    Operating and Installation Instructions Downdraft Ventilation System DA 6480, DA 6490 DAG 500, DAG 1000 To prevent accidents and appliance damage, read these instructions before installation or use. M.-Nr. 09 045 140 en - US, CA ...

  • Miele DA 6480 - page 2

    IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Description of the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Operation . . . . . . . ...

  • Miele DA 6480 - page 3

    READ AND SAVE THESE INSTRUCTIONS Keep these operating instructions in a safe place and pass them on to any future user. Read these Instructions carefully before installing or using the Ventilation System. ~ This appliance is intended for residential use only. Use the appliance only for its intended purpose. ~ This appliance complies with current sa ...

  • Miele DA 6480 - page 4

    ~ d) Before connecting the appliance to the power supply make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. If in doubt consult a qualified electrician. ~ e) Installation work and repairs should only be performed by a qualified tec ...

  • Miele DA 6480 - page 5

    , WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING * : ~ a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS . If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. ~ b) NEVER PICK UP A FLAM ...

  • Miele DA 6480 - page 6

    Installation , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Installation work and electrical wiring must be done by qualified persons in accordance with all applicable codes and standards, including fire-rated construction. ~ b) Sufficient air is needed for combustion and exhausting of gases ...

  • Miele DA 6480 - page 7

    The ventilation system offers two installation options: with the internal DAG 500 exhaust blower (not included) The air is drawn through and cleaned by the grease filters and then directed outside. with the DAG 1000 external blower (not included) The air is drawn through and cleaned by the grease filters and then directed outside. The external blow ...

  • Miele DA 6480 - page 8

    Description of the appliance 8 ...

  • Miele DA 6480 - page 9

    a On/Off button for the retractable vent and fan b Control panel c Retractable vent d Grease filter e Exhaust blower DAG 500 (not included) The exhaust blower can also be installed behind the appliance. f Vent collar The vent collar can be installed so that the exhaust vents to either side, downwards, or to the rear. g Temperature warning light The ...

  • Miele DA 6480 - page 10

    Raising the vent / Turning on the fan ^ Press the On/Off button on the top of the ventilation system. The vent will rise. The fan will start at power level 2. The fan will automatically turn off if it is blocked while rising or retracting. When the obstruction is removed, press the On/Off button on the top of the appliance to restart it. Selecting ...

  • Miele DA 6480 - page 11

    Temperature warning § The ventilation system can become very hot during operation. It can cause burns, particularly when cooking with gas. The ventilation system is equipped with a temperature sensor. The warning light § above the control panel will flash when the temperature of the housing exceeds 113 °F (45°C). When this happens, do not touch ...

  • Miele DA 6480 - page 12

    Before cleaning or servicing the ventilation system, disconnect it from the power supply, see "Important Safety Instructions". Cleaning the casing Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the ventilation system. They will damage the surface. ^ All external surfaces and controls can be cleaned wi ...

  • Miele DA 6480 - page 13

    Special instructions for control buttons The controls may change or become discolored if not cleaned regularly, clean soiled areas immediately. Do not use a stainless steel cleaner on the controls. Grease filters The reusable metal grease filters remove solid particles from the vented kitchen air (grease, dust, etc). This helps keep the ventilation ...

  • Miele DA 6480 - page 14

    Cleaning the grease filters ^ By hand: use a scrub brush with a solution of warm water and mild dish soap. Do not use the pure detergent, aggressive all purpose cleaners, oven sprays, abrasive cleaning agents or limescale removers. They could damage the filter. ^ In a dishwasher: place the filter vertically in the lower basket, making sure that the ...

  • Miele DA 6480 - page 15

    Repairs In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department. ^ When contacting the Technical Service Department, please have the model and serial number of your appliance available. These can be found on the data plate located on the housing above the connection box. After Sales Servic ...

  • Miele DA 6480 - page 16

    16 ...

  • Miele DA 6480 - page 17

    Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our ...

  • Miele DA 6480 - page 18

    18 ...

  • Miele DA 6480 - page 19

    Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. , DANGER Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept out of the reach of babies and young children. Danger of suffocation! Disposal ...

  • Miele DA 6480 - page 20

    Appliance dimensions 20 ...

  • Miele DA 6480 - page 21

    a DAG 500 Internal blower The blower box can be mounted in such a way that the vent collar is aligned to the left, the right, downwards or towards the rear, as desired. b Connection plate when using the DAG 1000 external blower The blower or the connection plate can also be mounted in the same position on the rear of the appliance. x = Distance to ...

  • Miele DA 6480 - page 22

    Cabinet dimensions Appliance dimensions 22 ...

  • Miele DA 6480 - page 23

    Exhaust air ducting using the DAG 500 internal blower, installed on the front of the appliance [vent duct 6" C (150 mm)]: a to the left or right, b downwards, c to the rear. If the blower is being installed at the rear of the appliance, a cut-out must be made in the rear of the cabinet or wall where it will be mounted and the appropriate clear ...

  • Miele DA 6480 - page 24

    Installation using the DAG 500 internal blower DAG 500 mounted in front of the exhaust system. DAG 500 mounted behind the exhaust system. Note that the blower must be accessible to install the venting ductwork. Appliance dimensions 24 ...

  • Miele DA 6480 - page 25

    Installation using the DAG 1000 external blower connection plate Exhaust air ducting to the front. Exhaust air ducting to the rear. Note that the back must be accessible for the installation of the vent duct. Appliance dimensions 25 ...

  • Miele DA 6480 - page 26

    The ventilation system is installed directly behind the cooktop. For easiest installation, install the ventilation system first, then the cooktop. The ventilation system must not be installed in an area where there are strong drafts, for instance near windows, doors, etc. Before installation, please read the "Appliance dimensions" and &qu ...

  • Miele DA 6480 - page 27

    ^ With the assistance of another person, lift the appliance into the prepared cutout. The top mounting brackets should rest on the countertop. ^ Secure the appliance to the countertop with 2 screws. Alternatively, or additionally, the appliance can also be attached underneath the countertop with the angle brackets provided. ^ First, loosely screw t ...

  • Miele DA 6480 - page 28

    ^ Remove the screws from the countertop. ^ Lift the appliance back out of the cabinet. ^ Pre-drill the marked mounting holes on the cabinet floor. ^ Tighten the mounting brackets on the appliance at the marked position. ^ Lay the vent housing on the floor on a blanket or other suitable protection in order to mount the DAG 500 blower or DAG 1000 blo ...

  • Miele DA 6480 - page 29

    Venting direction towards the rear: In this case, the DAG 500 blower box must be modified. ^ Loosen the two screws holding the blower in the box. ^ Take the blower out of the box. ^ Remove the small cover on the rear of the ventilation system. ^ Mount the blower on the front of the ventilation system housing using the 2 screws while positioning the ...

  • Miele DA 6480 - page 30

    ^ Plug the connection cable from the ventilation system into the blower motor. ^ Remove the vent collar of the blower box. ^ Close the opening in the blower box with the cover you removed from the rear of the ventilation system housing. Fasten it with 4 screws. ^ Mount the vent collar on the rear of the ventilation system. ^ Mount the blower box to ...

  • Miele DA 6480 - page 31

    Installing the DAG 500 blower box on the rear The blower box can also be installed on the back of the ventilation system: ^ Remove the large cover on the rear. Mounting is the same as if installing on the front. ^ Mount the blower on the rear the same way as described for mounting on the front. ^ When finished, mount the previously removed cover on ...

  • Miele DA 6480 - page 32

    Preparing the electrical connection ^ Remove the cover of the terminal box. ^ Decide whether you would like the power cable to enter the ventilation system from below or from the rear. Remove the respective knock-out. ^ If the system is connected to an external blower, remove the knock-out for the control cable. ^ Install a suitable UL listed cable ...

  • Miele DA 6480 - page 33

    ^ Remove the protective plastic from the side cover. ^ Push the side covers in place on the mounting brackets and engage them. ^ Connect the appliance to the electric power supply. Observe the "Important safety instructions" and "Electrical connection" warnings. ^ Press the On/Off button on the top of the ventilation system. The ...

  • Miele DA 6480 - page 34

    Installation with the DAG 1000 external blower If using DAG 1000 external blower, a connection plate much be installed on the ventilation system instead of the blower box. It can be mounted on either on the front or the rear of the appliance. If the connection plate is mounted on the front, the exhaust can only be vented to the front. If the connec ...

  • Miele DA 6480 - page 35

    , WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the ventilation system should be only vented to the outside of the building. Do not vent exhaust air into spaces within walls or ceilings or i ...

  • Miele DA 6480 - page 36

    Never connect a ventilation system to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting the ventilation system to an existing, inactive chimney or vent flue. Important If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to ...

  • Miele DA 6480 - page 37

    , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the ap ...

  • Miele DA 6480 - page 38

    Electrical connection if using an external blower If using the external blower, install a connection cable between the ventilation system and the external blower. Please follow the Operating and Installation Instructions for the DAG 1000. ^ Additional housing knock-outs should be used for the external blower housing. ^ Install a suitable UL listed ...

  • Miele DA 6480 - page 39

    39 ...

  • Miele DA 6480 - page 40

    Alteration rights reserved / 1711 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION. M.-Nr. 09 045 140 / 01 ...

メーカー Miele カテゴリー Ventilation Hood

Miele DA 6480のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DA 6480の取扱説明書
- Mieleの製品カード
- パンフレット
- またはMiele DA 6480の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miele DA 6480の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miele DA 6480の取り付け説明書、サービスマニュアル、簡易説明書、またはMiele DA 6480のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miele DA 6480の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miele DA 6480デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiele DA 6480を使用するのを助ける技術的文書のことです。説明書は通常、全てのMiele DA 6480ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mieleの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miele DA 6480の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiele DA 6480の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miele DA 6480に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miele DA 6480デバイスの基本機能を使うにあたってのヒント。 Miele DA 6480のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miele DA 6480に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiele DA 6480のメーカー/サービスへの連絡先に関する情報。

Miele DA 6480についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiele DA 6480の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiele DA 6480で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)