Black Box RS-422の取扱説明書

17ページ 0.16 mb
ダウンロード

ページに移動 of 17

Summary
  • Black Box RS-422 - page 1

    Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com CUSTOMER SUPPORT INFORMATION FEBRU AR ...

  • Black Box RS-422 - page 2

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 1 FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio-frequency energy , and if not installed and used properly , that is, in strict accordance with the manufacturer’ s instructions, may cause inter ference t ...

  • Black Box RS-422 - page 3

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 2 INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement) 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas ...

  • Black Box RS-422 - page 4

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 3 TRADEMARKS USED IN THIS MANUAL Any trademarks mentioned in this manual are acknowledged to be the pr operty of the trademark owners. ...

  • Black Box RS-422 - page 5

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 4 Contents Chapter Page 1.Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Black Box RS-422 - page 6

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 5 1. Specifications Speed — 64,000 bps, max. Connectors — RS-232 port: DB25 female; RS-422 port: DB37 female Indicators — 7 LEDs show status of RS-232 and RS-422 signals and indicate power ON. RS-232 Port: DSR, CTS, DA T A; RS-422 Port: DSR, CTS, DA T A Controls — RS-232 port: DTE/DCE DIP shunts; RS-4 ...

  • Black Box RS-422 - page 7

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 6 2. Introduction The RS-232 ↔ RS-422 Inter face Converter provides bi-directional synchronous or asynchronous conversion of all commonly used RS-232 and RS-422 signals. The unit is designed to operate with one port configured as Data T erminal Equipment (DTE) and the other port as Data Communications Equip ...

  • Black Box RS-422 - page 8

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 7 1. The Converter does not require special handshaking signals in order to operate. 2. The Converter should always be configured the opposite of the equipment it’ s connected to if straight-through cabling is used. For example, if you are connecting a modem (a DCE device) to the Converter , configure the C ...

  • Black Box RS-422 - page 9

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 8 3. Installation T o connect the Converter to your devices, follow these steps: 1. Attach the cable from the RS-422 device to the 37-pin female receptacle on the rear panel of the Converter . 2. Attach the cable from the RS-232 device to the 25-pin female receptacle on the rear panel of the Converter . 3. Pl ...

  • Black Box RS-422 - page 10

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 9 Figure 3-1. Board Layout Showing Component Locations. (Dashed Lines show DTE/DCE DIP Shunt Locations.) AC POWER CONNECTOR RS-422 CONNECTOR RS-232 CONNECTOR DIP SHUNTS DIP SHUNTS DSR CTS DA T A RS-422 INDICA TORS POWER DSR CTS DA T A RS-232 INDICA TORS XW1A XW2A XW3A XW4A XW4B XW5A XW5B XW1B XW2B XW3B CR8 CR ...

  • Black Box RS-422 - page 11

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 10 Figure 3-2. Sample DIP-Shunt Setting. Figure 3-2 shows the DIP-shunt settings used for an application like the one illustrated in Figure 3-3a. NOTE The filled-in rectangles in Figure 3-2 indicate the jumpers that contain a DIP-shunt. CAUTION Never set both ports the same: the cloc ks will not operate corre ...

  • Black Box RS-422 - page 12

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 11 Figures 3-3a and 3-3b show some typical synchronous applications. Figure 3-3. Synchr onous Applications. Applications involving asynchronous devices are also possible. Figure 3-4 illustrates a popular asynchronous setup, while Figure 3-5 shows the cabling involved. Figure 3-4. RS-422 Asynchr onous Applicat ...

  • Black Box RS-422 - page 13

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 12 T HE R ECEIVER T ERMINA TION S WITCH This switch is marked S1 on the printed circuit-board diagram in Figures 3-1 and 3-2. This switch ser ves to terminate the receiver with pull-up and pull-down resistors in order to designate the receiver state and enable the Converter’ s anti-streaming function. Setti ...

  • Black Box RS-422 - page 14

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 13 Figure 3-5. Signal Flow Diagram A. RS-232 (Port is DTE) RS-422 (Port is DCE) 12 Terminal Ready A (-) 30 Terminal Ready B (+) DTR 20 CR8 (RS-422 DSR LED) 11 29 Data Mode A (-) Data Mode B (+) DSR 6 CR9 (RS-232 DSR LED) CTS 5 9 27 Clear to Send A (-) Clear to Send B (+) CR4 (RS-232 CTS LED) RTS 4 7 25 Reques ...

  • Black Box RS-422 - page 15

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 14 Figure 3-6. Signal Flow Diagram B. RS-232 (Port is DCE) RS-422 (Port is DTE) 12 Terminal Ready A (-) 30 Terminal Ready B (+) DTR 20 CR8 (RS-422 DSR LED) 11 29 Data Mode A (-) Data Mode B (+) DSR 6 CR9 (RS-232 DSR LED) CTS 5 9 27 Clear to Send A (-) Clear to Send B (+) CR4 (RS-232 CTS LED) RTS 4 7 25 Reques ...

  • Black Box RS-422 - page 16

    RS-232 ↔ RS-422 INTERF ACE CONVER TER 15 4. Ground Strap and Inter face Pinouts Signal grounds (Pins 19, 20, and 37 on the RS-422 inter face and Pin 7 on the RS-232 inter face) are connected together , but not connected to chassis ground (Pin 1). However , for applications requiring all grounds to be at a common reference point, these pins can be ...

  • Black Box RS-422 - page 17

    1000 P ark Drive • Lawrence, P A 15055-1018 • 724-746-5500 • F ax 724-746-0746 © Copyright 1998. Black Box Corporation. All rights reserv ed. ...

メーカー Black Box カテゴリー TV Converter Box

Black Box RS-422のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RS-422の取扱説明書
- Black Boxの製品カード
- パンフレット
- またはBlack Box RS-422の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Black Box RS-422の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Black Box RS-422の取り付け説明書、サービスマニュアル、簡易説明書、またはBlack Box RS-422のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Black Box RS-422の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Black Box RS-422デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBlack Box RS-422を使用するのを助ける技術的文書のことです。説明書は通常、全てのBlack Box RS-422ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Black Boxの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Black Box RS-422の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBlack Box RS-422の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Black Box RS-422に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Black Box RS-422デバイスの基本機能を使うにあたってのヒント。 Black Box RS-422のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Black Box RS-422に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBlack Box RS-422のメーカー/サービスへの連絡先に関する情報。

Black Box RS-422についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBlack Box RS-422の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBlack Box RS-422で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください