    Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2006, Graco Inc. is r egistered to I. S. EN ISO 9001 311688D Instr uctions/P ar ts List Tr i t o n ® 3D150 Diaphra gm Pump Used to pump waterborne and sol vent-based paints and catalysts. P ar t No. 253704, Series B 3:1 Ratio Air-operated Doub le Diaphragm Pump, with BSPP Fittings P ar ...

  • Graco TRITON 3D150 - page 2

    2 311688D Contents W arning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 General Information . . . . . . . . . . . . . . . . . . . . . . 5 Tightening Thre aded F asteners Bef ore First Use 5 Mounting t he Pump . . . . . . . . . . . . . . . . . ...

  • Graco TRITON 3D150 - page 3

    Warnings 311688D 3 Wa r n i n g s The f ollowing w ar nings are f or the setup , use, g rounding, maintenance , and repair of this equipment. Th e exclama- tion point symbol ale r t s you to a gener al warning and the hazard symbol r efer s to procedure-specifi c r isk. Ref er bac k to these wa r nings. Additio nal, product- specific w ar nings ma ...

  • Graco TRITON 3D150 - page 4

    Warnings 4 311688D T O XIC FLUID HAZARD Hazardous fluid or t oxic fumes can cause serious injur y or death if splashed in the e y es or on the skin, inhaled, or s wallow ed. • Know the sp ecific hazards of the fl uid you are using. • Store hazardous fluid in an ap prov ed container . Dispose of hazardous fluid according to all local, state and ...

  • Graco TRITON 3D150 - page 5

    Installation 311688D 5 Installation General Inf ormation •F IG . 2 is only a guide f or installing system compo- nents and acce ssori es. It is not an actual system design. Contact y our Gr aco distribut or f or assis- tance in designi ng a system to suit y our particular needs . • Alwa ys use Genuin e Graco P ar ts and Accessories, av ailab le ...

  • Graco TRITON 3D150 - page 6

    Installation 6 311688D Mounting the Pump • F or ease of oper ation and service, mount the pump so the air inlet, flu id inlet, and fluid outlet po r ts are easily accessible. • Mount the pump in a well- v entilated area with suffi- cient clearance on all sides f or oper ator access and ser vicing. • The pump must be moun ted hor izontally as ...

  • Graco TRITON 3D150 - page 7

    Installation 311688D 7 Air Line 1. Install the air line accessories as sho wn in F IG . 2. Be sure the air line supplying the accessories is grounde d. a. The fluid pressur e can be controlled with either an air regu lator (F) t o control th e air into th e pump , or with a fluid regu lator (H) to control th e fluid out of the pum p . b . Install a ...

  • Graco TRITON 3D150 - page 8

    Installation 8 311688D F IG . 2. T ypical Inst allation R B C D E F K A L G S M W Key: A TRIT ON 3D150 Pump B Bleed-type master air valv e (required for pump) C Air supply line D Air line filter E Air line shutoff va lve F Pump air regulator G Gun air regul ator (used in spra y system only) H Fluid pressure regulator (used in spra y system only) J ...

  • Graco TRITON 3D150 - page 9

    Installation 311688D 9 Gr ounding Ground all of this equipment: • Pump: use a ground wire and clamp . See F IG . 3. Loosen the g rounding scre w (X). Insert one end of a 12 ga (1.5 mm 2 ) minimum gr ound wire (Y) under the clamp and tig hten the scre w securely . Connect the other end of t he wire to a true ear th ground. F or a ground wire and c ...

  • Graco TRITON 3D150 - page 10

    Operation 10 311688D Operation Pressure Relief Pr ocedure 1. Shut off the air to th e pump. 2. Open the dispensing v alv e, if used. 3. Open the fluid dr ain v alve to re liev e all fluid pres- sure, ha ving a container r eady to catch the drainage . Flushing the Pump Bef ore First Use The pump wa s tested in oil. If oil could contamin ate the flui ...

  • Graco TRITON 3D150 - page 11

    Maintenance 311688D 11 Maintenance Lubrication Flushing and Storage Flush the pump of ten enough to pre v ent the fluid y ou are pumping fr om curing, dr ying, or freezing in the pump and damaging it . Fo llow the Pressure Relief Procedure on page 10 bef ore storing it f or an y length of time . Use a compatib le flushing fluid. Tightening Threaded ...

  • Graco TRITON 3D150 - page 12

    Troubleshooti ng 12 311688D T r oubleshooting Relie ve t he pressure (page 10) befo re checking o r servicing the equipment. Chec k all possible prob lems and causes bef ore disassemb ling the pump . Prob lem Cause Solution Pump cycles at stall or f ails to hold pressure a t stall. W or n check v alve balls (26), seats (31), or ball guide s (32). R ...

  • Graco TRITON 3D150 - page 13

    Repair 311688D 13 Repair Prepare the Pump f or Repair 1. Flush the pump if possible , page 11. 2. Relie v e the pressure, pag e 10. 3. Disconnect the ai r and fluid hoses . 4. Remov e the pum p from its mounting and tak e it to the work benc h. General Repair Notes F ault Indications During operation, check f or indications o f worn or dam- aged pa ...

  • Graco TRITON 3D150 - page 14

    Repair 14 311688D Replace the Diaphragms Disassembl y 1. Prepare the pump fo r repair of the cylinder-side dia- phragm. a. Remov e the 6 scre ws (39) and fluid co ver (3 7) from the housing side of t he pump . b . Press on the e xposed diap hragm (9) to fully e xtend the cylinder-sid e diaphragm. c. Replace the housing-side co ver and tighten the 6 ...

  • Graco TRITON 3D150 - page 15

    Repair 311688D 15 F IG . 4 Replace the Dia phragms TI" T orque to 1 6 N•m (12 ft-lb). 1 29* †‡ ◆ 1 37 54 7 29* †‡ ◆ 29* †‡ ◆ 38 37 29* †‡ ◆ 39 Cylinder Side 9* Housing Side 9* 1 1 ...

  • Graco TRITON 3D150 - page 16

    Repair 16 311688D Repair the Air V alve Disassembl y 1. Prepare the pump fo r repair , page 13 . 2. Remov e the air valv e sheet metal co v er (36) and f elt dampener (34) . 3. Unscrew the cylin der screws (21). 4. Remov e the v alv e cov er (20) with the f lat gasket (19†). 5. Use two scr ewdriv ers to lift out the air v alv e plate (16†) and ...

  • Graco TRITON 3D150 - page 17

    Repair 311688D 17 F IG . 5. Repair the Air V alve ti2130B 12 Lubricate. T orque to 3.1 N•m (28 in-lb) Align arrow on housing with point on air valve plate . 1 2 3 13† ◆ 14 19† ◆ 20 21 34 36 44 10 11† ◆ 14 15† 17† ◆ 18† ◆ 16† 14 12 13† ◆ 11† ◆ 1 1 1 1 1 1 3 2 55 ...

  • Graco TRITON 3D150 - page 18

    Repair 18 311688D Repair the Shaft and Bearings Disassembl y 1. Remov e the diaphragms. See page 13. 2. Disassemb le the air v alve . See page 16. 3. Remove the housing (54). • Slee ve clamp (6) is visible inside th e air valv e cavity . Spread the sleev e clamp (6) with p liers DIN 5254A, nomin al size 19, and at the same time, slide the shaft a ...

  • Graco TRITON 3D150 - page 19

    Repair 311688D 19 F IG . 6. Repair the Shaft Lubricate. T orque to 1 2 ft-lb (16 N•m) Align arrow on housing with point on air valv e plate. T orque to 2 8 in-lb (3.1 N•m) 1 2 3 4 4 2 3 20 13 † ◆ 14 12 † ◆ 11 10 † ◆ 11 1 †‡ ◆ 29 *9 37 39 34 38 37 *9 54 ◆✘ 7 ◆ 29* †‡ ◆ * †‡ ◆ 29 † ◆ 19 †16 18 † ◆ 17 ...

  • Graco TRITON 3D150 - page 20

    Repair 20 311688D Replace the Ball Chec k V alves Disassembl y 1. Remo ve fluid cov ers (see page 13) . Do not remov e housing (5 4). 2. Remov e the inlet and outlet ball checks (2 6-32). Note that the orientation of the inlet check par ts is diff erent than the outlet check pa r ts. (Se e F IG . 7.) 3. Replace all parts provided in Kit 245067. Rea ...

  • Graco TRITON 3D150 - page 21

    Repair 311688D 21 F IG . 7. Replace the Ball Check V alves ti2128B T orque to 12 ft-lb (16 N •m) Align 1 2 1 2 Inlet Ball Checks Outlet Ball Checks 29 ‡ ‡32 ‡26 ‡28 ‡29 1 32 ‡ 26 ‡ 31 ‡ 30 ‡ ✖ 27 ‡26 ‡32 ‡28 ‡29 30 ‡ ✖ 31 ‡ 26 ‡ 32 ‡ 29 ‡ 1 ...

  • Graco TRITON 3D150 - page 22

    Parts 22 311688D Pa r t s P art No. 253704, Series B P art No. 253705, Series B 1 ★ 32 ‡ 26 ‡ 31 ‡ 5 *9 23 33 22 12 10 15 † 44 34 † ◆ 19 † 16 † ◆ 18 † ◆ 17 20 *9 ◆❖ 2 4 ‡ 27 14 ‡ 26 35 ‡ 28 ‡ 32 * †‡ ◆ 29 † ◆ 11 † ◆ 13 24 40 39 54 7 ◆ 6 29* †‡ ◆ 37 38 37 36 21 30 ‡ ✖ 41 25 ♦ 8 55 ti213 ...

  • Graco TRITON 3D150 - page 23

    Parts 311688D 23 P art No. 253704 BSPP , Series B P art No. 253705 NPT , Series B ★ Included in Diaphra gm Housing Repair Kit. Order Kit 261665 f or 253704 pum ps and 261666 f or 253705 pumps . ◆ Included in Shaft Repair Kit 233841. ❖ Included in Bearing Repair Kit . Order Kit 15J647. * Included in Diaphragm Repair Kit 246011. † Included in ...

  • Graco TRITON 3D150 - page 24

    Technical Data 24 311688D T ec hnical Data Sound Pressure Le vels in dB(A) at 50 cpm (measured at 1 me ter from unit) Category Data Maximum flu id working pressure 300 psi (2.1 MP a, 21 bar) Maximum air in put press ure 100 psi (0.7 MP a, 7 bar) Ratio 3:1 Maximum permissible str oke frequency in cycles/ min 20 V olume per cycle (double stroke) 5 oz ...

  • Graco TRITON 3D150 - page 25

    Performance Chart 311688D 25 P erformance Chart T riton perf ormance test, 40, 70, 100 psi (.27, . 48, .69 MP a; 2.7, 4.8, 6. 9 bar) Cycles per minute Outlet Flow in gallons per minute Outlet Pressure in PSI Air Flow in SCFM 40 psi 70 psi 100 psi 40 psi (.2 7 MPa, 2. 7 bar) 70 psi (.48 MP a, 4.8 bar ) 100 psi (.69 MP a, 6.9 bar) ...

  • Graco TRITON 3D150 - page 26

    Dimensions 26 311688D Dimensions 234 mm 184 mm (7.2 in.) 104 mm (4.1 in.) (9.2 in.) Fluid Inlet; 253705 3/4 npt 253704 M26x1.5 Fluid Outlet; 253705 3/8 npt 253704 3/8 BSPP 9 mm (0.35 in.) 102 mm (4.0 in.) 66 mm (2.6 in.) diameter mounting holes Air Inlet 253705 1/4 npt 253704 3/8 BSP P TI2133A 1 TI2133A 2 ...

  • Graco TRITON 3D150 - page 27

    Dimensions 311688D 27 ...

  • Graco TRITON 3D150 - page 28

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 311688 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 14 ...

メーカー Graco カテゴリー Heat Pump

Graco TRITON 3D150のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TRITON 3D150の取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco TRITON 3D150の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco TRITON 3D150の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco TRITON 3D150の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco TRITON 3D150のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco TRITON 3D150の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco TRITON 3D150デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco TRITON 3D150を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco TRITON 3D150ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco TRITON 3D150の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco TRITON 3D150の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco TRITON 3D150に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco TRITON 3D150デバイスの基本機能を使うにあたってのヒント。 Graco TRITON 3D150のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco TRITON 3D150に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco TRITON 3D150のメーカー/サービスへの連絡先に関する情報。

Graco TRITON 3D150についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco TRITON 3D150の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco TRITON 3D150で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)