  • Empire Comfort Systems LSU18RR-1 - page 1

    INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL LOG SET FOR VENTED AND UNVENTED MUL TI-SIDED GAS LOG HEA TER MODELS LSU18RR-1 LSU24RR-1 LSU30RR-1 W ARNING: If not installed, operated and main- tained in accordance with the manufactur er's instructions, this pr oduct could expose you to sub- stances in fuel or from fuel combustion which can ...

  • Empire Comfort Systems LSU18RR-1 - page 2

    23370-1-1 107 Page 2 Section Page Important Installation Guidelines ......................................................................... 3 General Information ............................................................................................. 3 Log Placement ............................................................................ ...

  • Empire Comfort Systems LSU18RR-1 - page 3

    23370-1-1 107 Page 3 Proper Log Placement Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner . The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs. Logs must fit firmly onto the burner ...

  • Empire Comfort Systems LSU18RR-1 - page 4

    23370-1-1 107 Page 4 PROPER INST ALLA TION SEQUENCE: A TTENTION: For the instructions below , "Front" indicates the side of the burner with the valve. 1. W ith the valve "front" side facing you, place Back Right Log (log A) onto right back pins of burner . 2. Place Right Middle Log (log B) onto right middle pins of burner . 3. P ...

  • Empire Comfort Systems LSU18RR-1 - page 5

    23370-1-1 107 Page 5 8. Insert boss of Middle Bottom Branch (log H) onto recess on logs E, B, and C. 9. Insert boss of Middle T op Branch (log I) onto recess on log H (Center Branch) and logs A and B. Note: Omit this step for 18" log sets. 10. Insert boss of T op Left Branch (log K) into recess of logs C, D, and G). 1 1. Insert recess of T op ...

  • Empire Comfort Systems LSU18RR-1 - page 6

    23370-1-1 107 Page 6 Apply loose material (glowing embers) per appropriate Installation Instructions and Owner's Manual. Replacement of loose material (glowing embers) must be purchased from Empire Comfort Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater . W ARNING: All previous ...

  • Empire Comfort Systems LSU18RR-1 - page 7

    23370-1-1 107 Page 7 EMBER PLACEMENT LSU18RR-1 PHOTOS Some logs have been removed for clarity Do not cover any large ports with loose material (glowing embers) Front View (V alve Side) Rear View T op V iew ...

  • Empire Comfort Systems LSU18RR-1 - page 8

    23370-1-1 107 Page 8 EMBER PLACEMENT LSU24RR-1 PHOTOS Some logs have been removed for clarity Do not cover any large ports with loose material (glowing embers) Front View (V alve Side) Rear View T op V iew ...

  • Empire Comfort Systems LSU18RR-1 - page 9

    23370-1-1 107 Page 9 EMBER PLACEMENT LSU30RR-1 PHOTOS Some logs have been removed for clarity Do not cover any large ports with loose material (glowing embers) Front View (V alve Side) Rear View T op V iew ...

  • Empire Comfort Systems LSU18RR-1 - page 10

    23370-1-1 107 Page 10 Attention: When ordering parts, it is very important that part number and description of part coincide. USE ONL Y MANUF ACTURER'S REPLACEMENT P ARTS. USE OF ANY OTHER P ARTS COULD CAUSE INJUR Y OR DEA TH. Index No. Part Number LSU18RR-1 Part Number LSU24RR-1 Part Number LSU30RR-1 Description A R9312 R9323 R9329 BACK RIGHT ...

  • Empire Comfort Systems LSU18RR-1 - page 11

    23370-1-1 107 Page 1 1 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distribu- tor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number . When ordering parts, first obtain the Model Numbe ...

  • Empire Comfort Systems LSU18RR-1 - page 12

    23370-1-1 107 Page 12 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

メーカー Empire Comfort Systems カテゴリー Gas Heater

Empire Comfort Systems LSU18RR-1のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LSU18RR-1の取扱説明書
- Empire Comfort Systemsの製品カード
- パンフレット
- またはEmpire Comfort Systems LSU18RR-1の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Empire Comfort Systems LSU18RR-1の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Empire Comfort Systems LSU18RR-1の取り付け説明書、サービスマニュアル、簡易説明書、またはEmpire Comfort Systems LSU18RR-1のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Empire Comfort Systems LSU18RR-1の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Empire Comfort Systems LSU18RR-1デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmpire Comfort Systems LSU18RR-1を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmpire Comfort Systems LSU18RR-1ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Empire Comfort Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Empire Comfort Systems LSU18RR-1の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmpire Comfort Systems LSU18RR-1の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Empire Comfort Systems LSU18RR-1に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Empire Comfort Systems LSU18RR-1デバイスの基本機能を使うにあたってのヒント。 Empire Comfort Systems LSU18RR-1のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Empire Comfort Systems LSU18RR-1に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmpire Comfort Systems LSU18RR-1のメーカー/サービスへの連絡先に関する情報。

Empire Comfort Systems LSU18RR-1についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmpire Comfort Systems LSU18RR-1の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmpire Comfort Systems LSU18RR-1で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)