Oregon Scientific BAR988HGAの取扱説明書

28ページ 2.2 mb
ダウンロード

ページに移動 of 28

Summary
  • Oregon Scientific BAR988HGA - page 1

    TREVISO Sleek Weather Station Model: BAR988HGA / BAR986HGA USER MANUAL BAR988HGA English Cover R5 9/18/04, 2:55 AM 1 ...

  • Oregon Scientific BAR988HGA - page 2

    EN 1 CONTENTS Introduction .............................................................. 3 Product Overview .................................................... 4 Front View .............................................................. 4 Back View .............................................................. 5 LCD Display ....................... ...

  • Oregon Scientific BAR988HGA - page 3

    EN 2 Backlight ................................................................. 22 Reset System ......................................................... 22 Safety and Care ...................................................... 22 W arnings ................................................................. 22 Tr oubleshooting ...................... ...

  • Oregon Scientific BAR988HGA - page 4

    EN 3 NOTE INTRODUCTION Thank you for selecting the Oregon Scientific TM BAR988HGA / BAR986HGA TREVISO Sleek W eather Station . This powerful device bundles time keeping, weather monitoring, indoor and outdoor temperature and humidity readings, barometric trends and altitude adjustment, into a single tool you can use from the convenience of your hom ...

  • Oregon Scientific BAR988HGA - page 5

    EN 4 PRODUCT OVERVIEW FRONT VIEW 1. LCD display 2. MODE: Change settings / display 3. MEMOR Y : V iew current, maximum and minimum temperature / humidity / UV readings 4. HISTOR Y : V iew historical barometer and UV readings 5. ALARM / : V iew alarm status; set alarm 6. SNOOZE / LIGHT : Activate 8-minute snooze or backlight 7. SELECT : Switch Areas ...

  • Oregon Scientific BAR988HGA - page 6

    EN 5 1. V entilation holes 2. Battery compartment (bottom) 3. AC adaptor socket 4. ° C / ° F switch (in battery compartment) 5. RESET button (in battery compartment) 6. mb / inHg switch (in battery compartment) Y ou can adjust the angle of the clock display as shown below: BACK VIEW 2 1 3 4 5 6 BAR988HGA English R5 9/18/04, 3:00 AM 5 ...

  • Oregon Scientific BAR988HGA - page 7

    EN 6 LCD DISPLA Y 1. W eather Forecast Area: Animated weather forecast 2. T emperature / Humidity / Comfort Zone Area: Readings and trend lines; comfort zone; sensor channel number 3. UVI / Barometer Area: UV level and barometric pressure bar chart; UV Index and barometric readings 4. Clock / Alarm / Calendar Area: Atomic clock; alarms; calendar 1 ...

  • Oregon Scientific BAR988HGA - page 8

    EN 7 W eather Forecast Area 1. Low battery icon for main unit 2. AC adaptor icon - displays when unplugged 3. Weather display 1 2 3 T emperature / Humidity / Comfort Zone Area 1. Selected Area icon 2. T emperature trend 3. Channel number (1-5) / reception status 4. Low battery icon for remote sensor 5. Humidity trend 6. MAX / MIN temperature 7. T e ...

  • Oregon Scientific BAR988HGA - page 9

    EN 8 UVI / Barometer Area 1. Barometric pressure is showing 2. UV is showing 3. Low battery icon for UV sensor 4. UVI value is showing 5. UV exposure time countdown has started 6. UV index level 7. UV exposure time for user 8. Barometer / UV chart 9. SPF applied to user for UV exposure 10. User skin type for UV exposure 11 . User no. (for UV Mode) ...

  • Oregon Scientific BAR988HGA - page 10

    EN 9 2 1 5 6 7 8 3 4 1 2 3 REMOTE SENSOR (RTGR328NA) 1. LCD display 2. LED status indicator 3. V entilation duct 1. Signal reception 2. US time zone 3. Channel number 4. Low battery icon 5. T ime 6. T emp ( ° C or ° F) 7. Humidity % 8. T emp / Humidity BAR988HGA English R5 9/18/04, 3:00 AM 9 ...

  • Oregon Scientific BAR988HGA - page 11

    EN 10 GETTING ST ARTED BA TTERIES Batteries are supplied with this product: • Main unit 4 x UM-4 (AAA) 1.5V • Remote unit 2 x UM-3 (AA) 1.5V Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit. Press RESET after each battery c ...

  • Oregon Scientific BAR988HGA - page 12

    EN 11 It is recommended that you use alkaline batteries with this product for longer performance. NOTE UNIT LOCA TION Main Weather Forecast Area Remote T emperature / Humidity Area UV Sensor UVI / Barometric Pressure Area AC ADAPT OR (MAIN UNIT) The batteries serve as a back-up power supply . For continuous use, please install the AC adaptor at the ...

  • Oregon Scientific BAR988HGA - page 13

    EN 12 SWITCH OPTION Channel If you are using more than one sensor , select a different channel for each sensor . 4. Press RESET . Then set the temperature unit. SWITCH OPTION T emp ° C / ° F To fold out the stand: 1 2 For best results: • Insert the batteries and select the unit, channel, and US time zone before you mount the sensor . • Place ...

  • Oregon Scientific BAR988HGA - page 14

    EN 13 The transmission range may vary and is subject to the receiving range of the main unit. Y ou may need to experiment with various locations to get the best results. SENSOR DA T A TRANSMISSION Data is sent from the sensor(s) every 60 Seconds. The reception icon shown in the T emperature / Humidity Area indicates the status. NOTE SEARCH FOR SENS ...

  • Oregon Scientific BAR988HGA - page 15

    EN 14 AT OMIC CLOCK The RTGR368NA remote sensor collects time and temperature information and transmits this back to the main unit. The current time and date is received by radio signal from the Atomic Clock broadcast located in Boulder , Colorado. For more information on the Atomic Clock, please visit www .nist.gov Initial reception takes 2-10 min ...

  • Oregon Scientific BAR988HGA - page 16

    EN 15 Atomic clock disabled: SET CLOCK The BAR988HGA / BAR986HGA and the RTGR368NA should automatically set and update the time, as necessary . However , if you are too far away from an Atomic Clock broadcast signal, or the product is unable to synchronize with the broadcast due to interference, you may need to set the clock manually . 1. Press SEL ...

  • Oregon Scientific BAR988HGA - page 17

    EN 16 2. Press ALARM / to view the alarm. ( AL will show at the top.) 3. Press and hold ALARM / for 2 seconds. 4. Select the hour and minute. Press UP or DOWN to change settings. 5. Press ALARM / to confirm. 6. The Daily Alarm icon will appear when the alarm is set. SET PRE-ALARM The Pre-Alarm can be set to sound 15, 30, 45, or 60 minutes before th ...

  • Oregon Scientific BAR988HGA - page 18

    EN 17 VIEW BAROMETER AREA Press SELECT to navigate to the Barometer Area. If is NOT shown, press MODE . Barometric data is shown in 2 areas at the bottom of the display . The upper area shows a 24-hour bar chart. The lower area shows current and historical readings. SELECT MEASUREMENT UNIT Slide the mb / inHg switch (in the clock battery compartmen ...

  • Oregon Scientific BAR988HGA - page 19

    EN 18 3. Press UP or DOWN to set the altitude in 33-foot increments (-328 ft to 8202 ft). 4. Press HISTOR Y to confirm. WEA THER FORECAST This product forecasts the next 12 to 24 hours of weather within a 19-31 mile (30-50 km) radius. The forecast is based on barometric pressure trend readings. The top area shows an animated icon indicating the for ...

  • Oregon Scientific BAR988HGA - page 20

    EN 19 UV data is shown in the same area as the Barometer . Press SELECT to navigate to the Barometer Area, then press MODE to display the UV icon and data. Refer to the UVR138A User Manual for more information and see below to learn about the new additional UV features. NEW ADDITIONAL UV FEA TURES UV EXPOSURE TIME COUNTDOWN To set the exposure time ...

  • Oregon Scientific BAR988HGA - page 21

    EN 20 The UV sensor must be activated before you try and set the additional features. Please refer to the UVR138A User Manual for more information. TEMPERA TURE AND HUMIDITY The weather station can display the following information from any of the 5 remote sensors: •C urrent, minimum, and maximum temperatures and relative humidity percentages. ? ...

  • Oregon Scientific BAR988HGA - page 22

    EN 21 TEMPERA TURE AND HUMIDITY TREND The trend lines are shown next to the temperature and humidity readings. COMFORT ZONE The Comfort Zone indicates how comfortable the climate is, based on current temperature and humidity measurements. TREND RISING STEADY F ALLING TEMPERA TURE HUMIDITY HEA T INDEX The Heat Index advises 4 levels of warning if th ...

  • Oregon Scientific BAR988HGA - page 23

    EN 22 BACKLIGHT Press SNOOZE / LIGHT to illuminate the backlight for 8 seconds. RESET SYSTEM The RESET button is located at the bottom of the unit. Press RESET when you change the batteries and whenever performance is not behaving as expected (for example, unable to establish radio frequency link with remote unit or radio-controlled clock). When yo ...

  • Oregon Scientific BAR988HGA - page 24

    EN 23 TROUBLESHOOTING SPECIFICA TIONS Main Unit Dimensions L x W x H 4.72 x 3.39 x 7.40 inches (120 x 86 x 188 mm) W eight 0.83 lbs (376 grams) without battery Remote Unit Dimensions L x W x H 2.76 x 0.96 x 4.57 inches (70 x 24.5 x 1 16 mm) W eight 0.24 lbs (108 grams) without battery T emperature Unit ° F or ° C Indoor Range 23 ° F to 122 ° F ...

  • Oregon Scientific BAR988HGA - page 25

    EN 24 Comfort 40% to 70% Memory Min / max Barometer Unit mb / hPa or inHg Resolution 1 mb (0.03 inHg) Altitude -328 to 8202 feet (-100 to 2500 meters) Display Sunny (day / night), partly cloudy (day / night), cloudy , rainy , snowy Remote Unit (RTGR328NA) RF frequency 433 MHz Range Up to 230 feet (70 meters) with no obstructions T ransmission Appro ...

  • Oregon Scientific BAR988HGA - page 26

    EN 25 ABOUT OREGON SCIENTIFIC V isit our website ( www .oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact ...

  • Oregon Scientific BAR988HGA - page 27

    EN 26 • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver . • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio / TV technician for help. DECLARA TION OF CONFORMITY The information below ...

  • Oregon Scientific BAR988HGA - page 28

    © 2004 Oregon Scientific. All rights reserved. 086-000000-000 BAR988HGA English Back R5 9/18/04, 1:24 AM 1 ...

メーカー Oregon Scientific カテゴリー Weather Radio

Oregon Scientific BAR988HGAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BAR988HGAの取扱説明書
- Oregon Scientificの製品カード
- パンフレット
- またはOregon Scientific BAR988HGAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Oregon Scientific BAR988HGAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Oregon Scientific BAR988HGAの取り付け説明書、サービスマニュアル、簡易説明書、またはOregon Scientific BAR988HGAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Oregon Scientific BAR988HGAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Oregon Scientific BAR988HGAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOregon Scientific BAR988HGAを使用するのを助ける技術的文書のことです。説明書は通常、全てのOregon Scientific BAR988HGAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Oregon Scientificの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Oregon Scientific BAR988HGAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOregon Scientific BAR988HGAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Oregon Scientific BAR988HGAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Oregon Scientific BAR988HGAデバイスの基本機能を使うにあたってのヒント。 Oregon Scientific BAR988HGAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Oregon Scientific BAR988HGAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOregon Scientific BAR988HGAのメーカー/サービスへの連絡先に関する情報。

Oregon Scientific BAR988HGAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOregon Scientific BAR988HGAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOregon Scientific BAR988HGAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)