    PN 644226 July, 1997 Rev.1, 3/99 © 1997,1999 Fluke Corporation, Al l rights reserved. Printed in U .S.A. All p r oduct names are trademarks of their respective companies. 1 ® 16 Multimeter with Temperature Calibration Information W Warning To avoid electrical shock, remove test leads and any input signals from the Meter before opening the case. C ...

  • Fluke Fluke 16 - page 2

    16 Multimeter with Temperature 2 Accuracy specifications are given as follows: ±([% of reading] + [number of least significant digits]). Table 1. Specifications (cont) Function Range Resolution Accuracy f (50 to 400 Hz) 4000 mV 1 4.000 V 40.00 V 300.0 V 400.0 V 600.0 V 1 mV 0.001 V 0.01 V 0.1 V 0.1 V 1 V ±(1.9%+3) ±(1.9%+3) ±(1.9%+3) NA ±(1.9% ...

  • Fluke Fluke 16 - page 3

    Specifications 3 Table 1. Specifications (cont) Function Overload Protection 1 Input Impedance (Nominal) Common Mode Rejection Ratio (1 k Ω Unbalanced) 2 Normal Mode Rejection 2 f 600 V dc >5 M Ω <100 pF 2 Automatic Selection and LoZ = >2 k Ω <200 pF (ac coupled) 3 >60 dB at dc 50 Hz or 60 Hz E 600 V dc >10 M Ω <100 pF ...

  • Fluke Fluke 16 - page 4

    16 Multimeter with Temperature 4 Disassembly and Reassembly Referring to Figure 1, disassemble the Meter as follows. A Phillips-head screwdriver and small flat-blade screwdriver are required. 1. Remove the test leads and set the rotary knob to OFF. 2. Remove the Phillips-head screws from the case bottom. 3. Separate the case top from the case botto ...

  • Fluke Fluke 16 - page 5

    Recommended Test Equipment 5 Case, Top Decal Switch Assembly Actuator, Switch Main PCA Shield, Bottom Foot LCD Conn. Elastomeric Conn. Elastomeric LCD to PCA Support, Switch Assembly Battery Shock Absorber Case, Bottom Screw, THD Form, PH.P.STL, 5-14 x .750 ig3f.eps Figure 1. Model 16 Disassembled Unit ...

  • Fluke Fluke 16 - page 6

    16 Multimeter with Temperature 6 1 2 3 Snap Snap Snaps ig2f.eps Figure 2. Removing and Reinserting the Printed Circuit Assembly ...

  • Fluke Fluke 16 - page 7

    Performance Test 7 Performance Test W Warning To avoid electric shock, do not execute the performance tests procedures unless the Meter is fully assembled. To ensure that the Meter is working properly and performs to specifications, use the following procedures. If the Meter fails this test, it needs calibration adjustment or repair. Multimeter Not ...

  • Fluke Fluke 16 - page 8

    16 Multimeter with Temperature 8 Table 3. Performance Tests Test No. Meter Range Input To Meter Switch Position Display Minimum Display Maximum 1 2 3 4 5 6 7 8 9 1 10 4.000 V ac 4.000 V ac, MIN MAX 4.000 V ac 4.000 V ac 4.000 V ac 4.000 V ac 40.00 V ac 40.00 V ac 400.0 V ac 600 V ac 0 V 0 V 10 mV, 50 Hz 10 mV, 400 Hz 3.5 V, 50 Hz 3.5 V, 400 Hz 35 V ...

  • Fluke Fluke 16 - page 9

    Calibration Adjustments 9 + + 5700A Ice Bath AK-80 Banana Plug Temperature Yellow Red Copper 0 ig6f.eps Figure 3. Performance Test for Temperature + _ 9V BATTERY + Clip to Base Contacts Adjust R4 for 3.997-4.003V DC Input Receptacles + ig1f.eps Figure 4. Calibration Adjustment for DC Voltage ...

  • Fluke Fluke 16 - page 10

    16 Multimeter with Temperature 10 Temperature Note Adjust DC voltage (R4) before adjusting temperature (R38). The following describes three temperature calibration procedures: • Calibrating at room temperature. Use this procedure if it is not necessary to optimize the Meter’s performance. • Calibrating in an ice bath. Use this procedure to op ...

  • Fluke Fluke 16 - page 11

    Replacement Parts 11 ! CAL ENABLE 10A 100 mA 1000V 750V MAX ALL INPUTS 1kV MAX 500mA F 250V POWER AUTO 2ND MN MX RATE dB REL LOCAL THRESH ADDR BAUD HOLD LO HI COMP A A V FREQ DUAL DISPLAY MULTIMETER 45 V REF# REF V COM FUSED 80T-150U + _ 9V BATTERY + + R38 Clip to Base Contacts V m ig4f.eps Figure 5. Calibration Adjustment for Temperature Using the ...

  • Fluke Fluke 16 - page 12

    16 Multimeter with Temperature 12 ...

メーカー Fluke カテゴリー Universal Remote

Fluke Fluke 16のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 16の取扱説明書
- Flukeの製品カード
- パンフレット
- またはFluke Fluke 16の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Fluke Fluke 16の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Fluke Fluke 16の取り付け説明書、サービスマニュアル、簡易説明書、またはFluke Fluke 16のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Fluke Fluke 16の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Fluke Fluke 16デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFluke Fluke 16を使用するのを助ける技術的文書のことです。説明書は通常、全てのFluke Fluke 16ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Flukeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Fluke Fluke 16の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFluke Fluke 16の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Fluke Fluke 16に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Fluke Fluke 16デバイスの基本機能を使うにあたってのヒント。 Fluke Fluke 16のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Fluke Fluke 16に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFluke Fluke 16のメーカー/サービスへの連絡先に関する情報。

Fluke Fluke 16についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFluke Fluke 16の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFluke Fluke 16で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)