    VP AP™ A uto 25 VP AP™ S T VP AP™ S Positive Airw A y Pressure device User Guide English ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 2

    English VP AP™ A uto 25 VP AP™ S T VP AP™ S POSITIVE AI RWA Y PRES SURE DEVICE User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park Abingdon Oxfordshi ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 3

    Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contraindications 1 Adv erse Ef f ects 1 The VP AP S ystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Masks 2 Humidifier 2 ResScan Data Card 2 Supplemental Oxygen 3 Using the VP AP Auto 25 ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 4

    1 Introduction English Introduction The VPAP TM Auto 25 , VPAP TM ST and the VPAP TM S are i ndicated for the treatment of obstructive sleep ap nea (OSA) in patients weighing more than 66 lb (30 kg). They are intended for home and hospit al use. Contraindications Positive airwa y pressure therapy may be contraindicated in some patien ts with the fo ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 5

    2 Masks The following Re sMed mask systems are re commended for use with these devices: For information on using masks, see your mask manual. For the latest avai lable masks, see www.resmed.com. Humidifier If you are experie ncing dryness of the nose, throat or mouth, the H4i heated humidifier is recommend ed for use with these VPAP devices. ! WARN ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 6

    3 Using the VP AP Auto 25, VPAP ST & VP AP S English Supplemental Oxygen The VPAP Auto 25, VPAP ST and VPAP S are designed to be compatible with the following levels of supplemental oxygen usage: • Up to 4 L/mi n in V Auto mod e • Up to 1 5 L/min in CP AP , S, ST and T modes. At a fixed flow rate of supple mental oxygen flow, the inhaled ox ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 7

    4 ! CAUTION • Be careful not to place the device where it can be bumped or where someone is likely to trip over the powe r cord. • If you put the device on the floo r , mak e sure the area is free from dust and clear of bedding, clot hes or other objects that c ould bloc k the air inlet. Attaching a H4i Humidifier The H4i humidifier attaches to ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 8

    5 Using the VP AP Auto 25, VPAP ST & VP AP S English Using the Menus The VPAP Auto 25 , VPAP ST and VPAP S provide a set of functions whi ch are arranged in menus and submenus. Vi a the LCD screen, the menus and submenus allow you to view and change the settings for a particul ar function. To navigate and make selections with in the Patient Men ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 9

    6 How to Select the Mask Type Scroll to MASK and select . Press or until you see the setting you require. The fo llowing table shows the setting that should be se lected for each mask : How to change the EPR level (CPAP mode) Expiratory Pressure Reli ef (EPR) can be used to improve your comfort l evel when breathing out during treatment. If patient ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 10

    7 Using the VP AP Auto 25, VPAP ST & VP AP S English Starting Treatment 1 Make sure the power is on. The product name is displayed briefly on the LCD screen , then the standby (Ramp/ Settle) screen appears. The key and LCD backlights also turn on. 2 Fit your mask as d escribed in the mask user instructions. ! WARNING A mask should no t be used ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 11

    8 Using the Mask-Fitting feature The VPAP Auto 25, VPAP ST and VPAP S include a m ask-fitting feature to help you fit your mask properly. The mask-fitting fe ature deliv ers air pressure for a three- minute period, prior to starting treatment, for checking and adjusting you r mask fit to minimize leaks. To use the mask-fitting feature: 1 Fit your m ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 12

    9 Using the VP AP Auto 25, VPAP ST & VP AP S English Using the Data Card If your clinician need s to review your treatment, they will a sk you to use the Data Card to copy data from your VPAP device and return th e card to them. Copying Data onto a Data Card 1 Switch on your VPAP and wai t until you see the standby (Ramp/Settle) screen. 2 Hold ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 13

    10 Traveling with the VPAP Auto 25, VPAP ST & VPAP S International Use Your VPAP flow generator has an internal pow er adapter that enable s it to operate in other countries. It will operate on power supplies of 100–240V and 50–60Hz. No special adjustment i s necessary, but you wil l require an approved power co rd for that country. Use on ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 14

    11 Cleaning and Maintenance English Cleaning and Maintenance You should regularly carry out the cleaning and main tenance described in this section. Refer to your mask and humidifier manuals fo r detailed instru ctions regarding the care of those devices. Daily Disconnect the air tubing and hang it in a clean, dry pla ce until next use. Weekly 1 Re ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 15

    12 ! WARNING • Do not wash the air filt er . The air filter is not washable or reusab le. • The air filter cover protec ts the devi ce in the even t of accidental liquid spillage onto the devic e. Ensure the air filter and air filt er cover are fit ted at all times. Servicing This product should be inspe cted by an authorized Res Med service ce ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 16

    13 T roubleshooting English Troubleshooting If there is a p roblem, try the fol lowing suggestions. If the problem cannot be solved , contact your equipment supplier or Re sMed. Do not attempt to open the device. No display Insufficient air delivered fr om the VP AP device Device doe s not star t when y ou br eathe into th e mask Device does not st ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 17

    14 Displays er ror message: Check tube!! Key if done Displays er ror message: Exxxx Call Service (wher e xxxx defines an err or) Displays er ror message: HIGH LEAK!!! Adjust Mask The follow ing message is display ed on the LCD aft er you try to update set tings or copy data to the D ata Card : Card Error Remove Card The follow ing message is displa ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 18

    15 T echnical Specifications English Technical Specifications Note: The manufact urer res er ves the right to change these specific ations without notice . Symbols Which Appear On The Device At tention, consult accompany ing document s; Drip proof; T ype CF equipment; Dangerous voltage; Class II equipment; Start/Stop; Manufacturer . Operating press ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 19

    16 General Warnings and Cautions ! Warnings • Advice contained in this manual should not supersede instructions given b y the prescribing physician. • A patient should not connect a device to the data com municati on port unless instructed to do so by their health care pro v ider or phys ician. Only ResMed products are designed to be connected ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 20

    17 General W arnings and Cautions English Guidance and Manufactur er’ s Declaration – Electromagnetic Emissi ons and Immunity Guidance and manufact urer’ s declaration – electromagnetic emissions The V P AP Aut o 25 , VPA P ST and VP AP S device s are intended for use in the electr omagnetic en vironment spe cified belo w . The customer or ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 21

    18 Guidance and manu f acturer’ s de claration – electromagnetic immunity The VP AP device is intended f or use in the electromagn etic envi ronment specif ied belo w . T he customer or th e user of th e VP AP devic e should assur e that the de vice is used in suc h an en vironment. Immunity test I E C 6 0 6 01- 1- 2 te s t level Compliance lev ...

  • ResMed VPAP Auto 25 VPAP ST VPAP S - page 22

    19 Limited W arranty English Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period speci fied below from the d ate of purchase by the initial co nsumer. Th is wa rranty is not transf erable. Note: Some model s are not av ailable in all re gions. If the product fails under con ...

メーカー ResMed カテゴリー Sleep Apnea Machine

ResMed VPAP Auto 25 VPAP ST VPAP Sのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VPAP Auto 25 VPAP ST VPAP Sの取扱説明書
- ResMedの製品カード
- パンフレット
- またはResMed VPAP Auto 25 VPAP ST VPAP Sの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ResMed VPAP Auto 25 VPAP ST VPAP Sの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ResMed VPAP Auto 25 VPAP ST VPAP Sの取り付け説明書、サービスマニュアル、簡易説明書、またはResMed VPAP Auto 25 VPAP ST VPAP Sのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ResMed VPAP Auto 25 VPAP ST VPAP Sの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ResMed VPAP Auto 25 VPAP ST VPAP Sデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがResMed VPAP Auto 25 VPAP ST VPAP Sを使用するのを助ける技術的文書のことです。説明書は通常、全てのResMed VPAP Auto 25 VPAP ST VPAP Sユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ResMedの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ResMed VPAP Auto 25 VPAP ST VPAP Sの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははResMed VPAP Auto 25 VPAP ST VPAP Sの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ResMed VPAP Auto 25 VPAP ST VPAP Sに関してこのドキュメントで見つけることができる全てのヒントの目次
3. ResMed VPAP Auto 25 VPAP ST VPAP Sデバイスの基本機能を使うにあたってのヒント。 ResMed VPAP Auto 25 VPAP ST VPAP Sのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ResMed VPAP Auto 25 VPAP ST VPAP Sに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるResMed VPAP Auto 25 VPAP ST VPAP Sのメーカー/サービスへの連絡先に関する情報。

ResMed VPAP Auto 25 VPAP ST VPAP Sについてご質問がありますか?