Pelco ICIMI1000の取扱説明書

16ページ 0.07 mb
ダウンロード

ページに移動 of 16

Summary
  • Pelco ICIMI1000 - page 1

    ICIMI1000 Inter face Cable Installation/ Operation Manual C 1014M -B ( 10 /97) ® Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 Inter Check ✓ by ® ...

  • Pelco ICIMI1000 - page 2

    16 Pelco Manual C1014M-B (10/97) ii CONTENTS Section Page 1.0 GENERAL .................................................................................................. 1 1.1 IMPORT ANT SAFEGUARDS AND WARNINGS ............................... 1 1.2 UNP ACKING INSTRUCTIONS .......................................................... 2 2.0 DESCRIPTION . ...

  • Pelco ICIMI1000 - page 3

    Pelco Manual C1014M-B (10/97) 1 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should only be done by Qualified ...

  • Pelco ICIMI1000 - page 4

    2 Pelco Manual C1014M-B (10/97) 1.2 UNP ACKING INSTRUCTIONS Unpack and inspect all parts carefully . The following items are supplied: 1 ICIMI1000 Interface Cable 1 Installation/Operation Manual (C1014M-B) 1 Interface Extension Cable Be sure to save the shipping carton, boxes and inserts. They are the safest mate- rial in which to make future shipm ...

  • Pelco ICIMI1000 - page 5

    Pelco Manual C1014M-B (10/97) 3 2.0 DESCRIPTION The information in this manual covers the installation and operation of the Inter-Check ® ICIMI1000 Interface Cable with the following systems: Gilbarco TCR/15 and “G-Site” cash registers Koppens/Schlumberger Micromax 1000/2000/3000 Pro cash registers Suntronics Station Minder 890, 960, 2000 cash ...

  • Pelco ICIMI1000 - page 6

    4 Pelco Manual C1014M-B (10/97) 3.0 INST ALLA TION FOR CASH REGISTERS This section covers the installation of the ICIMI1000 interface cable with the Gilbarco TCR/15 and “G-Site”; Koppens/Schlumberger Micromax 1000, 2000, 3000 Pro; Suntronics Station Minder 890, 960, 2000; and V erifone Ruby Super System cash registers. The following should be n ...

  • Pelco ICIMI1000 - page 7

    Pelco Manual C1014M-B (10/97) 5 To define communication parameters for baud rate, type in the appropriate data and press “ENT” to save. T o define all the other communication param- eters, type the appropriate data for each parameter . (Refer to the section for Procedures for the V erifone Ruby Super System Cash Registers to setup com- municati ...

  • Pelco ICIMI1000 - page 8

    6 Pelco Manual C1014M-B (10/97) 3.2.2 Procedur es for the Gilbarco “G-Site” Cash Registers The following procedures are to be performed on the Gilbarco “G-Site” Cash Reg- isters: 1. Use the 8-pin modular adapter supplied with the ICIMI1000 when interfacing to this register . 2. Be sure the cables on the wiring kit are connected to the yello ...

  • Pelco ICIMI1000 - page 9

    Pelco Manual C1014M-B (10/97) 7 3.2.4 Procedures for the Suntr onics Station Minder 890, 960, and 2000 Cash Registers The following procedures are to be performed on the Suntronics Station Minder 890, 960, and 2000 Cash Registers 1. Be sure the cables on the wiring kit are connected to the yellow and black terminals only . 2. If the communication p ...

  • Pelco ICIMI1000 - page 10

    8 Pelco Manual C1014M-B (10/97) 5. V erifone uses the Epson Model TM930II as the standard printer on this regis- ter . If you are using the Epson Model TM950II printer , with 9-pin “D” style connector , you will need to use the Pelco ICIDRP interface cable. 6. Set the SW1 switch on the ICIMI1000 interface cable toward the male plug. Proceed to ...

  • Pelco ICIMI1000 - page 11

    Pelco Manual C1014M-B (10/97) 9 Figure 1. Wiring Diagram for One Cash Register or One A TM Machine Figure 2. Wiring Diagram for T wo Cash Registers or T wo A TM Machines STRAIGHT THROUGH PHONE CABLE TO ICI1000S INTER-CHECK ® UNIT WH BL YL BK RD GR WH BL YL BK RD GR ICIMI1000 INTERF ACE CABLE USER SUPPLIED 18 AWG SHIELDED WIRE IS RECOMMENTED WIRING ...

  • Pelco ICIMI1000 - page 12

    10 Pelco Manual C1014M-B (10/97) 4.0 INST ALLA TION FOR A TM MACHINES This section covers the installation of the ICIMI1000 interface cable with the Diebold, IBM, and NCR A TM machines. 4.1 INTER-CHECK ® PREP ARA TION 1. Check to see if Pelco supports the communication protocol your A TM is run- ning. A TMs having a different protocol may emulate ...

  • Pelco ICIMI1000 - page 13

    Pelco Manual C1014M-B (10/97) 11 Figure 3. A TM Machine Interface Cable Installation A TM MACHINE A TM NETWORK MODEM PLACE INTERF ACE CABLE HERE (ICIMI1000) ...

  • Pelco ICIMI1000 - page 14

    12 Pelco Manual C1014M-B (10/97) 4.3 INTER-CHECK ® PROGRAMMING 1. Select the appropriate communication protocol your A TM is using. Refer to your Inter-Check ® manual for a complete explanation on proper programming. 2. Set the A TM device addresses to “00”. 3. Make sure the Inter-Check ® unit receives data. The data seen on the monitor refl ...

  • Pelco ICIMI1000 - page 15

    Pelco Manual C1014M-B (10/97) 13 5.0 SPECIFICA TIONS GENERAL Environment: Indoor Operating Temperature: 32 ° to 120 ° F (0 ° to 49 ° C) Weight Unit Shipping 0.45 lbs (0.20 kg) 0.60 lbs (0.27 kg) Connectors: One (1) male 25 pin D-SUB connector One (1) female 25 pin D-SUB connector One (1) RJ-14 male connector Switching: Micro-mini SPDT slide swi ...

  • Pelco ICIMI1000 - page 16

    14 Pelco Manual C1014M-B (10/97) 6.0 WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1997, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, without charge, any merchandise proved defect ...

メーカー Pelco カテゴリー Stereo System

Pelco ICIMI1000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ICIMI1000の取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco ICIMI1000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco ICIMI1000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco ICIMI1000の取り付け説明書、サービスマニュアル、簡易説明書、またはPelco ICIMI1000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco ICIMI1000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco ICIMI1000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco ICIMI1000を使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco ICIMI1000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco ICIMI1000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco ICIMI1000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco ICIMI1000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco ICIMI1000デバイスの基本機能を使うにあたってのヒント。 Pelco ICIMI1000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco ICIMI1000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco ICIMI1000のメーカー/サービスへの連絡先に関する情報。

Pelco ICIMI1000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco ICIMI1000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco ICIMI1000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)