Olympus X-Press V - page 1
S ingle U se Cannula V S ingle U se Cannula V ...
-
Olympus X-Press V - page 2
T aper (PR-V435Q) Standard (PR-V416Q) Shor t taper (PR-V418Q) Slit (PR-V427Q) Ball Tip (PR-V223Q) T aper (PR-V434Q) Shor t taper (PR-V414Q) Long taper (PR-V420Q) The V -System is a complete system that integrates O lympus endoscopes and EndoTherapy devices. The revolutionar y V- S ystem design offers the option of guide wire manipulation by the phy ...
-
Olympus X-Press V - page 3
Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-18, 20097 Hamburg, Germany 6100 Blue Lagoon Drive, Suite 390 Miami, Florida 33126-2087, U ...
-
Olympus X-Press V - page 4
Si ngle U se 3-Lumen E xtraction Balloon V ...
-
Olympus X-Press V - page 5
B The guidewire and injection lumens are separated to ensure smoother passage of the guidewire. A dditionally , contrast media can be injected without remo ving the guidewire. T wo models are available — one with the injection port located above the balloon and the other with the injection port located below the balloon. T riple-lumen design allo ...
-
Olympus X-Press V - page 6
B The guidewire and injection lumens are separated to ensure smoother passage of the guidewire. A dditionally , contrast media can be injected without remo ving the guidewire. T wo models are available — one with the injection port located above the balloon and the other with the injection port located below the balloon. T riple-lumen design allo ...
-
Olympus X-Press V - page 7
S pacif ications Model B-V231P-B B-V231P-A Injection port Balloon diameter Sheath Working length Minimum channel size Compatible guidewire Radiopaque band Syringes Below 8.5mm/11.5mm/15.0mm Distal end 5.5Fr/Proximal end 7Fr 1900mm 2.8mm min 0.89mm(0.035inch) One band at the distal end and one band at the proximal end of balloon Three(3)syringes in ...
-
Olympus X-Press V - page 8
Single Use Retriev al Basket V Single Use Retriev al Basket V ...
-
Olympus X-Press V - page 9
Injection port for contrast media facilitates fluoroscopic visualization. S terile single-use design for convenience both before and after procedur es. Eight-wire basket designed for the capture and remov al of small stones. Four-wire basket design for versatile retrie val Rotation mechanism and bu llet-shaped tip Wire guided ability for su ...
-
Olympus X-Press V - page 10
An emergency device, this is only to be used in the unlikely event of basket impaction due to an extremely hard calculus. Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan Postfach 10 49 08, ...
-
Olympus X-Press V - page 11
S ingle U se 2-Lumen S phincterotome V S ingle U se 3-Lumen S phincterotome V ...
-
Olympus X-Press V - page 12
Ex ceptional C utting P erformance and Easy , F ast Ex change Capabilit y for Enhanced E f f iciency in ER CP S phincterotomy Distal marking on the sheath for impro ved view field visibility The distal marking on the sheath clearly indicates both the center and cutting position of the knife. Injection lumen Guidewire lumen Cutting wire lumen Sheath ...
-
Olympus X-Press V - page 13
Ex ceptional C utting P erformance and Easy , F ast Ex change Capabilit y for Enhanced E f f iciency in ER CP S phincterotomy T apered tip design for smooth insertion into strictures and the minor papilla (KD-V431Q series only) Pre-curved distal end fo r easier knife positioning Distal marking on the sheath for impro ved view field visibility The d ...
-
Olympus X-Press V - page 14
Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-18, 20097 Hamburg, Germany 6100 Blue Lagoon Drive, Suite 390 Miami, Florida 33126-2087, U ...
-
Olympus X-Press V - page 15
DISPOSABLE GUIDEWIRE ...
-
Olympus X-Press V - page 16
An Essential T ool to achieve a N ew Level of Ef f iciency in B iliar y-P ancr eatic P rocedur es. Designed to Enhance the R evolutionar y Exchange C apability of the V -System. 130mm Ring-marker section Spiral-marker section Ring-markers are visible from 50mm to 120mm from the distal end to help determine duct penetration. 50mm 120mm 400mm 2700mm ...
-
Olympus X-Press V - page 17
An Essential T ool to achieve a N ew Level of Ef f iciency in B iliar y-P ancr eatic P rocedur es. Designed to Enhance the R evolutionar y Exchange C apability of the V -System. Specially coated to insure smooth wire manipulation To ensure smooth passage through tight strictur es in the bile duct, the distal 500mm from the tip is coated with a spec ...
-
Olympus X-Press V - page 18
Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-18, 20097 Hamburg, Germany 6100 Blue Lagoon Drive, Suite 390 Miami, Florida 33126-2087, U ...
Olympus X-Press Vについてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもOlympus X-Press Vの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOlympus X-Press Vで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。