    OMEGA HH501BJ Digital Thermometer ...

  • Omega Engineering HH501BJ - page 2

    OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com Ser vicing Nor th America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com ome ...

  • Omega Engineering HH501BJ - page 3

    1 The symbol on the instrument indicates that the operator must refer to an explanation in this manual. WARNING To avoid electrical shock, do not use this instrument when working voltages at the measurement surface over 24V AC or DC. WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. CAUTION Repeated sharp fle ...

  • Omega Engineering HH501BJ - page 4

    SPECIFICATIONS ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable. Measurement Range: -210°C to 1200°C, -346°F to 1999°F Resolution: 0.1°C , 0.1°F (-59.9°C to 199.9°C ,-59.9°F to 199.9°F) 1°C , 1°F on other range Accuracy: Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F) ...

  • Omega Engineering HH501BJ - page 5

    3 ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Overload: "-OL" is display. Battery: Standard 9V battery. Battery Life: 100 hours typical. Auto pow ...

  • Omega Engineering HH501BJ - page 6

    OPERATING INSTRUCTIONS Power Switch The key turns the thermometer on or off. In the MIN MAX record mode can not power off, must leave MIN MAX record mode then power off. °C °F Selecting the Temperature Scale Readings is displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the tempera ...

  • Omega Engineering HH501BJ - page 7

    MIN MAX record Mode Press MIN MAX key to enter the MIN MAX Recording mode, (displays the Maximum reading, Minimum reading, "MAX-MIN" reading and Average reading stored in record mode). In the this mode the automatic power-off feature is disabled and key, °C °F key, REL key, SET key, Hi/Lo Limits key, T1 T2 T1-T2 key are disabled.The bee ...

  • Omega Engineering HH501BJ - page 8

    REL Relative mode (only Main display) Pressing REL key to enter the Relative mode, zero the display, and store the displayed Reading as a reference value and annunciator REL is displayed. Press REL key again to exit the relative mode. The relative value can also be entered by the user. (See "SET mode" later in this manual.) When the desir ...

  • Omega Engineering HH501BJ - page 9

    7 12 (Press ENTER key can escape Lo Limit value set mode), _ = = =.= is displayed (the ".=" is displayed when you set up the fourth number), Lo Limit value is entered via overlay numbers, when you want to get negative values push (- 0) key for end of numbers, then press overlay ENTER key, stored the Lo Limit value and exit set mode. 3. In ...

  • Omega Engineering HH501BJ - page 10

    8 OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. The " " appears on the LCD display when replacement is needed. To replace the battery, remove the two sc ...

  • Omega Engineering HH501BJ - page 11

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC . warrants this unit to be free of def ects in mater ials and w orkmanship for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month gr ace period to the nor mal one (1) year pr oduct warranty to cover handling and shipping time . This ensures that OMEGA's cu ...

  • Omega Engineering HH501BJ - page 12

    M-2818/0799 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE þ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies þ Wire: Thermocouple, RTD & Thermistor þ Calibrators & Ice Point References þ Recorders, Controllers & Process Monitors þ Infrared Pyromet ...

メーカー Omega Engineering カテゴリー Thermometer

Omega Engineering HH501BJのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HH501BJの取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering HH501BJの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering HH501BJの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering HH501BJの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering HH501BJのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering HH501BJの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering HH501BJデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering HH501BJを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering HH501BJユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering HH501BJの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering HH501BJの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering HH501BJに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering HH501BJデバイスの基本機能を使うにあたってのヒント。 Omega Engineering HH501BJのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering HH501BJに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering HH501BJのメーカー/サービスへの連絡先に関する情報。

Omega Engineering HH501BJについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering HH501BJの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering HH501BJで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)