    1 FrameSaver R SL V 9128 Quick Reference Document Number 9128-A2-GL10-40 May 2000 Product Documentation on the W orld Wide W eb We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain competitive price ...

  • Paradyne Paradyne FrameSaver - page 2

    2 00-16722a Menu Hierar ch y Status System and T est Status LMI Reported DLCIs PVC Connection Status Timeslot Assignment Status DBM Interface Status IP Routing T able Perf ormance Statistics T rap Event Log Display LEDs and Control Leads Identity Identity • System • NAM • DBM LMI Reported DLCIs • DLCI • Status • CIR (bps) PVC Connection ...

  • Paradyne Paradyne FrameSaver - page 3

    3 MAIN MENU Status T est Configuration Auto-Configur ation Control Easy Install Auto-Configuration • Fr ame Relay Discov ery Mode • Automatic Circuit Remov al • Automatic Backup Configuration 00-16728b MAIN MENU Status T est Configuration Auto-Configuration Control Easy Install System Information • Device Name • System Name, Location, Con ...

  • Paradyne Paradyne FrameSaver - page 4

    4 Configuration Option Summaries This section summarizes the configuration options accessed when you select Configuration from the Main Menu. H System H Physical (Network, Data Port, and ISDN) H ISDN (Link Profiles) H DSX-1 H T ime Slot Assignment — Frame Relay Network Assignments — DSX-1 to Network Assignments — Sync Data Port Assignments H ...

  • Paradyne Paradyne FrameSaver - page 5

    5 Frame Relay and LMI Select Frame Relay and LMI to configure the general frame relay options for the system. Frame Relay and LMI Configuration Option Settings Default in [ Bold ] LMI Behavior [ Independent ], Port-1_Follows_Net1-FR1, Port-2_Follows_Net1-FR1, All_Ports_Follow_Net1-FR1 Net1-FR1_Follows_Port-1, Net1-FR1_Follows_Port-2, Port-1_Codepen ...

  • Paradyne Paradyne FrameSaver - page 6

    6 General Select General to configure a timeout period and duration for user-initiated loopbacks and pattern tests, a primary and secondary clock source for the system, and a system alarm relay . General Configuration Option Settings Default in [ Bold ] T est T imeout [ Enable ], Disable T est Duration (min) 1 – 120 [ 10 ] Primary Clock Source [ ...

  • Paradyne Paradyne FrameSaver - page 7

    7 Data Ports Select Data Ports, then Physical to configure physical characteristics for the port connected to the DTE. Data Ports Configuration Option Settings Default in [ Bold ] Port Status [ Enable ], Disable Port Use (Port-2 only) [ Frame Relay ], Synchronous Data For Port-1 or when Port Use is set to Frame Relay on Port-2: Max Port Rate (Kbps) ...

  • Paradyne Paradyne FrameSaver - page 8

    8 ISDN Select ISDN, then Physical to configure physical characteristics for the ISDN interface if an ISDN DBM is installed. The following table shows the configuration options for an ISDN BRI DBM. ISDN BRI Configuration Option Settings Default in [ Bold ] Interface Status Enable, [ Disable ] Originate or Answer [ Originate ], Answer Service Profile ...

  • Paradyne Paradyne FrameSaver - page 9

    9 ISDN Link Profiles Select ISDN, then Link Profiles to configure the ISDN Link Profiles. Link Profiles Configuration Option Settings Default in [ Bold ] Link Name ASCII text entry , [ HQ_Site ] Link Status Auto, [ Disable ] Outbound Phone Number 0 – 9, * , # , <space>, _ , – , ), or ( Inbound Calling ID 1 or 2 0 – 9 Maximum Link Rate ( ...

  • Paradyne Paradyne FrameSaver - page 10

    10 Time Slot Assignment Select T ime Slot Assignment to make cross-connection assignments. Select Frame Relay Network Assignments to assign DS0s on the T1 network interface(s) for frame relay links. Frame Relay-to-Network Interface Time Slot Assignment Network Channel Settings Default in [ Bold ] T ime Slot Discovery [ Enable ], Disable N0 1 – N2 ...

  • Paradyne Paradyne FrameSaver - page 11

    11 Frame Relay Select Frame Relay to configure the Frame Relay characteristics of the following interfaces: H Network H Data Ports Frame Relay Configuration Option Settings Default in [ Bold ] LMI Protocol lnitialize_From_Net1FR1, Initialize_From_Interface, Auto_On_LMI_Fail, Standard, Annex-A, Annex-D [ lnitialize_From_Interface ] for a data port l ...

  • Paradyne Paradyne FrameSaver - page 12

    12 DLCI Records Select DLCI Records to manually configure DLCI records for each interface. The Auto-Configuration feature provides automatic configuration of DLCI records. Select DLCI Records to configure the DLCI Records for the following interfaces: H Network H Data Port H ISDN The Auto-Configuration feature provides automatic DLCI record configu ...

  • Paradyne Paradyne FrameSaver - page 13

    13 PVC Connections Select PVC Connections to manually configure the logical connections between the selected interface and the data ports. The Auto-Configuration feature provides automatic configuration of PVC connections. PVC Connections Configuration Option Settings Default in [ Bold ] Source Link Port- n , ISDN Link Name , Net1-FR1 Source DLCI 1 ...

  • Paradyne Paradyne FrameSaver - page 14

    14 Node IP Select Node IP to configure support of the IP communication network. Node IP Configuration Option Settings Default in [ Bold ] Node IP Address 001.000.000.000 – 223.255.255.255, [ Clear ] Node Subnet Mask [ 000.000.000.000 ] – 255.255.255.255, Clear Default IP Destination [ None ], Modem, COM, PVCname TS Access Management Link [ None ...

  • Paradyne Paradyne FrameSaver - page 15

    15 General SNMP Management Select General SNMP Management to configure the FrameSaver unit so it can be managed as an SNMP agent. General SNMP Management Configuration Option Settings Default in [ Bold ] SNMP Management [ Enable ], Disable Community Name 1 A SC II text entry , [ Public ], Clear Name 1 Access Read, [ Read/W rite ] Community Name 2 A ...

  • Paradyne Paradyne FrameSaver - page 16

    16 SNMP NMS Security Select SNMP NMS Security to configure access to the unit. SNMP NMS Security Configuration Option Settings Default in [ Bold ] NMS IP V alidation Enable, [ Disable ] Number of Managers [ 1 ] – 10 NMS n IP Address 001.000.000.000 – 223.255.255.255, [ Clear ] Access T ype [ Read ], Read/Write SNMP T raps Select SNMP T raps to ...

  • Paradyne Paradyne FrameSaver - page 17

    17 Communication Port Select Communication Port to configure the FrameSaver unit ’ s COM port. Communication Port Configuration Option Settings Default in [ Bold ] Port Use [ T erminal ], Net Link When Port Use is set to T erminal: Data Rate (Kbps) 9.6, 14.4, [ 19.2 ], 28.8, 38.4, 57.6, 1 15.2 Character Length 7, [ 8 ] Parity [ None ], Even, Odd ...

  • Paradyne Paradyne FrameSaver - page 18

    18 Modem Port Select Modem Port to configure the FrameSaver unit ’ s Modem port. Modem Port Configuration Option Settings Default in [ Bold ] Port Use [ T erminal ], Net Link When Port Use is set to T erminal: Dial-In Access [ Enable ], Disable Login Required Enable, [ Disable ] Port Access Level [ Level-1 ], Level-2, Level-3 Inactivity T imeout ...

  • Paradyne Paradyne FrameSaver - page 19

    19 W arranty , Sales, Service, and T raining Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty , sales, service, repair , installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one ...

メーカー Paradyne カテゴリー Network Hardware

Paradyne Paradyne FrameSaverのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FrameSaverの取扱説明書
- Paradyneの製品カード
- パンフレット
- またはParadyne Paradyne FrameSaverの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Paradyne Paradyne FrameSaverの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Paradyne Paradyne FrameSaverの取り付け説明書、サービスマニュアル、簡易説明書、またはParadyne Paradyne FrameSaverのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Paradyne Paradyne FrameSaverの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Paradyne Paradyne FrameSaverデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがParadyne Paradyne FrameSaverを使用するのを助ける技術的文書のことです。説明書は通常、全てのParadyne Paradyne FrameSaverユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Paradyneの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Paradyne Paradyne FrameSaverの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははParadyne Paradyne FrameSaverの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Paradyne Paradyne FrameSaverに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Paradyne Paradyne FrameSaverデバイスの基本機能を使うにあたってのヒント。 Paradyne Paradyne FrameSaverのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Paradyne Paradyne FrameSaverに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるParadyne Paradyne FrameSaverのメーカー/サービスへの連絡先に関する情報。

Paradyne Paradyne FrameSaverについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもParadyne Paradyne FrameSaverの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがParadyne Paradyne FrameSaverで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)