  • Amcor 10KE-410 - page 1

    PORT ABLE AIR CONDITIONER AMC 7KE-410 10KE-410 12KE-410 GB Portable air conditioner ...

  • Amcor 10KE-410 - page 2

    2 1. Control panel 2. Air outlet 3. Handle 4. C asters 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. C ord hanger 9. W ater stopper (plug inside) 10. F oam extension 11. F oam with hole 12. W ater tray 13. Hose adapter 14. Window/wall adapter 15. C ap 16. Exhaust hose 17. W ater tube 18. Remote control GB PA R TS 18 ...

  • Amcor 10KE-410 - page 3

    3 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer . Before you use your air conditioner you should carefully read these instructions to maximise this p ...

  • Amcor 10KE-410 - page 4

    4 POS I TI ON IN G GB This unit is portable and can easily be moved from one room to another . In doing so keep this in mind: • The air conditioner must stand upright on an even surface. • Position not (near) bath, douche or other wet or damp area. • Keep for free air circulation at least 50 cm free from any obstacle or curtains. • Never op ...

  • Amcor 10KE-410 - page 5

    5 GB • Put the exhaust hose into the round side of the exhaust hose adapter (13) (fig. 1). • Put the wall/window adapter (14) onto the exhaust hose (fig. 2). • C onnect the hose with the rectangular end to the air conditioner (fig. 4). Using the foam. Place the foam with the hole (11), if needed together with the foam extension (10), in the w ...

  • Amcor 10KE-410 - page 6

    6 OPER A TION GB 1. ON/OFF Press the ON/OFF-button to switch the unit on or off. The unit selects the operating mode depending on the room temperature: - with an ambient temperature h igher than 23 °C, cooling mode is selected - is the ambient temperature b etween 20 °C and 23 °C, then will fan mode be active. 2. Timer button Use this button to ...

  • Amcor 10KE-410 - page 7

    7 Remote control The air conditioner can be operated with the remote control. T wo AAA- batteries are required to use the remote control. Point the remote control hand set towards the control panel of the unit and press the relevant button, the red LED on the hand set will flash whenever a button is pressed. Air flow a. T urn the roller to control ...

  • Amcor 10KE-410 - page 8

    8 GB Switch off the unit and remove the plug from the mains. • Remove the drain knob and the rubber plug. • C onnect the correct water tube onto the water outlet. • Place the other end in a normal drain. • Make sure that the tube is free from twists and bends. The tube must incline over its entire length. Dehumidification If the unit will b ...

  • Amcor 10KE-410 - page 9

    9 GB ST ORA GE See the instructions "Emptying the water container" on page 7. • Drain the condensed water completely . • Clean (or replace) the filter . • Put the unit on a sunny day in fan mode for a couple of hours to ensure that the inside becomes completely dry . • Store the power cable as shown, protect the unit against dust ...

  • Amcor 10KE-410 - page 10

    10 GB Model AMC 7KE-410 AMC 10KE-410 AMC 12KE-410 Cooling capacity BTU/h 6500 8300 9600 kW 1.9 2.4 2.8 Mains 220–240 V / 50 Hz / 1Ph Power consumption W 690 830 1030 Current A 3 3.7 4.5 Dehumidification L/24h 24 28.8 36 Air delivery m 3 /h 300 350 350 Recommended room size m 2 12 18 24 Refrigerant R410A Compressor rotary F an speeds 2 Thermostat ...

  • Amcor 10KE-410 - page 11

    0 5 2 4 2 1 3 1 9 C M A Hong Kong China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgro ...

  • Amcor 10KE-410 - page 12

    ...

  • Amcor 10KE-410 - page 13

    2 1. Control panel 2. Air outlet 3. Handle 4. C asters GB PA R TS 15 14 11 12 10 13 16 17 5 8 7 9 6 4 1 2 3 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. C ord hanger 9. W ater stopper (plug inside) 10. F oam extension 11. F oam with hole 12. W ater tray 13. Hose adapter 14. Window/wall adapter 15. C ap 16. Exhaust hose 17. W ater tube ...

  • Amcor 10KE-410 - page 14

    3 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer . Before you use your air conditioner you should carefully read these instructions to maximise this p ...

  • Amcor 10KE-410 - page 15

    4 ...

  • Amcor 10KE-410 - page 16

    5 POS I TI ON IN G GB This unit is portable and can easily be moved from one room to another . In doing so keep this in mind: • The air conditioner must stand upright on an even surface. • Position not (near) bath, douche or other wet or damp area. • Keep for free air circulation at least 50 cm free from any obstacle or curtains. Installation ...

  • Amcor 10KE-410 - page 17

    6 ON/OFF and timer function T urn the control [1] to switch the unit on or off. When the unit is on, LED-1 is on. Timer function Use control [1] to set a working time between 1 and 8 hours. The unit switches off when the set time has run down. Mode selection and speed setting Select with control [2] the required operating mode cooling or fan mode. ...

  • Amcor 10KE-410 - page 18

    7 GB When the water container is full, the compressor and the ventilator stop functioning, LED [4] will lit. Switch off the unit and remove the plug from the mains. • Place the water tray flat on the floor under the drain. • Remove the drain knob. • Remove the rubber plug and fill the water tray then replace the plug to stop the water flow . ...

  • Amcor 10KE-410 - page 19

    8 Important: how to wire a 13 amp plug The wires in the mains lead on this appliance are coloured in accordance with the following code: G REEN AND Y ELLOW – E ARTH B LUE – N EUTRAL B ROWN – L IVE As the colours may not correspond with the markings identifying the terminals in your plug proceed as follows: The G REEN AND Y ELLOW wire must be ...

  • Amcor 10KE-410 - page 20

    9 GB Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of warranty and can endanger the user . Problem C ause Solution The unit does not function Check the plug fuse. Check the mains outlet by connecting another appliance Connect to a functioning outlet and switch on W ater container indicator is on E ...

  • Amcor 10KE-410 - page 21

    10 Amcor products have a lower than industry norm failure rate, as we have strict quality control in our factory . However we are not 100% perfect and occasionally units can fail. When they do we have a simple returns procedure. All Amcor products are guaranteed for one-year from date of purchase, on a back to base principle. A copy of our guarante ...

  • Amcor 10KE-410 - page 22

    11 YOUR GUARANTEE DOMESTIC AIR CONDITIONERS If this product is found to be defective as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge. This guarantee is subject to the following terms: Amcor Limited., must be notified of the fault Proof of purchase must be presented ...

  • Amcor 10KE-410 - page 23

    0 2 3 4 2 1 3 1 9 C M A Hong Kong China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgro ...

メーカー Amcor カテゴリー Air Conditioner

Amcor 10KE-410のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 10KE-410の取扱説明書
- Amcorの製品カード
- パンフレット
- またはAmcor 10KE-410の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Amcor 10KE-410の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Amcor 10KE-410の取り付け説明書、サービスマニュアル、簡易説明書、またはAmcor 10KE-410のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Amcor 10KE-410の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Amcor 10KE-410デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmcor 10KE-410を使用するのを助ける技術的文書のことです。説明書は通常、全てのAmcor 10KE-410ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Amcorの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Amcor 10KE-410の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmcor 10KE-410の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Amcor 10KE-410に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Amcor 10KE-410デバイスの基本機能を使うにあたってのヒント。 Amcor 10KE-410のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Amcor 10KE-410に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmcor 10KE-410のメーカー/サービスへの連絡先に関する情報。

Amcor 10KE-410についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmcor 10KE-410の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmcor 10KE-410で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)