B&B Electronics RS-232 Digital I/O Module 232SDD16の取扱説明書

27ページ 0.62 mb
ダウンロード

ページに移動 of 27

Summary
  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 1

    232SDD16-1005 Manual Cover Page B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 RS-232 Digital I/O Module Model 232SDD16 Documentation Num ber 232SDD16-1005 pn#3604-r1 This product Designed and Manufactured In Ottawa, Il lin ois USA of domestic and imported pa rts by B&B Electronics Mfg. Co. Inc. ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 2

    232SDD16-1005 Manual Table of Contents i B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Table of Contents Chapter 1 - Introduction ........................................... 1 232SDD16 Features ............................... ................ 1 Packing List ................................. ....... ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 3

    232SDD16-1005 Manual 1 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Chapter 1- Introduction 232SDD16 Features The 232SDD16 is a genera l purpose control module t hat is connected to your compu ter’s RS-232 serial port. The 232SDD16 offers 16 discrete digital I/O lin es. With t hese fe atures, th ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 4

    232SDD16-1005 Manual 3 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 232SDD16 Specif i cations I/O Lines Total: 16 (Factory def ault = inp uts) Digital Inputs Voltage Range: 0 Vdc to 5 Vdc Low Voltage: 1.0 Vdc ma x. High Voltage: 2.0 Vdc min. Leakage Current: 1 microamp max. Digital Outputs Low Vol ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 5

    232SDD16-1005 Manual 5 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Chapter 2 - Connections This chapter will cover the connections re quired for the 232SDD16. There are three sets of conne ction s: digit al I/ O, serial port, and power supply. Do not make any connections to the 232SDD16 until you ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 6

    232SDD16-1005 Manual 7 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Table 2.2 - RS-232 Connector Pinout DB-25S Pin # Signal Signal Direction at 232SDD16 Notes 2 Transmit Data (TD) Input Connection is required. 3 Receive Data (RD) Output Connection is required. 4 Request to Send (RTS) Input May be ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 7

    232SDD16-1005 Manual 9 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Chapter 3 - Commands There are only two commands required to control the 232SDD16: set output l ines, and read I/O lines. Three ad ditional commands are used for configuring the module: defin e I/ O lines, set power-up states, and ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 8

    232SDD16-1005 Manual 11 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 A byte represents an eight-bit binary number (11111111 ), therefore each byte can represent eight I/ O li nes. Each bit is assigned a bit position and a weight (value). Refer to Table 3.3. To set an output to a HIGH state the cor ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 9

    232SDD16-1005 Manual 13 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Command: !0SO Argument: {I/O msb}{I/O lsb} Response: none ASCII Example: !0SOUA Dec. Example: !0SO<85><65> Hex. Example: !0SO <55><41> Bin. Examp le: !0S O<01010101><01000001> Description: the ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 10

    232SDD16-1005 Manual 15 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Command: !0RC Argument: none Response: definition of the sixteen I /O lines in two 8 bit bytes, and the power-up states in two 8 bit bytes. (shown in bo ld face) ASCII Example: !0RC UAP@ Dec. Example: !0RC< 85 >< 65 > ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 11

    232SDD16-1005 Manual 17 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Chapter 4 - I/O Interfacing This chapter will explain "HIGH" and "LOW" states and show some general examples of how to interface to t he I/O lines. Caution must be taken not to exceed 232SDD16 specifications l ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 12

    232SDD16-1005 Manual 19 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Figure 4.4 - Isolated Solid State Input Digital Outputs Digital outputs are used to turn external devices on or off. Digital outputs are CMOS/TTL compatible and oper ate between 0Vd c and +5Vdc. Outputs can be used to control sol ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 13

    232SDD16-1005 Manual 21 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Chapter 5 - Software This chapter will be divided into two sections. The first section covers programming techniques for constructing a command st ring, receiving data and manipulating dat a in QuickBAS IC. The second section dis ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 14

    232SDD16-1005 Manual 23 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Step 5 - Determining the I/O line de fin i tio ns: MSdefs = MSdefs AND mask LSdefs = LSdefs AND mask By "ANDing" the value of MSdefs or LSdefs with the app ropr iat e mask of an I/O line, the I/O line defin ition can be ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 15

    232SDD16-1005 Manual 25 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Define I/O Lines Command Step 1a - Constr uc t the command strin g: Define an I/O line as Output MSdefs = MSdefs OR mask LSdefs = LSdefs OR mask By "ORing" the current definition s with the approp riat e I/ O line mask ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 16

    232SDD16-1005 Manual 27 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Demonstration Program The 232SDD16 Demonstration (SDD16) Program (IBM PC or Compatible) provides the user with examples of how t o receive and transmit commands to the 232SDD16. The SDD16.EX E is the executable pr ogram, the SDD1 ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 17

    232SDD16-1005 Manual Appendix A A-1 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 APPENDIX A ASCII Character Codes A-2 Appendix A 232SDD16-1005 Manual B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 DECIMAL to HEX to ASCII CONVERSION TABLE DEC HEX AS ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 18

    232SDD16-1005 Manual Appendix B B-1 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 APPENDIX B Hexadecimal/Decimal Conversions B-2 Appendix B 232SDD16-1005 Manual B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 The decimal (base 10) numbe ring system r ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 19

    232SDD16-1005 Manual Appendix B B-3 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Hexadecimal to Decimal Conve rsion: Decimal = (1st Hex digit x 4096) + (2nd Hex digit x 256) + (3rd Hex digit x 16) + (4th Hex digit) E ach "Hex digit " is the decimal equivalen t value of the hexadecimal sy ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 20

    232SDD16-1005 Manual Appendix C C-1 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 APPENDIX C Interface Modules for SDD16 Models C-2 Appendix C 232SDD16-1005 Manual B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 DTB25 The DTB25 connects to the SDD16 ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 21

    232SDD16-1005 Manual Appendix C C-3 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Table C.1 - DTB25 Connections DB-25P Pin # Function T.B. # DB-25P Pin # Function T.B. # 1 Unused. 1 14 I/O #15 14 2 Unused. 2 15 I/O #14 15 3 Unused. 3 16 I/O #13 16 4 Unused. 4 17 I/O #12 17 5 Unused. 5 18 I/O #11 18 ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 22

    232SDD16-1005 Manual Appendix C C-5 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 DBM16 Interfacing This section will show some general examples of how to interface the DBM16 I/O lines to ext ernal devices. Caution mu st be taken not to exceed the DB M16 specifications, failur e to do so could resu ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 23

    232SDD16-1005 Manual Appendix C C-7 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Figure C.6 - Isolated Solid State Input Outputs Digital outputs are used to turn "ON" or turn "O FF" ext erna l devices. Outputs can be used to control solid state outp ut modu les, logic circuits, ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 24

    232SDD16-1005 Manual Appendix C C-9 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 DBM16 Specifications I/O Lines Total: 16 (Factor y default - set to inputs ) Inputs Voltage range: 0Vdc to +50Vdc Low Voltage: 0Vdc to +1.5Vdc High Voltage: +2.5Vdc to +50Vdc Internal pull-up curr ent: 0.5 ma Outputs ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 25

    232SDD16-1005 Manual Appendix C C-11 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 26

    232SDD16-1005 Manual Appendix D D-1 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Appendix D Adding Data Field Confirmation D-2 Appendix D 232SDD16-1005 Manual B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 With serial communications in a laboratory ...

  • B&B Electronics RS-232 Digital I/O Module 232SDD16 - page 27

    232SDD16-1005 Manual Appendix D D-3 B&B Electronics -- PO Bo x 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 43 3-5104 Table D-1 Extended Commands Function Comma nd Respon se Read I/O Lines #0R D {I/O msb }{~I/O ms b}{I/O lsb}{~I/O lsb} Set Output Lin es #0 SO{I/O msb}{~I/O msb}{I/O lsb}{~I/O lsb} no response Define I/O Lines #0SD{I/O ...

メーカー B&B Electronics カテゴリー Network Card

B&B Electronics RS-232 Digital I/O Module 232SDD16のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RS-232 Digital I/O Module 232SDD16の取扱説明書
- B&B Electronicsの製品カード
- パンフレット
- またはB&B Electronics RS-232 Digital I/O Module 232SDD16の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、B&B Electronics RS-232 Digital I/O Module 232SDD16の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、B&B Electronics RS-232 Digital I/O Module 232SDD16の取り付け説明書、サービスマニュアル、簡易説明書、またはB&B Electronics RS-232 Digital I/O Module 232SDD16のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、B&B Electronics RS-232 Digital I/O Module 232SDD16の製品を使用するにあたって最も人気のある説明書を閲覧できます。

B&B Electronics RS-232 Digital I/O Module 232SDD16デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがB&B Electronics RS-232 Digital I/O Module 232SDD16を使用するのを助ける技術的文書のことです。説明書は通常、全てのB&B Electronics RS-232 Digital I/O Module 232SDD16ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

B&B Electronicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. B&B Electronics RS-232 Digital I/O Module 232SDD16の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははB&B Electronics RS-232 Digital I/O Module 232SDD16の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。B&B Electronics RS-232 Digital I/O Module 232SDD16に関してこのドキュメントで見つけることができる全てのヒントの目次
3. B&B Electronics RS-232 Digital I/O Module 232SDD16デバイスの基本機能を使うにあたってのヒント。 B&B Electronics RS-232 Digital I/O Module 232SDD16のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。B&B Electronics RS-232 Digital I/O Module 232SDD16に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるB&B Electronics RS-232 Digital I/O Module 232SDD16のメーカー/サービスへの連絡先に関する情報。

B&B Electronics RS-232 Digital I/O Module 232SDD16についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもB&B Electronics RS-232 Digital I/O Module 232SDD16の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがB&B Electronics RS-232 Digital I/O Module 232SDD16で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)