  • Omega Vehicle Security OMG-COMM232-PCI - page 1

    www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-COMM232-PC I Dual Por t PCI RS-232 Inter face Board Shop online at ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 2

    Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sale ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 3

    Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED ................................................................................ 1 F ACTORY D EFAULT S ETTINGS ......... ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 4

    A PPENDIX F - C OMPLIANCE N OTICES .....................................16 F EDERAL C OMMUNICATIONS C OMMISSION S TATEMENT ............ 16 EMC D IRECTIVE S TATEMENT ........................................................... 16 Figures Figure 1 - Clocking Mode 'Divide By 4’ ............................................................ 2 Figur ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 5

    Introduction Omega Engineering COMM+232.PCI Page 1 Introduction Overview The Omega Engineering OMG - COMM+232.PCI is a two channel PCI Bus serial I/O adapter for the PC and compatibles. It provi des two RS-232 serial ports supporting data rates up to 460.8K bps. The OMG - COMM+232.PCI works seamlessly with the standard operating system serial drive ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 6

    Card Setup Omega Engineering COMM+232.PCI Page 2 Card Setup Address and IRQ selection The OMG - COMM+232.PCI is automatically assigned I/O addresses and IRQs by your motherboard BIOS. Only the I/O address may be modified by the user. Adding o r removing other hardware may change the assignment of I/O addresses and IRQs. Clock Modes The OMG - COMM+2 ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 7

    Card Setup Omega Engineering COMM+232.PCI Page 3 To double these rates up to a maximum rate of 230.4K bps place the jumper in the divide by 2 (silk - screen DIV2) position. DIV1 DIV2 DIV4 Figure 2 - Clocking Mod e 'Divide By 2’ Baud Rates and Divisors for the ‘DIV2’ mode The following table shows some common data rates and the rates you ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 8

    Notes Page Omega Engineering COMM+232.PCI Page 4 ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 9

    Card Setup Omega Engineering COMM+232.PCI Page 5 To select the maximum data rate (460.8K bps) place the jumper in t he divide by 1 (silk - screen DIV1) position. DIV1 DIV2 DIV4 Figure 3 - Clocking Mode 'Divide By 1’ Baud Rates and Divisors for the ‘DIV1’ mode The following table shows some common data rates and the rates you should choos ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 10

    Notes Page Omega Engineering COMM+232.PCI Page 6 ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 11

    Installation Omega Engineering COMM+232.PCI Page 7 Installation Operating System Installation Windows 95/98/NT Run Setup on Disk 2 of the Serial Utilities Software. Windows 3.1x Refer to the Win3x.hlp file in the Win31 directory on D isk 1 of the Serial Utilities Software. DOS Refer to the Readme.txt file found in the DOS directory on Disk 1 of ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 12

    Technical Description Omega Engineering COMM+232.PCI Page 8 Technical Description The Omega Engineering OMG - COMM+232.PCI provides a PCI interface adapter with 2 asynchronous serial ports providing a versatile interface for modems, printers and plotters. The OMG - COMM+232.PCI utilizes the 16550 UART. This chip features progr ammable baud rates, d ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 13

    Technical Description Omega Engineering COMM+232.PCI Page 9 polling’. This method required the interrupt service routine to ‘poll’ or interrogate each UART as to its interrupt pending status. This met hod of polling was sufficient for use with slower speed communications, but as modems increased their throughput abilities this method of servi ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 14

    Specifications Omega Engineering COMM+232.PCI Page 10 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 1 58º F) Humidity Range 10 to 90% R.H. Non - Condensing 10 to 90% R.H. Non - Condensing Manufacturing • All Omega Engineering Printed Circui ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 15

    Appendix A - Troubleshooting Omega Engineering COMM+232.PCI Page 11 Appendix A - Troubleshooting A Serial Utility Diskette is supplied with the Omega Engineering adapter and will be used in the t roubleshooting procedures. By using this diskette and following these simple steps, most common problems can be eliminated without the need to call Techni ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 16

    Appendix B - How To Get Assistance Omega Engineering COMM+232.PCI Page 12 Appendix B - How To Get Assistance Please refer to Appendix A - Troubleshooting prior to calling Technical Suppor t. 1. Read this manual thoroughly before attempting to install the adapter in your system. 2. When calling for technical assistance, please have your user manual ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 17

    Appendix C – Electrical Interface Omega Engineering COMM+232.PCI Page 13 Appen dix C - Electrical Interface RS - 232 Quite possibly the most widely used communication standard is RS - 232. This implementation has been defined and revised several times and is often referred to as RS - 232 or EIA/TIA - 232. The IBM PC computer defined the RS - 2 32 ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 18

    Appendix D - Asynchronous Communications Omega Engineering COMM+232.PCI Page 14 Appendix D - Asynchronous Communications Serial data communications implies that indiv idual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (sta ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 19

    Appendix E - Silk - Screen Omega Engineering COMM+232.PCI Page 15 Appendix E - Silk - Screen 5.0" 4.2" ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 20

    Warranty Omega Engineering COMM+232.PCI Page 16 Appendix F - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 21

    W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OME GA ? ...

  • Omega Vehicle Security OMG-COMM232-PCI - page 22

    M 3107 /0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, ...

メーカー Omega Vehicle Security カテゴリー Network Card

Omega Vehicle Security OMG-COMM232-PCIのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- OMG-COMM232-PCIの取扱説明書
- Omega Vehicle Securityの製品カード
- パンフレット
- またはOmega Vehicle Security OMG-COMM232-PCIの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Vehicle Security OMG-COMM232-PCIの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Vehicle Security OMG-COMM232-PCIの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Vehicle Security OMG-COMM232-PCIのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Vehicle Security OMG-COMM232-PCIの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Omega Vehicle Security OMG-COMM232-PCIデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Vehicle Security OMG-COMM232-PCIを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Vehicle Security OMG-COMM232-PCIユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Vehicle Securityの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Vehicle Security OMG-COMM232-PCIの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Vehicle Security OMG-COMM232-PCIの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Vehicle Security OMG-COMM232-PCIに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Vehicle Security OMG-COMM232-PCIデバイスの基本機能を使うにあたってのヒント。 Omega Vehicle Security OMG-COMM232-PCIのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Vehicle Security OMG-COMM232-PCIに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Vehicle Security OMG-COMM232-PCIのメーカー/サービスへの連絡先に関する情報。

Omega Vehicle Security OMG-COMM232-PCIについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Vehicle Security OMG-COMM232-PCIの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Vehicle Security OMG-COMM232-PCIで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)