    SPLIT AIR CONDITIONER OUTDOOR SECTION Models: HAC181-AD040 HAC241-AD040 HAC301-AD040 HAC361-AD040 HAC421-AD040 HAC481-AD040 HAC481-BD040 HAC601-AD040 HAC601-BD040 FOR USE WITH: MA TCHING INDOOR BLOWER COIL UNITS AND MA TCHING ADD ON COIL UNITS ONL Y INST ALLA TION INSTRUCTIONS Manual No.: 2100-346C Supersedes: 2100-346B File: V olume 1, T ab 4 Date ...

  • Bard HAC601-BD040 - page 2

    CONTENTS Split Air Conditioner General Information ......... 1 Split Air Conditioner Model Nomenclature ............... 1 Application and Location .................................... 4 General .................................................................... 4 Shipping Damage .................................................... 4 Application .. ...

  • Bard HAC601-BD040 - page 3

    Manual 2100-346 Page 1 SPLIT AIR CONDITIONER MODEL NOMENCLATURE TABLE 1 UNIT DIMENSIONS . o N l e d o M " W " h t d i W " D " h t p e D " H " t h g i e HA B C E F 1 8 1 C A H 1 4 2 C A H 0 0 . 0 40 0 . 5 10 0 . 6 25 2 1 . 58 8 1 . 0 20 0 . 45 2 1 . 78 8 1 . 4 2 1 0 3 C A H 1 6 3 C A H 0 0 . 5 40 0 . 5 10 0 . 6 25 2 1 . ...

  • Bard HAC601-BD040 - page 4

    Manual 2100-346 Page 2 w o l f r i A d e t a R g n i s n e d n o C t i n U . o N l e d o M r o t a r o p a v E l i o C . o N l e d o M M F C e r u s s e r P H p o r D 2 O d e t a R . P . S . E r o t o M d e e p S p a T d e d n e m m o c e R e g n a R w o l F r i A m e t s y S e c i f i r O d e r i u q e R A - 1 8 1 C A H A - S A 0 3 A A - S A 4 2 S ...

  • Bard HAC601-BD040 - page 5

    Manual 2100-346 Page 3 TABLE 3 SPECIFICATIONS S L E D O MA - 1 8 1 C A HA - 1 4 2 C A HA - 1 0 3 C A HA - 1 6 3 C A HA - 1 2 4 C A HA - 1 8 4 C A HB - 1 8 4 C A HA - 1 0 6 C A HB - 1 0 6 C A H ) H P / V / Z H 0 6 ( g n i t a R l a c i r t c e l E1 - 8 0 2 / 0 3 21 - 8 0 2 / 0 3 21 - 8 0 2 / 0 3 21 - 8 0 2 / 0 3 21 - 8 0 2 / 0 3 21 - 8 0 2 / 0 3 23 ...

  • Bard HAC601-BD040 - page 6

    Manual 2100-346 Page 4 APPLICA TION and LOCA TION GENERAL These instructions explain the recommended method to install the air cooled remote type condensing unit, the interconnecting refrigerant tubing and the electrical wiring connections to the unit. The condensing units are to be used in conjunction with the matching evaporator coils or evaporat ...

  • Bard HAC601-BD040 - page 7

    Manual 2100-346 Page 5 SWEAT STYLE TUBING CONNECTIONS: SWEAT INDOOR UNIT and SWEAT OUTDOOR UNIT Use only refrigeration grade (dehydrated and sealed) copper tubing. Care must be taken to insure that the tubing is kept clean and dry before and during installation. Do not remove the plugs from the tubing ends, coil connections or base valves until the ...

  • Bard HAC601-BD040 - page 8

    Manual 2100-346 Page 6 A copper-silver alloy with a high silver content should be used when iron or steel material is involved in the joint. These alloys require the use of silver solder flux. Alloys containing phosphorus should not be used with iron or steel. Phosphorus reacts with the iron forming iron phosphate which is extremely brittle. CAUTIO ...

  • Bard HAC601-BD040 - page 9

    Manual 2100-346 Page 7 NOTE: Do not make any tubing connection at indoor unit at this time. Make all brazing of joints and evacuate both suction and liquid line first. 3. Wrap a wet rag around the copper stub before brazing. 4. Flux the copper tube and insert into the stub. Braze the joint using an alloy of silver or copper and phosphorus with a me ...

  • Bard HAC601-BD040 - page 10

    Manual 2100-346 Page 8 16. Lubricate male half diaphragm and synthetic rubber seal with refrigerant oil. Thread coupling halves together by hand to insure proper mating of threads. Be sure to hold the coupling firmly to prevent movement of the coupling and tubing. Failure to do so could tear out the diaphragm causing a blockage of the system. Use p ...

  • Bard HAC601-BD040 - page 11

    Manual 2100-346 Page 9 WIRING INSTRUCTIONS GENERAL All wiring must be installed in accordance with the National Electrical Code and local codes. In Canada, all wiring must be installed in accordance with the Canadian Electrical Code and in accordance with the regulations of the authorities having jurisdiction. Power supply voltage must conform to t ...

  • Bard HAC601-BD040 - page 12

    Manual 2100-346 Page 10 ...

  • Bard HAC601-BD040 - page 13

    Manual 2100-346 Page 11 ...

  • Bard HAC601-BD040 - page 14

    Manual 2100-346 Page 12 FIGURE 5 COMPONENT MOUNTING LOCATION OPTIONAL CONTROLS MIS-1302 INSTALLATION INSTRUCTIONS — CMA-5 Disconnect all power to the unit. Remove control panel cover. 1. Mount compressor TDR in position shown in Figure 5 with screw provided. 2. Disconnect yellow low voltage (Y) wire at the compressor contactor coil and reconnect ...

  • Bard HAC601-BD040 - page 15

    Manual 2100-346 Page 13 INSTALLATION INSTRUCTIONS – CMA-10A Disconnect all power to unit. Remove control panel cover. 1. Screw compressor control module and terminal block into control panel as shown in Figure 5. 2. Disconnect yellow low voltage wire form compressor contactor and reconnect to terminal “Y” of the compressor control module. 3. ...

  • Bard HAC601-BD040 - page 16

    Manual 2100-346 Page 14 INSTALLATION INSTRUCTIONS – CMA-13A Disconnect all power to unit. Remove control panel cover. 1. Screw compressor control module and terminal block into control panel as shown in Figure 5. 2. Disconnect yellow low voltage wire from compressor contactor and reconnect to terminal “Y” of the compressor control module. 3. ...

  • Bard HAC601-BD040 - page 17

    Manual 2100-346 Page 15 PRESSURE SERVICE PORTS High and low pressure service ports are installed on all units so that the system operating pressures can be observed. Pressure tables can be found later in the manual covering all models. It is imperative to match the correct pressure table to the unit by model number. SYSTEM START-UP (INDOOR UNITS WI ...

  • Bard HAC601-BD040 - page 18

    Manual 2100-346 Page 16 n o i t c e S r o o d t u On o i t c e S r o o d n I 2 2 - R l a t o T ) . z O ( e g r a h C A - 1 8 1 C A H A - S A 0 3 A A - S A 4 2 S B 4 2 C B . z o 3 7 . z o 3 7 . z o 8 7 A - 1 4 2 C A H A - S A 0 3 A A - S A 4 2 S B 4 2 C B . z o 0 8 . z o 0 8 . z o 9 7 A - 1 0 3 C A H A - S A 6 3 A B 6 3 C B . z o 4 8 . z o 5 9 A - 1 ...

  • Bard HAC601-BD040 - page 19

    Manual 2100-346 Page 17 SERVICE SERVICE HINTS 1. Caution homeowner to maintain clean air filters at all times. Also, not to needlessly close off supply and return air registers. This reduces air flow through the system, which shortens equipment service life, as well as, increasing operating costs. 2. Check all power fuses or circuit breakers to be ...

  • Bard HAC601-BD040 - page 20

    Manual 2100-346 Page 18 ...

  • Bard HAC601-BD040 - page 21

    Manual 2100-346 Page 19 ...

  • Bard HAC601-BD040 - page 22

    Manual 2100-346 Page 20 TABLE 13 PRESSURE TABLE HAC181-A Low side pressure ± 2 PSIG (suction line 8 inches from compressor) High side pressure ± 5 PSIG ( discharge line 8 inches from compressor , liquid at base valve approximately -20 PSIG from values listed) T ests are based upon rated CFM (airflow) across the evaporator coil. If there is any do ...

  • Bard HAC601-BD040 - page 23

    Manual 2100-346 Page 21 TABLE 15 PRESSURE TABLE HAC301-A Low side pressure ± 2 PSIG (suction line 8 inches from compressor) High side pressure ± 5 PSIG ( discharge line 8 inches from compressor , liquid at base valve approximately -20 PSIG from values listed) T ests are based upon rated CFM (airflow) across the evaporator coil. If there is any do ...

  • Bard HAC601-BD040 - page 24

    Manual 2100-346 Page 22 TABLE 17 PRESSURE TABLE HAC 421-A Low side pressure ± 2 PSIG (suction line 8 inches from compressor) High side pressure ± 5 PSIG ( discharge line 8 inches from compressor , liquid at base valve approximately -20 PSIG from values listed) T ests are based upon rated CFM (airflow) across the evaporator coil. If there is any d ...

  • Bard HAC601-BD040 - page 25

    Manual 2100-346 Page 23 TABLE 19 PRESSURE TABLE HAC601-A, HAC601-B Low side pressure ± 2 PSIG (suction line 8 inches from compressor) High side pressure ± 5 PSIG ( discharge line 8 inches from compressor , liquid at base valve approximately -20 PSIG from values listed) T ests are based upon rated CFM (airflow) across the evaporator coil. If there ...

メーカー Bard カテゴリー Air Conditioner

Bard HAC601-BD040のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HAC601-BD040の取扱説明書
- Bardの製品カード
- パンフレット
- またはBard HAC601-BD040の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bard HAC601-BD040の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bard HAC601-BD040の取り付け説明書、サービスマニュアル、簡易説明書、またはBard HAC601-BD040のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bard HAC601-BD040の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bard HAC601-BD040デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBard HAC601-BD040を使用するのを助ける技術的文書のことです。説明書は通常、全てのBard HAC601-BD040ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bardの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bard HAC601-BD040の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBard HAC601-BD040の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bard HAC601-BD040に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bard HAC601-BD040デバイスの基本機能を使うにあたってのヒント。 Bard HAC601-BD040のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bard HAC601-BD040に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBard HAC601-BD040のメーカー/サービスへの連絡先に関する情報。

Bard HAC601-BD040についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBard HAC601-BD040の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBard HAC601-BD040で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)