Linear AE-100の取扱説明書

24ページ 1.1 mb
ダウンロード

ページに移動 of 24

Summary
  • Linear AE-100 - page 1

    (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com AE-100 Commercial T elephone Entr y System PRINTER’S INSTRUCTIONS: INSTR,AE-100,F ACILITY MANA GER - LINEAR P/N: 227354 B - INK: BLACK - MA TERIAL: 20 LB . MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALB UM-FOLD - ...

  • Linear AE-100 - page 2

    2 Contents Introduction The Model AE-100 Commercial T elephone Entry System is designed for use as an access control de vice for small apar tments or gated communities with up to 125 residents. The system can be used in a lobby or outside . Surf ace, recessed, and pedestal mounting options are suppor ted. The system utiliz es hands-free, full duple ...

  • Linear AE-100 - page 3

    3 Sys tem F eatur es DI S PLAY CABINET LOCK OPTIONAL PO S TAL LOCK S PEAKER KEYPAD LIGHTING KEYPAD MICROPHONE OPTIONAL CCTV CAMERA TTY JACK Your access control installation company has set this Master Password for this installation: ____ ____ ____ ____ ____ ____ Use this password to enter programming mode. ...

  • Linear AE-100 - page 4

    4 Access to P r ogramming T o make it easy f or installers familiar with Linear’ s and other manufacturer’ s access control systems, two methods of prog ramming are av ailable. Programming P osition Numbers (or Function Codes) that match other equipment help the installer to make quic k programming changes with ke ystrokes they’v e used bef o ...

  • Linear AE-100 - page 5

    5 P r ogramming Over the T elephone Most system commands can be programmed using a T ouchT one™ telephone. The telephone’ s keypad will act similar to the AE-100’ s keypad. Both programming methods can be used o ver the telephone. Connecting with a T elephone 1. Place a call to the telephone number of the line that the AE-100 is connected to ...

  • Linear AE-100 - page 6

    6 P r ogramming Refer ence & F actor y Defaults ST AND ARD PROGRAMMING POSITION NUMBER AL TERNA TE FUNCTION CODE NUMBER FUNCTION OF PROGRAMMING STEP F A CTOR Y DEF A UL T VA L U E 99 91 EXIT PROGRAM MODE SYSTEM OPTIONS 38 38 SYSTEM DISPLA Y LANGUA GE ENGLISH 51 72 KEYP AD LOCK OUT COUNT 3 TRIES 52 71 ACCESS RELA Y A CTIV A TION TIME 4 SECONDS 5 ...

  • Linear AE-100 - page 7

    7 Resident Data P r ogramming Up to 125 resident Names and T elephone Numbers can be set. Each resident entry is assigned a Director y Code . The Director y Code is the number visitors enter to hav e the system call the resident. Visitors can also contact a resident display ed by pressing the key . Use the programming w orksheet supplied to organiz ...

  • Linear AE-100 - page 8

    8 Stand-alone Entr y Code Pr ogramming A Stand-alone Entry Code is a number entered at the AE-100 ke ypad to request access. Up to 125 4-digit Stand-alone Entr y Codes can be set. ✦ NO TE: Each Stand-alone Entr y Code programmed reduces the possible n umber of Director y Entries by one. Use the programming w orksheet supplied to organize the Stan ...

  • Linear AE-100 - page 9

    9 Sys tem Options For most installations the f actor y settings for the system will be appropriate. T o customize the system, enter programming mode via telephone or ke ypad. Use the programming w orksheet supplied to log any system option changes prior to entering it into the system. For each of the f ollowing steps, enter the Master P assword and ...

  • Linear AE-100 - page 10

    10 Sys tem Options (Continued) W elcome Display T ext The AE-100 display will sho w a visitor a welcome message alternating with instructions on how to fi nd and call a resident. The welcome message can be customized to suit the installation. ✦ NO TE: This step cannot be perf or med remotely through the telephone. 1. Press ✦ NO TE: T o enter c ...

  • Linear AE-100 - page 11

    11 Sys tem Options (Continued) Maximum Visitor T alk Time Visitors will conv erse with residents ov er the telephone until the resident grants or denies access . If the resident responds to the visitor’ s request by pressing their telephone k ey , the system will hang up and release the telephone line. If for some reason the resident does not pre ...

  • Linear AE-100 - page 12

    12 Sys tem Utilit y Commands Sev eral utility commands are a vailable f or the system. Utility commands can be used to copy data to other units in a multi-unit installation , clear memory , and control the relays. For each of the f ollowing steps, enter the Master P assword and enter Programming Mode (if the unit is not already in that mode). Exit ...

  • Linear AE-100 - page 13

    13 Sys tem Utilit y Commands (Continued) Timed Access Relay Latch For servicing or testing, while in Programming Mode, the access rela y can be latched manually from the ke ypad for a period of hours. 1. Press 2. Enter the amount of time in hours (01-98) for the access rela y to latch. 3. Press Latch Access Relay For servicing or testing, while in ...

  • Linear AE-100 - page 14

    14 Alternate P r ogramming Section T o make it easy f or installers familiar with Linear’ s and other manufacturer’ s access control systems, two methods of prog ramming are av ailable. Function Codes that match other equipment help the installer to make quick progr amming changes with keystrok es they ha ve used bef ore. Alternate Programming ...

  • Linear AE-100 - page 15

    15 Alternate P r ogramming Refer ence Refer to the follo wing pages when programming using the Alternate Programming method. For each of the f ollowing steps, enter the Master P assword and enter Programming Mode (if the unit is not already in that mode). Exit Programming Mode when all progr amming is complete. FUNCTION CODE LOCAL PROGRAMMING TELEP ...

  • Linear AE-100 - page 16

    16 FUNCTION CODE LOCAL PROGRAMMING TELEPHONE PROGRAMMING 02 MODIFY AN EXISTING TENANT DIRECT OR Y ENTR Y Choose a tenant’ s Director y Code to modify (you must kno w the tenant’ s Director y Code to modify). Step 1 Enter Function Code 02, then press #. Step 2 Enter the new 2 or 3 digit Directory Code . Then the tenant’ s current Name is displ ...

  • Linear AE-100 - page 17

    17 FUNCTION CODE LOCAL PROGRAMMING TELEPHONE PROGRAMMING 05 MANU AL ACCESS RELA Y CONTROL This command can be used to latch the access relay indefi nitely or for a period of time, and to unlatch the access relay . Step 1 Enter Function Code 05, then press #. Step 2 Enter the number of hours from 01-98 to energize the access rela y , then press #. ...

  • Linear AE-100 - page 18

    18 FUNCTION CODE LOCAL PROGRAMMING TELEPHONE PROGRAMMING 31 ADD A ST AND-ALONE A CCESS CODE A Stand-alone Access Code is a number entered at the AE-100 keypad to request access . Up to 125 4-digit Stand-alone Access Codes can be set. NO TE: Each Stand-alone Access Code programmed reduces the possible number of Directory Entries by one. Step 1 Enter ...

  • Linear AE-100 - page 19

    19 FUNCTION CODE LOCAL PROGRAMMING TELEPHONE PROGRAMMING 70 MAXIMUM VISIT OR T ALK TIME If for some reason the resident does not press the telephone keys to g rant or deny access or does not hang up, the system will automatically disconnect the visitor after 60 seconds. At ten and fi v e seconds before the disconnect a tone will sound on the telep ...

  • Linear AE-100 - page 20

    20 FUNCTION CODE LOCAL PROGRAMMING TELEPHONE PROGRAMMING 74 A UTOMA TIC TELEPHONE ANSWER The factory setting will allow the system to detect a ring signal on the telephone line and answer the call. NO TE: The automatic ans wer feature can be turned off, although remote programming, remote access control by residents, and resident call-back features ...

  • Linear AE-100 - page 21

    21 FUNCTION CODE LOCAL PROGRAMMING TELEPHONE PROGRAMMING 91 EXIT PROGRAMMING MODE Entering this command number will cause the unit to exit programming mode and return to normal operation. Step 1 T o exit prog ramming mode, enter Function Code 91, then press #. NO TE: The AE-100 will automatically exit Progr amming Mode after fi ve min utes of prog ...

  • Linear AE-100 - page 22

    22 AE-1 00 Operation Requesting Access with a Visitor Call If the visitor already knows the resident’ s Director y Code number , they can press fi rst, then enter the Director y Code number to call the resident. If the visitor doesn’t know the residents Directory Code number , they can scroll through the alphabetical directory entries by press ...

  • Linear AE-100 - page 23

    23 T r oubleshooting System will not answer an incoming call 1. Automatic telephone ans wer disabled. 2. AE-100 telephone line trouble . Keypad will not activate a relay 1. Entr y code is not assigned. 2. K eypad ma y be in lockout from too man y incorrect attempts. W ait 90 seconds for loc kout to clear and try again. Resident’ s T elephone does ...

  • Linear AE-100 - page 24

    Copyright © 2007 Linear LLC 227354 B ...

メーカー Linear カテゴリー Telephone

Linear AE-100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AE-100の取扱説明書
- Linearの製品カード
- パンフレット
- またはLinear AE-100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Linear AE-100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Linear AE-100の取り付け説明書、サービスマニュアル、簡易説明書、またはLinear AE-100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Linear AE-100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Linear AE-100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLinear AE-100を使用するのを助ける技術的文書のことです。説明書は通常、全てのLinear AE-100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Linearの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Linear AE-100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLinear AE-100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Linear AE-100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Linear AE-100デバイスの基本機能を使うにあたってのヒント。 Linear AE-100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Linear AE-100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLinear AE-100のメーカー/サービスへの連絡先に関する情報。

Linear AE-100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLinear AE-100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLinear AE-100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)