Listen Technologies RP 6004の取扱説明書

14ページ 0.52 mb
ダウンロード

ページに移動 of 14

Summary
  • Listen Technologies RP 6004 - page 1

    DCS 6000 User Manual Danish Interpretation Systems DI S Digital Conference System RP 6004 Repeater ...

  • Listen Technologies RP 6004 - page 2

    Danish Interpretation Systems User Manual Copyright © 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permiss ion in writing from the pub lisher. ...

  • Listen Technologies RP 6004 - page 3

    Danish Interpretation Systems User Manual Copyright © 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permiss ion in writing from the pub lisher. List of Contents List of Contents ................................................. 3 Document version ................... ...

  • Listen Technologies RP 6004 - page 4

    Danish Interpretation Systems User Manual Manual 01 18 04466 4 Important Compliancy The equipment has been tested and found to co m ply with the limits of the following standards for digital devices: • EN55103 - 1 (Emission) • EN55103 - 2 (Immunity) • FCC rules part 15, class A (Emission) This de vice complies with part 15 of the FCC rules. O ...

  • Listen Technologies RP 6004 - page 5

    Danish Interpretation Systems User Manual Manual 01 18 04466 5 Description of the DCS 6000 system Features The DCS 6000 system has the following main features: • Fully digital • Excellent sound quality • “State of the Art” fully digital integrated interpretation, discussion and vo t ing system offering interpretation, language distr i but ...

  • Listen Technologies RP 6004 - page 6

    Danish Interpretation Systems User Manual Manual 01 18 04466 6 System components The CU 6010 Central Unit supports all available units in the DCS 6000 series: Central equipment CU 6010 Central Unit EX 6010 Extension Power Unit PS 6000 Power Supply RP 6004 Repeater for four chains AO 6008 Audio Output box JB 6002 Junction Box with 2 outputs JB 6004 ...

  • Listen Technologies RP 6004 - page 7

    Danish Interpretation Systems User Manual Manual 01 18 04466 7 Operating instructions RP 6004 Repeater General description The RP 6004 Repe ater provides repeater and splitter functionality for the DCS 6000 system. One CU 6010 Central Unit is needed in each DCS 6000 system, however for expansion of the system the RP 6004 Repeater is suitable. The R ...

  • Listen Technologies RP 6004 - page 8

    Danish Interpretation Systems User Manual Manual 01 18 04466 8 q Power LED Those LED light up when Power is av ailable on the connector next to the LED q Incoming data LED Those LED flashes, when the unit receives incoming data from connected units on the connector next to the LED. System design There are no settings to be done on the RP 6004 Repea ...

  • Listen Technologies RP 6004 - page 9

    Danish Interpretation Systems User Manual Manual 01 18 04466 9 ‘Loop through’ connector When connecting a number of RP 6004 Repeaters to the CU 6010 an almost unlimited number of RP 6004 can be connected by using the ‘Loop through’ connector. The practical limitation is the maxim um cable length in one chain, which is 200 m and supply of po ...

  • Listen Technologies RP 6004 - page 10

    Danish Interpretation Systems User Manual Manual 01 18 04466 10 System Setup General guidelines Connect the RP 6004 to the various units using Cat 5 FTP or STP cables. Please observe the following guide lines: • Maximum cable length in one chain is 200 m without repeater. This includes interconnection cables between the units. The max. usable cab ...

  • Listen Technologies RP 6004 - page 11

    Danish Interpretation Systems User Manual Manual 01 18 04466 11 Typical schematics The following schematics are showing various configurations : Large sized conference microphone system ...

  • Listen Technologies RP 6004 - page 12

    Danish Interpretation Systems User Manual Manual 01 18 04466 12 Various configurations with RP 6004 Repeater and PS 6000 Power Supply ...

  • Listen Technologies RP 6004 - page 13

    Danish Interpretation Systems User Manual Manual 01 18 04466 13 Technical appendix Cabling CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors . It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened. EIA 568 - B wiring shall be used. ...

  • Listen Technologies RP 6004 - page 14

    Danish Interpretation Systems User Manual Manual 01 18 04466 14 ...

メーカー Listen Technologies カテゴリー Network Card

Listen Technologies RP 6004のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RP 6004の取扱説明書
- Listen Technologiesの製品カード
- パンフレット
- またはListen Technologies RP 6004の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Listen Technologies RP 6004の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Listen Technologies RP 6004の取り付け説明書、サービスマニュアル、簡易説明書、またはListen Technologies RP 6004のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Listen Technologies RP 6004の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Listen Technologies RP 6004デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがListen Technologies RP 6004を使用するのを助ける技術的文書のことです。説明書は通常、全てのListen Technologies RP 6004ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Listen Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Listen Technologies RP 6004の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははListen Technologies RP 6004の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Listen Technologies RP 6004に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Listen Technologies RP 6004デバイスの基本機能を使うにあたってのヒント。 Listen Technologies RP 6004のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Listen Technologies RP 6004に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるListen Technologies RP 6004のメーカー/サービスへの連絡先に関する情報。

Listen Technologies RP 6004についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもListen Technologies RP 6004の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがListen Technologies RP 6004で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)