324-1356. For Eagle: 800-324-1354 8 a.m. to 5 p.m. Central Standard Time, M-F Lowrance Electronics and Eagle Electronics ma y find it necessary to change or end their shipping policies, regulations and special offers at any ...

メーカー Lowrance electronic カテゴリー Thermostat

Lowrance electronic EP-80R THのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EP-80R THの取扱説明書
- Lowrance electronicの製品カード
- パンフレット
- またはLowrance electronic EP-80R THの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lowrance electronic EP-80R THの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lowrance electronic EP-80R THの取り付け説明書、サービスマニュアル、簡易説明書、またはLowrance electronic EP-80R THのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lowrance electronic EP-80R THの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lowrance electronic EP-80R THデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLowrance electronic EP-80R THを使用するのを助ける技術的文書のことです。説明書は通常、全てのLowrance electronic EP-80R THユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lowrance electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lowrance electronic EP-80R THの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLowrance electronic EP-80R THの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lowrance electronic EP-80R THに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lowrance electronic EP-80R THデバイスの基本機能を使うにあたってのヒント。 Lowrance electronic EP-80R THのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lowrance electronic EP-80R THに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLowrance electronic EP-80R THのメーカー/サービスへの連絡先に関する情報。