  • Parker Hannifin acr-motion max api users guide - page 1

    API Users Guide Getting Started - 1 ACR -MotionMa x API User s Guide ...

  • Parker Hannifin acr-motion max api users guide - page 2

    2 - Getting Starte d API Users Guide User I nformatio n   ACR Series products are used to co ntrol e lectrical an d mec hanical components of m otion control s ystems . You should tes t your m otion s ystem for saf ety under all po tential con ditions. Fai lure to do s o can res ult in dam age to equipm ent and/or s erious i ...

  • Parker Hannifin acr-motion max api users guide - page 3

    API Users Guide Getting Started - 3 Conte nts Getting Started ..................................................................................................................................... 5 Introduction ........................................................................................................................................... ...

  • Parker Hannifin acr-motion max api users guide - page 4

    4 - Getting Starte d API Users Guide AX_JogStop ............................................................................................................................................................ 12 AX_Home Axis ................................................................................................................................. ...

  • Parker Hannifin acr-motion max api users guide - page 5

    API Users Guide Getting Started - 5 Getting Starte d Introdu ction This Guide gi ve basic i nstructions o n the functionali ty and imp lementation o f the Motio nCore.DL L API. Only experience d evelopers o f motion contro l soft ware should attempt to use t his API. A working k nowledge of t he Parker/Acro loop Acro Basic langua ge is also req uir ...

  • Parker Hannifin acr-motion max api users guide - page 6

    6 - API Comma nd Groups API Users Guide API Com mand Group s Command Gro ups DLL Initialization AX_Initialize Control Start DL L … this must be the fir st call to the D LL AX_IsCard Present Checks for Servo Con troller Presence Parameters AX_UpdateP ara ms Force DL L to Reload All P arameter s from Para meters.Cfg F ile AX_Downloa dPar ameters2Ca ...

  • Parker Hannifin acr-motion max api users guide - page 7

    API Users Guide API Comman d Groups - 7 Jogging & Homing AX_JogMi nus JOG SELECT ED AXIS MINUS DIRE CTI ON AX_JogPlus J OG SELECTE D AXIS P LUS DIRECT ION AX_JogMi nusFast JOG SELECTED A XIS MINUS D IRECT ION at Fast Rate AX_JogPlus Fast JOG SELECT ED AXIS P LUS DIRE CTION a t Fast Rate AX_JogStop STOP ALL JOGGING AX_Home Axis HOME T HE SELECT ...

  • Parker Hannifin acr-motion max api users guide - page 8

    8 - API Comma nd Descriptions API Users Guide API Com mand De scriptions (DLL Initialization) AX_InitializeControl Description Sends Ha ndle (. hwnd) of t he Applicatio ns Main For m to the D LL to spa wn its threads. Returns (Integer) 1 on Success, 0 on Failure Arguments (Lon g) handle o f the Applicatio ns Main Fo rm VB Exa mple: Privat e Sub fr ...

  • Parker Hannifin acr-motion max api users guide - page 9

    API Users Guide API Command De scriptions - 9 (Parameter Functions) AX_UpdatePa rams Description For ce DLL to Relo ad All Par ameters fro m Para meters.Cfg File Returns (Integer) 1 on Success, 0 on Failure Arguments No ne VB Exa mple: Privat e Sub UpdateP ara m sBtn_Clic k () ‘ Force DLL to Reload All Para meters fro m Parameters.Cfg File Call A ...

  • Parker Hannifin acr-motion max api users guide - page 10

    10 - API Comm and Descriptions API Users Guide AbsReadout ( 0).Captio n = Format((( EncoderArra y(0) * Val(R esolution0) ) - Wor kOffsetsArra y(0)), " 00.0000") AbsReadout(1 ).Caption = Format(((E ncoderArra y(1) * Val(R esolution1)) - WorkO ffsetsArra y(1)), "0 0.0000") AbsReadout(2 ).Caption = Format(((E ncoderArra y(2) * Val( ...

  • Parker Hannifin acr-motion max api users guide - page 11

    API Users Guide API Command Des criptions - 11 AX_BitOff Description T urns off any bit e xcept the I nputs Returns (Integer) 1 on Success, 0 on Failure Arguments Glo bal BitNu m as Integer VB Exa mple: Call Ax_B itOff ( 512) ‘Clear Kill Moves t o Card Declarat ion: Public Declare Functio n AX_BitO ff Lib _ "Mo tionCore.DLL" (B yVal Bit ...

  • Parker Hannifin acr-motion max api users guide - page 12

    12 - API Comm and Descriptions API Users Guide AX_GetMas terFlags Description Get all 32 M ASTERFLAGS bit s from DL L Returns (Integer) 1 on Succes s, 0 on Fail ure Arguments Glo bal MasterFlag s As Strin g: MasterFla gs = Space (33) VB Exa mple: Ret = AX_Ge tMasterFlag s (MasterFla gs) Declarat ion: Public Declare Functio n AX_GetMa sterFlags Lib ...

  • Parker Hannifin acr-motion max api users guide - page 13

    API Users Guide API Command Des criptions - 13 Returns (Integer) 1 on Succes s, 0 on Fail ure Arguments Glo bal CurrentA xis as Integer 0 = Axis0 1=Axis1 2=Axis2 VB Exa mple: ‘ To Jo g an Axis Place Code in “ M ouseD own ” Event Privat e Sub Jog PB_MouseDow n (But ton As Integer, Shift As Integ er, X As Si ngle, Y As Single) Ret = AX_J ogMinu ...

  • Parker Hannifin acr-motion max api users guide - page 14

    14 - API Comm and Descriptions API Users Guide Place VB Code in a button 'Home X Axis Ret = AX_Ho meAxis (0) HomingActive LblTXT.Cap tion = " Homing ... " & Axis0Letter Sleep (500) WaitForX : DoEvents If Mid (Contro lSignals, 2, 1 ) = 1 O r Mid (ControlSig nals, 3, 1) = 1 T hen Goto HomeErr 'if Estop exit 'If X not ho m ...

  • Parker Hannifin acr-motion max api users guide - page 15

    API Users Guide API Command Des criptions - 15 Declarat ion : Public Dec lare Function AX_StartM DI Lib " MotionCore. DLL" _ () As Integer AX_StopMDI Description End MDI Mo de Signal to D LL Returns (Integer) 1 on Succes s, 0 on Fail ure Arguments No ne VB Exa mple: Call AX_Stop MDI: Sleep (100 ) Declarat ion: Public Declare Functio n AX_ ...

  • Parker Hannifin acr-motion max api users guide - page 16

    16 - API Comm and Descriptions API Users Guide Public Dec lare Function AX_SetRov Lib "M otionCore.DL L" _ (ByVal RovVal a s Double) As Integer Public Dec lare Function AX_SetSov Lib "M otionCore.D LL" _ (ByVal SovVal as Do uble) As Integer (Graphics Functions) AX_InitializeG PH Description Initialize Graphic s Engine and give i ...

  • Parker Hannifin acr-motion max api users guide - page 17

    API Users Guide API Command Des criptions - 17 AX_ SetG raphics Description P ass Screen Coor dinates (in P ixels) of the Zoo mBox to the API for Zoo m operations Returns (Integer) 1 on Succes s, 0 on Fail ure Arguments: ByVal iGraphicsOn As Integer VB Exa mple: 'Turn Graphic s On Call AX_SetGra phics (1 ) 'Turn Graphic s Off Call AX_SetG ...

  • Parker Hannifin acr-motion max api users guide - page 18

    18 - API Comm and Descriptions API Users Guide (Cycle Functions) AX_CycleSta rt Description Cause DLL to Start running t he current Loaded G code file from the Specified Line Returns (Integer) 1 on Succes s, 0 on Fail ure Arguments: Glob al Linenum a s Long VB Exa mple: Call AX_Cycle Start (0 ) ‘ Start P rogram fro m first Line Declarat ion: Publ ...

  • Parker Hannifin acr-motion max api users guide - page 19

    API Users Guide API Command Des criptions - 19 Reset Description Settin g these bits i n an Optio n Button will effect a feed hold to the Card This is not a n API functio n but how we effect a Reset Returns Nothi ng Arguments: None VB Exa mple: Private Sub Rese tBtn_Cl ick () Call AX_BitOn (130) 'set reset bit …Stop Program and reset to line ...

  • Parker Hannifin acr-motion max api users guide - page 20

    20 - I/O Map API Users Guide I/O Map A crol oop I/O Layout Control Signals These bits [ 128-255 ] used by the DLL for co mmunicatio n with the VB and AcroB asic. The M otionCore.D LL depends on the se bits so do n’t use the m in yo ur Vb progr ams for an y other purpo se than as defined belo w. If you need to use some bits for your pr ogram logic ...

  • Parker Hannifin acr-motion max api users guide - page 21

    API Users Guide I/O Map - 21 152 T Strob e Set By ACR-MOT IONMAX wh en a T Code has been Sent to b e serviced b y AcroBasic 153 Tool Change Active Set by ACR -MOTIO NMAX DLL to Signal M6 Sub needs to do a chan ge 154 Tool Change D one Set B y AcroBasic in M6 Code to signal a tool change has fini shed ok 155 Z @ T change P osition Set By AcroB asic ...

  • Parker Hannifin acr-motion max api users guide - page 22

    22 - I/O Map API Users Guide 199 Reserved for future use 200 Reserved for future use 202 Progra m Running Set by ACR -MOTIO NMAX signal s that a G Co de pro gram is running I nCycle 203 Progra m Modified Set by ACR -MOTIO NMAX when the c urrent pr ogram has b een altere d 204 to 212 Reserved for future use (Do n’t Use) 213 Digital FOV B it0 4 bit ...

メーカー Parker Hannifin カテゴリー Home Theater Server

Parker Hannifin acr-motion max api users guideのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- acr-motion max api users guideの取扱説明書
- Parker Hannifinの製品カード
- パンフレット
- またはParker Hannifin acr-motion max api users guideの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Parker Hannifin acr-motion max api users guideの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Parker Hannifin acr-motion max api users guideの取り付け説明書、サービスマニュアル、簡易説明書、またはParker Hannifin acr-motion max api users guideのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Parker Hannifin acr-motion max api users guideの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Parker Hannifin acr-motion max api users guideデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがParker Hannifin acr-motion max api users guideを使用するのを助ける技術的文書のことです。説明書は通常、全てのParker Hannifin acr-motion max api users guideユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Parker Hannifinの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Parker Hannifin acr-motion max api users guideの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははParker Hannifin acr-motion max api users guideの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Parker Hannifin acr-motion max api users guideに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Parker Hannifin acr-motion max api users guideデバイスの基本機能を使うにあたってのヒント。 Parker Hannifin acr-motion max api users guideのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Parker Hannifin acr-motion max api users guideに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるParker Hannifin acr-motion max api users guideのメーカー/サービスへの連絡先に関する情報。

Parker Hannifin acr-motion max api users guideについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもParker Hannifin acr-motion max api users guideの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがParker Hannifin acr-motion max api users guideで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。