    FieldPoint™, National Inst ruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. Product and company names ment ioned herein are trade marks or trade names of thei r respective companies. 323179A-01 © 2001 National Ins truments Corp. All rights reserv ed. November 2001 OPERA TING INSTRUCTIONS FP-PS-4 FieldPoint Pow ...

  • National Instruments FP-PS-4 - page 2

    FP-PS-4 Operating Instructions 2 ni.com 1. Use a flat-bladed screwdr iv e r to unlock the DIN rail clip, as s h o w ni nF i g u r e1 . Figure 1. Unlocking the Rail Clip 2. Attach the lip on the rear of the FP-PS-4 onto t he top of a 35 mm DIN rail and press it do wn onto the DIN rail, as sho wn in Figure 2. Figure 2. Attaching the Module to a DIN R ...

  • National Instruments FP-PS-4 - page 3

    © National Instruments Corp. 3 FP-PS-4 Operating Instructions 3. Slide the FP-PS-4 to the desired position along the DIN rai l. For max imum cooling, lea v e a 25 mm (1.0 in.) space between the FP-PS-4 and other devices on your DIN rail. After it is in position, lock it to the DIN rail b y pushing the rail clip to the locked position, as sho wn in ...

  • National Instruments FP-PS-4 - page 4

    FP-PS-4 Operating Instructions 4 ni.com Mounting Y our FP-PS-4 on a Panel Follo w these steps to install the optional FieldPoint network panel mount accessory and mount the FP-PS-4 po wer supply module to a panel. Y ou can order the panel mount accessory , part number 777609-01, from National Instruments. 1. Use a flat-bladed scre wdri ver to unloc ...

  • National Instruments FP-PS-4 - page 5

    © National Instruments Corp. 5 FP-PS-4 Operating Instructions 4. Mount the FP-PS-4 to your panel with the panel mount accessory , as sho wn in Figure 5. The installation guide that comes with the panel mount accessory includes a template that you can use to drill pilot holes for mounting FieldPoint modules. For maximum cooling, lea ve a 25 mm (1.0 ...

  • National Instruments FP-PS-4 - page 6

    FP-PS-4 Operating Instructions 6 ni.com needs. Select one or a combination of the methods to po wer the signals of each of yo ur I/O modules: • The signals of the I/O module are po wered by an FP- PS-4 that is connected to only that I/O module. • The signals of the I/O module share an FP-PS-4 with a neighboring I/O module or network module. Thi ...

  • National Instruments FP-PS-4 - page 7

    © National Instruments Corp. 7 FP-PS-4 Operating Instructions Ensure that all the wiring is installed according to local codes and regulations b y qualif ied electrical personnel. Follo w these steps to connect the FP-PS-4 to your FieldPoint system. 1. Use a 16 to 26 A WG stranded wire to connect the FP-PS-4 to your FieldPoint network module or I/ ...

  • National Instruments FP-PS-4 - page 8

    FP-PS-4 Operating Instructions 8 ni.com 6. Connect the green or green/yellow conductor into the ground terminal. Caution When you install the conductors, make sure that the entire conductor is in the screw terminal and that there are no loose strands outside of the termi nal. Only install one wire in each terminal. Specifications The following spec ...

  • National Instruments FP-PS-4 - page 9

    © National Instruments Corp. 9 FP-PS-4 Operating Instructions Overload protection ....... ........... ........ Protected against short circuits and output ov erload Physical Indicator .......... ........ ......... ............ ..... Green DC PO W ER LED W eight .... ........... ......... ........... ......... ... 300 g (10.5 oz) Environmental Fiel ...

  • National Instruments FP-PS-4 - page 10

    FP-PS-4 Operating Instructions 10 ni.com regulatory compliance information. T o obtain the DoC for this product, cli ck Declaration of Conformity at ni.com/hardref.nsf/ . Mechanical Dimensions Figure 9 sho ws the mechanical dimensions of the FP-PS-4. Dimensions are giv en in millimeters [inch es]. Figure 9. Mechanical Dimensions 109.5 [4.31] 91.44 ...

  • National Instruments FP-PS-4 - page 11

    © National Instruments Corp. 11 FP-PS-4 Operating Instructions Where to Go for Support For more informatio n about setting up your FieldPoint system, refer to these National Instruments documents: • Y our FieldPoint network module user manual • Y our other FieldPoint I/O module operating instructions • Y our FieldPoint terminal base operatin ...

メーカー National Instruments カテゴリー Power Supply

National Instruments FP-PS-4のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FP-PS-4の取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments FP-PS-4の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments FP-PS-4の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments FP-PS-4の取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments FP-PS-4のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments FP-PS-4の製品を使用するにあたって最も人気のある説明書を閲覧できます。

National Instruments FP-PS-4デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments FP-PS-4を使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments FP-PS-4ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments FP-PS-4の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments FP-PS-4の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments FP-PS-4に関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments FP-PS-4デバイスの基本機能を使うにあたってのヒント。 National Instruments FP-PS-4のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments FP-PS-4に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments FP-PS-4のメーカー/サービスへの連絡先に関する情報。

National Instruments FP-PS-4についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments FP-PS-4の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments FP-PS-4で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)