    MODEL 4105 SERIES GAS SENSOR MODULE WITH DIGI TAL DISPL AY AND NON-INTRUSIVE CALIBR ATION 4-20 mA ...

  • Sierra Monitor Corporation 4105 - page 2

    Sierra Monitor Corporation 1991 T arob Court, Milpitas, C A 95035 (408) 262-66 11 (800) 727-4377 Fax: (408) 262-9042 E-Mail: sierra@sierramonito r .com MODEL 4105 SERIES GAS SENSOR MODULE WITH DIGI TAL DISPL AY AND NON-INTRUSIVE CALIBR ATION 4-20 mA APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor p ...

  • Sierra Monitor Corporation 4105 - page 3

    TABLE OF CONTENTS SECTION PAGE 1. PRODUCT DESCRIPTION 1 1.1 Introduction 1 1.2 Application 1 1.3 Configuration 1 1.3.1 Electronics 1 1.3.2 Sensor 1 2. CAUTIONS WARNINGS & RECOMMEND A TIONS 2 2.1 Introduction 2 2.2 Wiring 2 2.3 Sensor Modules - General 2 2.4 Preventative Maintenance 2 3. QUICK S TART 3 3.1 Overview 3 3.2 Wiring 3 3.3 Module Inst ...

  • Sierra Monitor Corporation 4105 - page 4

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 1 1. PRODUCT DESCRIPTION 1.1 Introduction Model 4105 Series Gas Sensor module features non- intrusive calibration, 4-20 mA output signal and local continuous display of the gas concentration in ppm (toxics), % LEL (Combustibles), or % vol (Oxygen). It is designed for use with industry st ...

  • Sierra Monitor Corporation 4105 - page 5

    Model 4105 Gas Sensor Module (12/02) Page: 2 Instruction Manual 2. CAUTIONS WARNINGS & RECOMMEND ATIONS 2.1 INTRODUCTION Although the sensor module is designed and con- structed for installation and operation in industrial applications including “hostile” environments, cau- tion should be taken to insure that the installation is in complian ...

  • Sierra Monitor Corporation 4105 - page 6

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 3 3. QUICK S TART 3.1 Overview The gas sensor module has been supplied factory cali- brated and ready for immediate installation and opera- tion. An installer familiar with installation and opera- tion of gas detection products can use this section to begin immediate use of the monito r. ...

  • Sierra Monitor Corporation 4105 - page 7

    Model 4105 Gas Sensor Module (12/02) Page: 4 Instruction Manual 4. OPER ATION 4.1 Introduction Under normal conditions the sensor module does not require operator or technician intervention. The fol- lowing are conditions under which the module requires attention: - Routine periodic calibration. - Calibration after a high gas alarm. - Sensor replac ...

  • Sierra Monitor Corporation 4105 - page 8

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 5 Model Gas Min. Flow Rate (cc/min) 4105-02 CH 4 100 4105-03 O 2 100 4105-04 CO 150 4105-05 H 2 S 300 4105-06 Cl 2 300 4105-07 H 2 300 4105-10 SO 2 300 4105-12 NO 2 300 4105-21 HCl 300 4105-22 HCN * 300 4105-25** NH 3 400 4105-26 HF 500 *Note: SO 2 may be used instead of HCN to calibrate ...

  • Sierra Monitor Corporation 4105 - page 9

    Model 4105 Gas Sensor Module (12/02) Page: 6 Instruction Manual 6. SERVICE 6.1 Sensor Module Configuration The gas sensor module is comprised of the following sub assemblies: 4105-XX Gas Sensor Module -SPM25002 Transmitter Assembly -SPT25013 Combustible Gas Sensor Module Transmitter Assembly -SPM25003 Oxygen and Toxic Gas Sensor Module Transmitter ...

  • Sierra Monitor Corporation 4105 - page 10

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 7 6.4a. Combustibles 1. V erify the voltage across A to R equals 2 volt. If not, adjust volts potentiometer R11 2. V erify the voltage from GND (TB2) to VOUT equals 0.4 volts. If not adjust BAL potentiom- eter (R2) 3. V erify that the voltage at VOUT is equal to the voltage desired. • ...

  • Sierra Monitor Corporation 4105 - page 11

    Model 4105 Gas Sensor Module (12/02) Page: 8 Instruction Manual 7. INS TALLATION 7.1 Sensor Locations Select locations for each of the sensors based on the following: - Consider the density of the gas to determine height of sensor above floor or ground level. - Sensors should be placed close to the potential source of gas. - Sensors should be place ...

  • Sierra Monitor Corporation 4105 - page 12

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 9 Figure 7.2 Wiring Diagram Combustible P 1 T B 1 T B 2 R I B B O N C A B L E T O C P U A S S Y . V O U T J P 1 1 3 2 4 U 2 U 4 U 5 R A C U 3 V O L T S B A L R 2 R 1 1 U 1 Sen sor P w r./Sig. Black Brown Red T oxics P 1 T B 1 T B 2 R I B B O N C A B L E T O C P U A S S Y . V O U T J P 2 ...

  • Sierra Monitor Corporation 4105 - page 13

    Model 4105 Gas Sensor Module (12/02) Page: 10 Instruction Manual Model 4105-02 4105-03 4105-04 4105-05 4105-06 4105-07 4105-10 Gas Comb. O 2 CO H 2 S Cl 2 H 2 SO 2 Sensor Type Catalytic E.C. E.C. E.C E.C. E.C. E.C. Units %LEL % Vol ppm ppm ppm ppm ppm Range 0-100 0-25% 0-1000 0-100 0-10 0-1000 0-100 Resolution 3% F .S. 0.1% F .S. 1 0.1 0.1 2 0.5 Re ...

  • Sierra Monitor Corporation 4105 - page 14

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 11 Model 4105-12 4105-21 4105-22 4105-25 3 4105-26 3 Gas NO 2 HCL HCN NH 3 HF Sensor Type E.C. E.C. E.C. E.C. E.C. Units ppm ppm ppm ppm ppm Range 0-20 0-20 0-20 0-50 0-10 Resolution 0.2 0.5 0.1 0.1 0.5 Response Time 35 sec. 150 sec 70 sec. 45 sec. 30 sec. to 90% of signal Sensor Life 2 ...

  • Sierra Monitor Corporation 4105 - page 15

    Model 4105 Gas Sensor Module (12/02) Page: 12 Instruction Manual Model Gas Reading from 100 ppm of interfering gas Number Type CO H 2 S Cl 2 H 2 SO 2 NO 2 NO HCl HCN C 2 H 4 4105-04 CO 100 315 -15 <40 50 -55 30 2 40 <50 4105-05 H 2 S <0.5 100 -20 <0.1 <15 -15 0 0 0 0 4105-06 Cl 2 0 <-10 100 0 0 105 0 0 0 0 4105-07 H 2 <1 <20 ...

  • Sierra Monitor Corporation 4105 - page 16

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 13 10. LIMITED WARRANTY SIERR A MONITOR CORPOR A TION warrants its products to be free from defects in workmanship or material under normal use and service for two years after date of shipment. SMC will repair or replace without charge any equipment found to be defective during the warra ...

  • Sierra Monitor Corporation 4105 - page 17

    Model 4105 Gas Sensor Module (12/02) Page: 14 Instruction Manual Appendix A: Unity Gain Mode The Unity magnetic control is available during CAL MODE to allow the ZERO and S PAN adjustments to be centered within their range. This is similar to setting a potentiometer so the wiper terminal is exactly halfway between the clockwise and counterclockwise ...

  • Sierra Monitor Corporation 4105 - page 18

    Instruction Manual Model 4105 Gas Sensor Module (12/02) Page: 15 Appendix C: Combustible Gas Scaling Factors ( T able 1) Where possible, calibration gas should be the same as the gas to be detected. If this is not possible then a scaling factor should be used to determine the “equivalent value” of the calibration gas in terms of the gas to be d ...

  • Sierra Monitor Corporation 4105 - page 19

    Model 4105 Gas Sensor Module (12/02) Page: 16 Instruction Manual GAS METHANE PROPANE FACTOR FACTOR Acetaldehyde 60 109 Acetic Acid 54 98 Acetic Anhydride 46 83 Acetone 52 94 Acetylene 57 103 Alkyl Alcohol 51 92 Ammonia 126 229 n-Amyl Alcohol 33 59 Aniline 39 71 Benzene 41 74 Biphenyl 25 45 1,3-Butadiene 56 101 n-Butane 58 106 iso-Butane 52 94 Buten ...

メーカー Sierra Monitor Corporation カテゴリー Stud Sensor

Sierra Monitor Corporation 4105のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 4105の取扱説明書
- Sierra Monitor Corporationの製品カード
- パンフレット
- またはSierra Monitor Corporation 4105の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sierra Monitor Corporation 4105の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sierra Monitor Corporation 4105の取り付け説明書、サービスマニュアル、簡易説明書、またはSierra Monitor Corporation 4105のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sierra Monitor Corporation 4105の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Sierra Monitor Corporation 4105デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSierra Monitor Corporation 4105を使用するのを助ける技術的文書のことです。説明書は通常、全てのSierra Monitor Corporation 4105ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sierra Monitor Corporationの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sierra Monitor Corporation 4105の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSierra Monitor Corporation 4105の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sierra Monitor Corporation 4105に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sierra Monitor Corporation 4105デバイスの基本機能を使うにあたってのヒント。 Sierra Monitor Corporation 4105のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sierra Monitor Corporation 4105に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSierra Monitor Corporation 4105のメーカー/サービスへの連絡先に関する情報。

Sierra Monitor Corporation 4105についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSierra Monitor Corporation 4105の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSierra Monitor Corporation 4105で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)