Vermont Casting VCPV18TP - 18の取扱説明書

16ページ 0.35 mb
ダウンロード

ページに移動 of 16

Summary
  • Vermont Casting VCPV18TP - 18 - page 1

    1 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater VERMONT C astings Models: VCBV30TN, VCBV30TP - 30,000 Btu/Hr Thermostat VCBV20TN, VCBV20TP - 20,000 Btu/Hr Thermostat VCBV10TN, VCBV10TP - 10,000 Btu/Hr Thermostat Blue Flame Heaters Unvented Gas-Fired Room Heater Please read this manual before installing and using appliance. W ARNING: If the ...

  • Vermont Casting VCPV18TP - 18 - page 2

    2 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater SAFETY : Accidents are always tragic, especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices we hope you will follow for safe use of your gas fired room heater . IMPORT ANT : Read this user’s manual carefully and com ...

  • Vermont Casting VCPV18TP - 18 - page 3

    3 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater VCBVTN, VCBVTP , VCPVTN and VCPVTP Specifications NOTES: For altitudes above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level. DO NOT USE THIS HEA TER A T AN ELEV A TION ABOVE 4,500 FEET . Local Codes VCBV30 / VCBV20 / VCBV10 VCPV30 / VCPV18 / VCPV10 Certif ...

  • Vermont Casting VCPV18TP - 18 - page 4

    4 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Installation Installation Requirements Fresh Air for Combustion and V entilation W ARNING: This heater must have fresh air for proper opera- tion. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appli- ances ...

  • Vermont Casting VCPV18TP - 18 - page 5

    5 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale from manufacturer . This appliance is only for use with the type of gas indicated on the rating plate. This ...

  • Vermont Casting VCPV18TP - 18 - page 6

    6 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Connect to Gas Supply Before connecting the appliance, turn of all gas appli- ances. Close the main gas valve at the gas meter or Lp tank. Make certain there is good ventilation where the installation will be made. Installation should comply with all applicable building codes and ANSI Z223.1, ...

  • Vermont Casting VCPV18TP - 18 - page 7

    7 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Pressure Regulator 3/8” NPT Nipple T ee Joint Reducer Bushing to 1/8” NPT 1/8” NPT Plug T ab Heater Cabinet Ground Joint Union Manual Shutt-Off V alve From Gas Meter T est Gauge Connection T ee Joint Pipe Nipple Cap Sediment T rap Natural Gas (4” w .c. to 10.5” w .c. Pressure) LP Ga ...

  • Vermont Casting VCPV18TP - 18 - page 8

    8 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Lighting Instructions 1. Read the safety information. 2. Make sure manual shut-off valve is fully open. 3. Push in gas control knob slightly and turn clockwise to the OFF position. 4. W AIT 5 MINUTES TO CLEAR OUT ANY GAS. If you then smell gas, ST OP! Follow A in the safety information. If yo ...

  • Vermont Casting VCPV18TP - 18 - page 9

    9 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Pilot and Burner Inspection Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 1 1. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the he ...

  • Vermont Casting VCPV18TP - 18 - page 10

    10 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Problem When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition. ODS pilot lights but flame goes out when control knob is re ...

  • Vermont Casting VCPV18TP - 18 - page 11

    11 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater T roubleshooting, continued Problem Possible Cause Solution Heater produces a clicking noise just after burner is lit or turned off. Gas odor even when control knob is in OFF position. Gas odor during combustion. Heater shuts off on ODS 1. Metal expanding and contracting. 1. Gas leaks. Refer ...

  • Vermont Casting VCPV18TP - 18 - page 12

    12 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 3771 VCBVTN/ TP Unvented Room Heater 1. Guard Assembly RBW33XX0 RBW30XX0 RBW26XX0 2. Glass Panel RB ...

  • Vermont Casting VCPV18TP - 18 - page 13

    13 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Item / Model Number VCBV10TN/TP VCBV20TN/TP VCBV30TN/TP VCBVTN/ TP , continued 20. Fix Nut - Nozzle Holder RBM08XX0 RBM08XX0 RBM08XX0 21a. Main Nozzle - Natural RBM07XEO RBM07XA0 RBM07XC0 21b. Main Nozzle - LP RBM07XF0 RBM07XB0 RBM07XD0 22a. ODS Pilot Assembly (Daemyeong Korea) - Natural DS9 ...

  • Vermont Casting VCPV18TP - 18 - page 14

    14 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 3770 VCPVTN/ TP Unvented Room Heater 7 4 2 3 1 5 5 17 10 9 6 8 12 13 14 17 16 11 15 20a,b 18a,b 19 ...

  • Vermont Casting VCPV18TP - 18 - page 15

    15 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Contact V ermont Castings, Majestic Products with questions concerning prices and policies covering replacement parts. Parts may be ordered through you V ermont Castings distributor or dealer . Y ou will need the following information when ordering replacemet parts: • the appliance model n ...

  • Vermont Casting VCPV18TP - 18 - page 16

    16 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater © V ermont Castings, Majestic Products W arranty Service and Limited W arranty The V ermont Castings Majestic Products Company warrants this product to be free form defects in materi- als and components for two (2) years from the date of first purchase, provided that the product has been pr ...

メーカー Vermont Casting カテゴリー Gas Heater

Vermont Casting VCPV18TP - 18のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VCPV18TP - 18の取扱説明書
- Vermont Castingの製品カード
- パンフレット
- またはVermont Casting VCPV18TP - 18の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vermont Casting VCPV18TP - 18の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vermont Casting VCPV18TP - 18の取り付け説明書、サービスマニュアル、簡易説明書、またはVermont Casting VCPV18TP - 18のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vermont Casting VCPV18TP - 18の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vermont Casting VCPV18TP - 18デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVermont Casting VCPV18TP - 18を使用するのを助ける技術的文書のことです。説明書は通常、全てのVermont Casting VCPV18TP - 18ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vermont Castingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vermont Casting VCPV18TP - 18の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVermont Casting VCPV18TP - 18の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vermont Casting VCPV18TP - 18に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vermont Casting VCPV18TP - 18デバイスの基本機能を使うにあたってのヒント。 Vermont Casting VCPV18TP - 18のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vermont Casting VCPV18TP - 18に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVermont Casting VCPV18TP - 18のメーカー/サービスへの連絡先に関する情報。

Vermont Casting VCPV18TP - 18についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVermont Casting VCPV18TP - 18の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVermont Casting VCPV18TP - 18で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください