  • Omega Vehicle Security PTC900 - page 1

    P P T T C C 9 9 0 0 0 0 / / P P T T C C 9 9 0 0 1 1 Panel -M M ount P P rogram mable Timer a a nd R R eal -T T ime C C lock omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at LP0678A ...

  • Omega Vehicle Security PTC900 - page 2

    OMEGAnet ® Online Ser vice omega.com Inter net e-mail info@omega.com Ser vicing North America: U.S.A.: One Omega Drive, P .O . Bo x 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F A X: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F A X: (514) 856-6886 e-mail: info ...

  • Omega Vehicle Security PTC900 - page 3

    3 z 6-DIGIT 0.56" RED SUNLIGHT READABLE DISPLA Y z 4 SEP ARA TE DISPLA YS (Timer , Counter, Real-T ime Clock, and Date) z CYCLE COUNTING CAP ABILITY z PROGRAMMABLE FUNCTION KEYS/USER INPUTS z FOUR SETPOINT ALARM OUTPUTS (W/Plug-in card) z COMMUNICA TIONS AND BUS CAP ABILITIES (W/Plug-in card) z PC SOFTWARE A V AILABLE FOR METER CONFIGURA TION ...

  • Omega Vehicle Security PTC900 - page 4

    4 General Meter S pecifications . . . . . . . . . . . . . 4 Optional Plug-In Cards and Accessories . . . . 5 Installing the Meter . . . . . . . . . . . . . . . . . . . . 6 Setting the Jumpers . . . . . . . . . . . . . . . . . . . 6 Installing Plug-In Cards . . . . . . . . . . . . . . . . . 7 Wiring the Meter . . . . . . . . . . . . . . . . . . . . ...

  • Omega Vehicle Security PTC900 - page 5

    5 O PTIONAL P LUG - IN C ARDS AND A CCESSORIES W ARNING: Disconnect all power to the unit before installing Plug-in cards. Adding Option Cards The PTC900/PTC/901 series meters can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section below . Only one card from each function ...

  • Omega Vehicle Security PTC900 - page 6

    6 Installation The meter meets NEMA 4X/IP65 requirements for indoor use when properly installed. The meter is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel latch from the meter . Slide the panel gasket over the rear of the meter to the back of the bezel. The meter should be install ...

  • Omega Vehicle Security PTC900 - page 7

    7 3.0 I NSTALLING P LUG -I N C ARDS The Plug-in cards are separately purchased optional cards that perform specific functions. These cards plug into the main circuit board of the meter . The Plug-in cards have many unique functions when used with the meters. CAUTION : The Plug-in card and main circuit board contain static sensitive components. Befo ...

  • Omega Vehicle Security PTC900 - page 8

    8 Before connecting the wires, the T imer Input logic jumper should be verified for proper position. 4.2 TIMER INPUT WIRING CAUTION : T imer Input common is NOT isolated from User Input common. In or der to pr eserve the safety of the meter application, the timer input common must be suitably isolated fr om hazar dous live earth r efer enced voltag ...

  • Omega Vehicle Security PTC900 - page 9

    9 4.4 SETPOINT (ALARMS) WIRING SETPOINT PLUG-IN CARD TERMINALS SINKING OUTPUT LOGIC CARD SOURCING OUTPUT LOGIC CARD 4.5 SERIAL COMMUNICA TION WIRING RS232 Communications RS232 is intended to allow two devices to communicate over distances up to 50 feet. Data T erminal Equipment (DTE) transmits data on the T ransmitted Data (TXD) line and receives d ...

  • Omega Vehicle Security PTC900 - page 10

    10 T ime synchronization between multiple PTC901 meters can be accomplished through a hardware interface on the Real-T ime Clock option card. This RS485 type interface allows connection of up to 32 PTC901 meters in a two-wire multidrop network, at distances up to 4000 ft. In a synchronization network, one PTC901 meter is programmed as the Host, whi ...

  • Omega Vehicle Security PTC900 - page 11

    11 PROGRAMMING MODE ENTR Y (P AR KEY) The Programming Mode is entered by pressing the PA R key . If this mode is not accessible, then meter programming is locked by either a security code or a hardware lock. (See Modules 2 and 3 for programming lock-out details.) MODULE ENTR Y (ARROW & P AR KEYS) Upon entering the Programming Mode, the display ...

  • Omega Vehicle Security PTC900 - page 12

    12 This parameter determines how the T imer Input Signals affect the “Run/Stop” status of the T imer . The timing diagrams below reflect a Sinking input setup (active low). A Sourcing input setup (active high) is available through plug jumper selection (see Section 2.0). In this case, the logic levels of the timing diagrams would be inverted. T ...

  • Omega Vehicle Security PTC900 - page 13

    13 ª «   ª «   NO FUNCTION W ith this selection, NO function is performed. This is the factory setting for all user inputs and function keys except the Reset ( RST ) Key . PROGRAMMING MODE LOCK-OUT Programming Mode is locked-out, as long as activated (maintained action). In Module 3, certain parameters can be ...

  • Omega Vehicle Security PTC900 - page 14

    14 ª «   ª «   DISPLA Y HOLD and RESET (Edge T riggered Reset) When activated, the meter “freezes” the display values entered as  in the sublist, before performing an internal Momentary Reset on the selected displays. This function does not apply to the R TC T ime or Date ...

  • Omega Vehicle Security PTC900 - page 15

    15 When active (maintained action), the meter “holds” (maintains) the present output state for all Setpoints entered as  in the sublist. Does not apply to Output Set and Reset User Inputs. Program only one user input for this function. Note : The r emaining parameters only appear when a Setpoint Car d is installed in the meter . ª « ...

  • Omega Vehicle Security PTC900 - page 16

    16  6.3 MODULE 3 - D ISPLAY AND P ROGRAM L OCK - OUT P ARAMETERS (  ) Module 3 is the programming module for setting the Display Lock-out Parameters and the “Quick Programming Mode” V alue Access Parameters. In the Quick Programming mode, after the PROGRAM LOCKOUT P ARAMETERS and before the Security Code (  ) ...

  • Omega Vehicle Security PTC900 - page 17

    17 6.4 MODULE 4 - C YCLE C OUNTER P ARAMETERS (  ) P ARAMETER MENU Module 4 is the programming module for the Cycle Counter Parameters. In the Display Mode, the CNT annunciator indicates the Cycle Counter display is currently being shown. An EXCHANGE P ARAMETER LISTS feature, which includes the Cycle Counter Start and S top V alues, ...

  • Omega Vehicle Security PTC900 - page 18

    18 Timing Diagrams for Predefined Timer Operating Modes NOTE : Input A is shown as a Sourcing input (active high). If a Sinking input (active low) is used, the logic levels for Input A would be inverted. Input A Output 1 T1  T2 T T1 Input A Output 1  T T Input A Output 1 T  T Input A Output 1 T  ...

  • Omega Vehicle Security PTC900 - page 19

    19 ª «   SETPOINT ACTION This parameter determines the mode for output deactivation as shown below . Output activation is controlled by the SETPOINT ON parameter setting. The  and  selections are not available when Setpoint is assigned to  .   ...

  • Omega Vehicle Security PTC900 - page 20

    20 DISPLA Y DESCRIPTION F ACTOR Y  Sunday   Monday       Saturday Friday Thursday Wednesday T uesday      TIME-OUT V ALUE  to  ª «   ª ...

  • Omega Vehicle Security PTC900 - page 21

    21 6.7 MODULE 7 - S ERIAL C OMMUNICATIONS P ARAMETERS (  ) P ARAMETER MENU This module can only be accessed if a Serial Communications Card is installed. * Only appears if the Real-Time Clock Card is installed. Module 7 is the programming module for the Serial Communications Parameters. These parameters are used to match the serial s ...

  • Omega Vehicle Security PTC900 - page 22

    22 SENDING SERIAL COMMANDS AND DA T A When sending commands to the meter , a string containing at least one command character must be constructed. A command string consists of a command character , a value identifier , numerical data (if writing data to the meter) followed by the command terminator character * or $. Command Chart Command String Con ...

  • Omega Vehicle Security PTC900 - page 23

    23 Abbreviated T ransmission (  =  ) ✰ These characters only appear in the last line of a block print. The abbreviated response suppresses the address and register mnemonics, leaving only the numeric part of the response. Note : T ransmissions are formatted to match the way the parameter is displayed. This includes setpoints. ...

  • Omega Vehicle Security PTC900 - page 24

    24 Module 8 is the programming module for the Real-Time Clock (R TC) Date and T ime Parameters. In the Display Mode, the DA T annunciator indicates the R TC Date is currently being shown. The R TC T ime display is shown with no annunciator . This programming module can only be accessed if a Real-T ime Clock card is installed. COMMUNICA TION FORMA T ...

  • Omega Vehicle Security PTC900 - page 25

    25 TIME DISPLA Y FORMA T ª «   DA TE DISPLA Y FORMA T AUTO CHANGE FOR DA YLIGHT SA VINGS TIME Select the format in which the Real-T ime Clock T ime will be displayed. The format selections depict the range for the R TC T ime display , and DO NOT represent the curr ent R TC Time. When the meter is operating in the Dis ...

  • Omega Vehicle Security PTC900 - page 26

    26 P ARAMETER MENU RESTORE F ACTOR Y DEF AUL TS Use the RST and/or arrow keys to display   and press PA R . The meter will display  and then returns to   . Press DSP key to return to the Display Mode. This will overwrite all programmed user settings with the Factory Default Settings shown in ...

  • Omega Vehicle Security PTC900 - page 27

    27 5-OPEr Timer Operating Modes DISPLA Y PARAMETER USER SETTING F ACTOR Y SETTING USEr-1 USER INPUT 1 NO USEr-2 USER INPUT 2 NO USEr-3 USER INPUT 3 NO F1 FUNCTION KEY 1 NO F2 FUNCTION KEY 2 NO rSt RESET KEY drSt-E SEC-F1 NO SEC-F2 SECONDARY FUNCTION KEY F2 NO 1-INP Timer Input Parameters 2-FNC User Input and Function Key Parameters 3-LOC Display an ...

  • Omega Vehicle Security PTC900 - page 28

    28 7-SrL Serial Communication Parameters DISPLA Y P ARAMETER F ACTOR Y SETTING USER SETTING bAUd BAUD RA TE 9600 dAtA DA T A BITS 7 PAr P ARITY BIT Odd Addr METER UNIT ADDRESS 00 Abbr ABBREVIA TED PRINTING NO   REAL-TIME CLOCK PRINT FORMA T YES OPt PRINT OPTIONS t-dSP TIMER DISPLA Y YES C-dSP CYCLE COUNTER DISPLA Y NO rtC-d RTC DA TE ...

  • Omega Vehicle Security PTC900 - page 29

    29                  T imer Range F1/F2 Keys T imer Input Operation T imer Input Filtering T iming Direction T imer S tart V alue T imer S top V alue Flash T imer Annunciator T ime ...

  • Omega Vehicle Security PTC900 - page 30

    30 P ART N UMBER I NFORMATION ACCESSORIES PTC9-RTC00 DP6-CDC4C Real-T ime Clock card Real-T ime Clock Extended MODBUS communications output card with dual RJ1 1 connectors DP6-CDC40 MODBUS communications output card with terminal block DP6-CDC2C Extended RS232 serial communications output card with 9-pin D connector DP6-CDC20 RS232 serial communica ...

  • Omega Vehicle Security PTC900 - page 31

    W ARRANTY/DISCLAIMER OMEGA ENGINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA ’s WARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s customers ...

  • Omega Vehicle Security PTC900 - page 32

    Where Do I F ind Everything I Need for P rocess Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERA TURE ] Thermocouple, RTD & Thermistor Probes, Connectors, P anels & Assemblies ] W ire: Thermocouple, R TD & Thermistor ] Calibrators & Ice P oint References ] Recorders, Controllers & Process Monitors ] I ...

メーカー Omega Vehicle Security カテゴリー Clock

Omega Vehicle Security PTC900のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PTC900の取扱説明書
- Omega Vehicle Securityの製品カード
- パンフレット
- またはOmega Vehicle Security PTC900の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Vehicle Security PTC900の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Vehicle Security PTC900の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Vehicle Security PTC900のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Vehicle Security PTC900の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Omega Vehicle Security PTC900デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Vehicle Security PTC900を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Vehicle Security PTC900ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Vehicle Securityの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Vehicle Security PTC900の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Vehicle Security PTC900の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Vehicle Security PTC900に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Vehicle Security PTC900デバイスの基本機能を使うにあたってのヒント。 Omega Vehicle Security PTC900のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Vehicle Security PTC900に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Vehicle Security PTC900のメーカー/サービスへの連絡先に関する情報。

Omega Vehicle Security PTC900についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Vehicle Security PTC900の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Vehicle Security PTC900で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)