  • Miller Electric Intellifire 250 - page 1

    Intellifire 250 Processes Description Induction Heating Power Source Induction Heating OM-184 227K 2006 − 05 V isit our website at www.MillerWelds.com File: Induction Heating ...

  • Miller Electric Intellifire 250 - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .Mille ...

  • Miller Electric Intellifire 250 - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Induction Heating Hazards 1 . . . . . . . . ...

  • Miller Electric Intellifire 250 - page 4

    ...

  • Miller Electric Intellifire 250 - page 5

    OM-184 227 Page 1 SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage safety_ihom 5/05 Means Warning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special s ...

  • Miller Electric Intellifire 250 - page 6

    OM-184 227 Page 2 FIRE OR EXPLOSION hazard. D Do not overheat parts and adhesive. D W atch for fire; keep extinguisher nearby . D Keep flammables away from work area. D Do not locate unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not operate unit in explosive atmosphere. INDUCTION HE A TING can cause burns ...

  • Miller Electric Intellifire 250 - page 7

    OM-184 227 Page 3 1-6. EMF Information Considerations About Induction Heating And The Effects Of Low Fre- quency Electric And Magnetic Fields Th e following is a quotation from the General Conclusions Section of the U.S. Congress, Office of T echnology Assessment, Biological Effects of Power Frequency Electric & Magnetic Fields − Background P ...

  • Miller Electric Intellifire 250 - page 8

    OM-184 227 Page 4 SECTION 2 − MESURES DE SECURITE POUR LE CHAUFF AGE P AR INDUCTION ihom_fre 8/03 PRENDRE LES MESURES NECESSAIRES POUR EVITER LES RISQUES DE BLESSURES GRA VES, VOIRE MORTELLES. TENIR LES ENF ANTS A DIST ANCE. LES PORTEURS D’UN STIMULA TEUR CARDIAQUE DOIVENT PREALABLEMENT CONSUL TER LEUR MEDECIN. Pendant les opérations de chauf ...

  • Miller Electric Intellifire 250 - page 9

    OM-184 227 Page 5 DES FUMEES ET DES GAZ peuvent être dangereux pour votre santé. Le chauf fage à induction génère des fumées et des gaz. Leur inhalation peut être dangereuse pour votre santé. 1. Eloigner la tête des fumées. Ne pas respirer les fumées. 2. A l’interieur , ventiler la zone et/ou utiliser un extracteur pour l’évacuation ...

  • Miller Electric Intellifire 250 - page 10

    OM-184 227 Page 6 2-2. Informations concernant les champs électro-magnétiques (Information EMF) Considérations relatives au chauffage à induction et aux ef fets des champs électriques et magnétiques basse fréquence. Le texte suivant est extrait des conclusions générales Département du Congrès U.S., Office of T echnology Assessment, Effet ...

  • Miller Electric Intellifire 250 - page 11

    OM-184 227 Page 7 SECTION 3 − INST ALLA TION 3-1. Specifications Output Frequency Rated Output Required Reflective Inductance Amperes Input at Rated Load Output 50 or 60 Hz, Three-Phase Overall Dimensions W eight Frequency I n d uc t ance 460 V KV A KW 10 T o 50 kHz 25 kW At 100% Duty Cycle − Max 750 A (RMS), 700 V (RMS) 2.5 T o 50 μ h 39 0.29 ...

  • Miller Electric Intellifire 250 - page 12

    OM-184 227 Page 8 sb7.1* 3/93 - Ref. S-0004-A / Ref. S-0750 / Ref. ST -801 826-C 3-3. Remote 14 Receptacle RC14 Information and Connections 1 Front Panel 2 Plug 3 Threaded Collar 4 Keyway 5 Remote 14 Receptacle RC14 (See Section 3-4) T o connect to receptacle, align key- way , insert plug, and tighten threaded collar . 2 3 AJ B K I C L NH D M G E F ...

  • Miller Electric Intellifire 250 - page 13

    OM-184 227 Page 9 3-5. Connecting 3-Phase Input Power For Models With Customer Supplied Cord 803 766-A / Ref. ST-801 825-C 5/16 in 3/8 in T ools Needed: Y Installation must meet all National an d Local Codes − have only quali- fied persons make this installation. Y Disconnect and lockout/tagout in- put power before connecting input conductors fro ...

  • Miller Electric Intellifire 250 - page 14

    OM-184 227 Page 10 3-6. Electrical Service Guide 60 Hz Three Phase Input V oltage 460 Input Amperes At Rated Output 39 Max Recommended Standard Fuse Rating In Amperes 1 Time-Delay 2 45 Normal Operating 3 60 Min Input Conductor Size In A WG 4 8 Max Recommended Input Conductor Length In Feet (Meters) 287 (87) Min Grounding Conductor Size In A WG 4 10 ...

  • Miller Electric Intellifire 250 - page 15

    OM-184 227 Page 1 1 SECTION 5 − MAINTENANCE & TROUBLESHOOTING 5-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions. 3 Months Clean and tighten output connections. Repair or replace cracked cables and cords. 6 Months Replace damaged or unreadable labels. Blow out or vacuum inside. 5-2. ...

  • Miller Electric Intellifire 250 - page 16

    OM-184 227 Page 12 Ref. ST-801 826-A T ools Needed: 5-5. Measuring T uning Capacitor V oltage Y Significant AC voltage can remain on capacitors after unit is Off. Always check ALL capacitors as shown to be sure they have discharged before working on unit. 3/8 in T urn Of f power source and disconnect input power . Remove wrapper . 1 Tuning Capacito ...

  • Miller Electric Intellifire 250 - page 17

    OM-184 227 Page 13 Ref. ST-801 826-C / Ref. 801 828-C 5-6. Ground Fault Protection Ground fault protection circuitry automatically shuts down the power source output if a potentially hazardous condition exists at the heating device connected to the power source (e.g. insulation has broken down on a heating blanket causing the conductor to come into ...

  • Miller Electric Intellifire 250 - page 18

    OM-184 227 Page 14 Ref. ST-801 826-A T ools Needed: 5-7. Measuring Input Capacitor V oltage 3/8 in Y Significant DC voltage can remain on capacitors after unit is Off. Always check ALL capacitors as shown to be sure they have discharged before working on unit. T urn Of f power source and disconnect input power . Remove wrapper . 1 Input Capacitor C ...

  • Miller Electric Intellifire 250 - page 19

    OM-184 227 Page 15 5-8. Diagnostic LED’ s Ref. ST-801 826-B 1 Diagnostic LED’s Use diagnostic LED’ s to determine operating condition of power source. 2 Current Source Limit: 1 10 A Fault: 1 15 A 3 Over Frequency Limit: 50 kHz Fault: 55 kHz 4 Under Frequency Limit: 10 kHz Fault: 5 kHz 5 Current Reactive Limit: 700 A 6 T ank V oltage Limit: 67 ...

  • Miller Electric Intellifire 250 - page 20

    OM-184 227 Page 16 5-9. T roubleshooting T rouble Remedy No heat output. Replace building line fuse or reset circuit breaker . Secure head/coil connecting plate to power source connecting block (see Section 3-2). Check and replace Power switch if necessary . Connect power source to proper input voltage or check for low line voltage. No heat output; ...

  • Miller Electric Intellifire 250 - page 21

    OM-184 227 Page 17 Notes ...

  • Miller Electric Intellifire 250 - page 22

    OM-184 227 Page 18 SECTION 6 − ELECTRICAL DIAGRAM Figure 6-1. Circuit Diagram ...

  • Miller Electric Intellifire 250 - page 23

    OM-184 227 Page 19 204 963-A ...

  • Miller Electric Intellifire 250 - page 24

    OM-184 227 Page 20 SECTION 7 − P ARTS LIST . Hardware is common and not available unless listed. Figure 7-1. Main Assembly 801 828-F 1 Fig. 7-2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 23 24 25 27 38 39 40 12 33 31 32 30 34 35 36 37 28 42 41 26 29 ...

  • Miller Electric Intellifire 250 - page 25

    OM-184 227 Page 21 Quantity Description Part No. Dia. Mkgs. Item No. Figure 7-1. Main Assembly 1 179 245 P ANEL, side LH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 7-2 CENTER BAFFLE ASSEMBL Y 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Intellifire 250 - page 26

    OM-184 227 Page 22 Quantity Description Part No. Dia. Mkgs. Item No. Figure 7-2. Center Baffle Assembly (Fig 6-1 Item 2) 1 PM1,2 223 949 KIT , transistor IGBT module 75A 1200V 94 X 35.6MM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . PLG21,22 1 15 094 HOUSING PLUG & SKTS 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Intellifire 250 - page 27

    OM-184 227 Page 23 Quantity Description Part No. Dia. Mkgs. Item No. Figure 7-2. Center Baffle Assembly (Fig 6-1 Item 2)(Continued) 9 179 233 WINDTUNNEL LH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 L1 180 1 14 INDUCTOR, input 1 . . . . . . . . . . . . . . . ...

  • Miller Electric Intellifire 250 - page 28

    Notes ...

  • Miller Electric Intellifire 250 - page 29

    Notes ...

  • Miller Electric Intellifire 250 - page 30

    Notes ...

  • Miller Electric Intellifire 250 - page 31

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2006 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expe ...

  • Miller Electric Intellifire 250 - page 32

    PRINTED IN USA © 2006 Miller Electric Mfg. Co. 2006 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compan y 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarte rs − US A USA Phone: 920-735-4505 Aut o-At tended USA & Canada F AX : 920-735-4134 Int ernati onal F AX: 920-735-4125 European Headqua rters − ...

メーカー Miller Electric カテゴリー Welding System

Miller Electric Intellifire 250のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Intellifire 250の取扱説明書
- Miller Electricの製品カード
- パンフレット
- またはMiller Electric Intellifire 250の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miller Electric Intellifire 250の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miller Electric Intellifire 250の取り付け説明書、サービスマニュアル、簡易説明書、またはMiller Electric Intellifire 250のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miller Electric Intellifire 250の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miller Electric Intellifire 250デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiller Electric Intellifire 250を使用するのを助ける技術的文書のことです。説明書は通常、全てのMiller Electric Intellifire 250ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Miller Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miller Electric Intellifire 250の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiller Electric Intellifire 250の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miller Electric Intellifire 250に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miller Electric Intellifire 250デバイスの基本機能を使うにあたってのヒント。 Miller Electric Intellifire 250のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miller Electric Intellifire 250に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiller Electric Intellifire 250のメーカー/サービスへの連絡先に関する情報。

Miller Electric Intellifire 250についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiller Electric Intellifire 250の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiller Electric Intellifire 250で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)