  • CDA EVPC9 - page 1

    EVPC9 Ex tractor Manual for Installation, Use and Maintenance Customer Care Department • The Group Ltd. • Harb y Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www.cda.eu Passionate about style ...

  • CDA EVPC9 - page 2

    Impor tant The manufacturer cannot be held responsible for injuries or losses caused by inc orrect use or installation of this product. Please note that the manufacturer reserves the right to invalidat e the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial en vironment. This app ...

  • CDA EVPC9 - page 3

    2 Using your Extractor For best performance, y ou should switch on the extractor 15 minutes before starting to cook and leave it to run f or approximately 15 minut es after the end of cooking. Control P anel A - Light key B - Decrease speed key C - Display D - Increase speed key E - Timer key T o switch the ex tractor light on and o • T ouch k ...

  • CDA EVPC9 - page 4

    3 Care and Maintenanc e IMPORT ANT : DO NO T PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICIT Y SUPPL Y . Cleaning Y ou should use a nonabrasive cleaner . Any abrasive cleaner (including Cif ) will scratch the surface and could erase the control panel markings. Y ou can clean your extractor eectively by ...

  • CDA EVPC9 - page 5

    4 Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIA TEL Y AFTER USE AS THE BULB WILL BE HOT . ALLOW IT TO C OOL BEFORE REMOVING IT . Unscrew the light bulb cov er , please see gure 4. Unscrew the light bulb and replace with a 12V 20W halogen light bulb. F inally , replace the light bulb cov er . Do not touch bulbs or adjacent areas during ...

  • CDA EVPC9 - page 6

    5 DOUBLE POLE SWITCHED FUSED SPUR OUTLET USE A 3 AMP FUSE Mains Electr icity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPL Y BY A C OMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We r ecommend that the appliance is connected by a qualied electrician, who is a member o ...

  • CDA EVPC9 - page 7

    Electrical I nformation Mains electrical voltage: 230 – 240V ac, 50Hz T otal rated power consumption: 310W T roubleshooting If your extractor is not working: 1. Check that the mains supply has not been switched o . 2. Check that the fuse in the spur has not blown. 6 ...

  • CDA EVPC9 - page 8

    Mounting your Extractor When the extractor is to be installed above hob , the minimum distance between the hob and extractor must exceed 650mm. If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater than 650mm, then that is the distanc e that should be observed; this is a legal ...

  • CDA EVPC9 - page 9

    8 Installation It is impor tant that wall plugs and screw s are selected that are suitable for the wall type you will be xing the extractor to. CD A will not be liable for any issue arising from the use of unsuitable plugs and screws. The extractor is mounted to the wall using brackets and support rails. T o install the product onto the wall, pr ...

  • CDA EVPC9 - page 10

    9 Fig . 9 Installation 5. Using the chimney top support bracket as a guide, mark the hole positions on the wall and ceiling at the required positions (Fig 9 5A & B), drill and t the bracket to the wall and ceiling, using appropriat e xings (D & E). 6. If venting the extractor outside, connect the vent adaptor to the ducting pipe as sh ...

  • CDA EVPC9 - page 11

    10 Attribute Symbol Value Units Model Identification evpc9 Annual Energy Consumption AEC Hood 119.6 kWh Time increase factor f 1.4 Fluid Dynamic Efficiency FDE Hood 16.1 (D) Energy Efficiency Index EEI Hood 92.9 (D) Measured airflow at Best Efficiency Point Q BEP 347.6 m 3 /h Measured Pressure at Best Efficiency Point P BEP 244.0 Pa Maximum airflow ...

  • CDA EVPC9 - page 12

    Customer Care Department • The Group Ltd. • Harb y Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www.cda.eu Passionate about style T o contact our Customer Car e Depar tment, or for Service, please contact us on the details below . ...

メーカー CDA カテゴリー Exhaust hood

CDA EVPC9のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EVPC9の取扱説明書
- CDAの製品カード
- パンフレット
- またはCDA EVPC9の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、CDA EVPC9の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、CDA EVPC9の取り付け説明書、サービスマニュアル、簡易説明書、またはCDA EVPC9のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、CDA EVPC9の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

CDA EVPC9デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCDA EVPC9を使用するのを助ける技術的文書のことです。説明書は通常、全てのCDA EVPC9ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

CDAの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. CDA EVPC9の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCDA EVPC9の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。CDA EVPC9に関してこのドキュメントで見つけることができる全てのヒントの目次
3. CDA EVPC9デバイスの基本機能を使うにあたってのヒント。 CDA EVPC9のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。CDA EVPC9に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCDA EVPC9のメーカー/サービスへの連絡先に関する情報。

CDA EVPC9についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCDA EVPC9の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCDA EVPC9で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)