Technoline WS 1600の取扱説明書

54ページ 関係なし
ダウンロード

ページに移動 of 54

Summary
  • Technoline WS 1600 - page 1

    59 FAMILY WEATHER STATION Instruction Manual INTRODUCT ION: Congratulations o n purchasing this state-of-the-art weather station as an example o f excellent design and innovative m easuring techniq ue. Featuring time, date, calendar, weather forecast, wind direction and speed, r ainfall, outdoor t emperature and outdoor humidity, air p ressure and ...

  • Technoline WS 1600 - page 2

    60 FEATU RES: The Multifunc tional Weather S tation • Time display (man ual setting) • 12/24 hour time display • Calendar displa y (weekday, date, month, year) • Time alarm functi on • W eather forecasting function with 3 weather icons and weathe r tendency indicator • Outdoor tempe rature display in °C /ºF • Outdoor Humi dity displ ...

  • Technoline WS 1600 - page 3

    61 • Relative air pres sure displa yed in hPa or inHg • Air pressure tend ency indicator f or the past 12 ho ur (bargraph fo rmat) • LCD contrast sel ectable • Low batter y indicator • W ind dir ection dis played in 16 step s • W ind speed displayed in km/h, mp h or m/s, and Be aufort scale • W ind chill displayed in ° C of ° F • ...

  • Technoline WS 1600 - page 4

    62 The Wind sen sor • Connected to the thermo-hygro tr ansmitter b y cable • Can be installed onto a mast or a horizontal p anel THE RAIN SENS OR • Connected to the thermo-hygro tr ansmitter b y cable • To be mounted onto a horizontal panel ...

  • Technoline WS 1600 - page 5

    63 Cable connection between the wind sensor and the thermo-hygro transmitter Cable connection between the rain sensor and the thermo-hygro transmitter W ireless transmission at 868 MHz - thermo- hygro transmitter to weather station Weather station Wind sensor Rain sensor SETTING UP: Note: W hen putting the Weather Station into operation, it is impo ...

  • Technoline WS 1600 - page 6

    64 important to test all components f or correct functio n before placing and mounting them at their final destinations (See Positioning below) 1. Unwind the cable s of the Rain and the W ind sensors. Connect the Rain and the Wind sensor s to the Thermo- hygro transm itter by plugging t he connector heads of the t wo sensors into t he appropriate s ...

  • Technoline WS 1600 - page 7

    65 4. Afterwards, the Weather Station will start receivi ng data from the transmitter. The outdoor temp erature, hum idity windchill and wind speed s hould then be displayed on the W eather Station. If this does not happen after 30 seconds, th e batteries will nee d to be remov ed from both units. You will have to st art again from step 1. 5. You m ...

  • Technoline WS 1600 - page 8

    66 Note : • After batteries ar e installed in tr ansmitter, user shall also power up the weather station to receive t he signal from t he transmitter as soon as possi ble. If the weather statio n is powered after a bout more than 5 hours the tran smitter is powered, the wea ther station will never receive sign al successfully fr om this transmitt ...

  • Technoline WS 1600 - page 9

    67 HOW TO INST ALL AND REP LACE THE BAT TERIES INTO THE WEATHER STATION The W eather Station works with 3 x AA, IEC LR6, 1.5V batte ries. W hen the batteries need to be repl aced, the low batt ery symbol will appear on the L CD. To install and replace the batterie s, please follo w the steps belo w: 1. Remove the batte ry compartmen t cover. 2. Ins ...

  • Technoline WS 1600 - page 10

    68 HOW TO INST ALL AND REP LACE THE BAT TERIES INTO THE THERMO- HYGRO TRANSMITTER The outdoor The rmo-hygro transm itter works with 2 x AA IEC LR 6, 1.5V batter ies. To install and repl ace the batteries, pl ease follow th e steps belo w: 1. Uninstall the rain cover of the transm itter. 2. Remover the batt ery compartme nt cover. 3. Insert the batt ...

  • Technoline WS 1600 - page 11

    69 BATTERY CH ANGE: It is recomme nded to replace the batteries in all u nits every two- year to ensure optimum accu racy of these units . Please partici pate in the pres ervation of the environme nt. Return used batterie s to an authorise d depot. Note: The stored His tory record will no t be kept after the battery change is done on the weather st ...

  • Technoline WS 1600 - page 12

    70 SET key • Press to enter ma nual setting mod es: LCD contr ast, Manual time s etting, 12/2 4 hour time displa y, Calendar setti ng, ºC/ ºF tempera ture unit, W ind speed unit, Rainfall unit, P ressure unit, Relati ve pressure ref erence setting, W eather tendency threshol d setting, Storm warning thr eshold setting an d Storm Alarm On/ Off s ...

  • Technoline WS 1600 - page 13

    71 • Press to exit the m anual setting m ode • Stop the alarm du ring the time ala rm or weathe r alarm ringing • Press to exit ma x/ min record dis play mode MIN/MAX ke y • Press to displa y minimum and ma ximum records of various weath er data • Press to adjust ( decrease) the l evel of different s ettings • Stop the alarm du ring the ...

  • Technoline WS 1600 - page 14

    72 Wind direction display and wind speed in Beaufort scale Calendar display Weather tendency indicator Time display Time alarm icon Air pressure history histogram Outdoor relative humidity in % Weather forecast icon Relative air pressure display in hPa or inHg Wind speed in km/h, mph or m/s Wind Chill in ° C or ° F Wind speed Hi/ Lo alarm icon Ou ...

  • Technoline WS 1600 - page 15

    73 MANUAL SETTIN G: The following man ual settings ca n be changed o nce the SET k ey is pressed: • LCD contrast set ting • Manual time s etting • 12/24 hour time display • Calendar settin g • °C/ °F temperat ure unit setting • W ind speed unit • Rainfall unit settin g • Air pressure u nit setting • Relative pressur e reference ...

  • Technoline WS 1600 - page 16

    74 MANUAL TIME SETTING: You then ma y manually set the tim e of the clock b y following the ste ps below: 1. The hour digit will start flashin g. 2. Use the + or MIN/MAX key to s et the hour. 3. Pre ss the SET key to switch to the minutes. T he minute di git will start flashin g. 4. Use the + or MIN/MAX key to s et the minute. 5. Co nfirm the tim e ...

  • Technoline WS 1600 - page 17

    75 Year "Date. Month." (for 24h time display) "Month. Date." (for 12h time display) 2. Co nfirm with the SET ke y and enter the CALEND AR SETTIN G . CALENDAR SE TTING: The date defaul t of the W eather Station is 1. 1. of year 2005. Th e date can be set manually by proce eding as follo ws. 1. The year digit starts flashing . 2. ...

  • Technoline WS 1600 - page 18

    76 °C/°F TEMP ERATURE UNIT SE TTING The temperature display can be selected to sho w temperature data i n °C or °F. (default °C) 1. The t emperatu re unit is flashi ng 2. Use the + or MIN/MAX key to t oggle between “ °C” or “°F”. Confirm with the SET ke y and ente r the WIND SPEE D UNIT SETT ING WIND SPEED UNI T SETTING The wind spee ...

  • Technoline WS 1600 - page 19

    77 RAINFALL UNI T SETTING The total rainfall unit can be set as mm or inch. T he default unit is m m. 1. Use the + or MIN/MAX key to t oggle between t he unit “mm” or “ Inch” 2. Co nfirm the u nit with the SET k ey and enter the R ELATIVE AIR PR ESSURE UNIT SETTING RELATIVE AIR PRESSURE UNI T SETTING The relative air p ressure can be set as ...

  • Technoline WS 1600 - page 20

    78 RELATIVE PRE SSURE REFER ENCE VALUE S ETTING Note: The default ref erence pressure val ue of the baromet er is 1013 hP a when batteries are first inserted. For an exact me asurement, it is necessary to firs t adjust the barometer t o your local relati ve air pressure (r elated to eleva tion above s ea level) . Ask for the current atmos pheric pr ...

  • Technoline WS 1600 - page 21

    79 WEATHER TENDE NCY THRESHO LD VALUE SE TTING You may select a definite switchin g threshold value , 2 hPa to 4 hPa for the change in the display of weather icons. This represents th e "sensitivity" of t he weather for ecast (the smaller the v alue selected, the more sensitiv e the weather forec ast). The def ault value is 3 hPa. 1. The ...

  • Technoline WS 1600 - page 22

    80 1. The threshold val ue will start flas hing. 2. Use the + or MIN/MAX key to selec t the value. 3. Confirm with the SET ke y and ente r the STORM ALARM ON/ OF F SETTING . STORM AL ARM ON/ OFF SE TTING You may also ch oose to switch O n or Off the aco ustic Storm war ning alarm (Default OFF). 1. The digit "AO F" will start flashing . 2. ...

  • Technoline WS 1600 - page 23

    81 Alarm-On icon be flashing. (Also see clause WE ATHER TENDENC Y INDICATOR below ) TO EXIT THE M ANUAL SETTIN G MODE To exit the manu al setting anytime during the ma nual setting mod es, press the ALARM key (or H ISTORY ke y) anytime or wait f or the automatic tim eout. The m ode will return to th e normal time dis play. TIME ALARM SETTING The al ...

  • Technoline WS 1600 - page 24

    82 4. Pre ss the + o r MIN/MAX ke y to set the m inute of the alarm tim e. Press the ALARM key to c onfirm. W ait for about 30 seconds and the displa y will return to normal displa y mode automatic ally. 5. I n the normal dis play mode, p ress the ALAR M once key to g o to the time alar m setting mode agai n. Then press s hortly the SET k ey to swi ...

  • Technoline WS 1600 - page 25

    83 The W eather Station can be set to alert when a specific weathe r condition is re ached. The following W eather Alarm settings can be a djusted in the ALARM settin g mode. • High outdoor tem perature alarm • Low outdoor tem perature alarm High wind speed Alarm- On icon Outdoor humidity Alarm-On icon Outdoor t emp Alarm- On icon ...

  • Technoline WS 1600 - page 26

    84 • High outdoor hum idity alarm • Low outdoor hum idity alarm • High wind speed alarm Default alarm values: Low 0 ° C Temperature High 40 ° C Low 45% Relative Humidity High 70% W ind speed High 100 km/h HIGH A ND LOW OUTDOOR TE MPERATU RE ALARM SETT ING Note: The High and Lo w outdoor temp erature alarm can be set On/ Off in dependentl y, ...

  • Technoline WS 1600 - page 27

    85 2. Press and hold the SET ke y for about 2 seconds. T he temperatu re digit will start flashing. Pr ess the + or MIN/ MAX k ey to set the high outd oor temp alarm value. (Keep h olding the key will allow the valu e to increase fast er.) 3. Press the ALAR M key to confirm t he setting. The digit will stop flashi ng. Press the SET ke y to switch o ...

  • Technoline WS 1600 - page 28

    86 HIGH A ND LOW OUTDOOR HUMIDITY A LARM SETTING Note: The High and Lo w outdoor hum idity alarm can be set On/ Off in dependently ac cording to your needs. Set the Outdoor temperature alarm value (H igh or Low al arm value): 1. In the normal dis play mode, press the ALAR M key four times. T he High Outdoor Humi dity alarm displa y will be shown. 2 ...

  • Technoline WS 1600 - page 29

    87 6. Press the ALAR M key to confirm t he setting. The digit will stop flashi ng. Press the SET ke y to switch on or off the alarm. (The s howing of the ico n (((  ))) means that the alarm is switched on.) 7. Press the H ISTORY key or wait f or about 30 s econds and the display will return to normal dis play mode a utomaticall y. In case the hu ...

  • Technoline WS 1600 - page 30

    88 In case the wind speed exceeds the condition for high wind speed alarm, the v alue will be flashing, al ong with the co rresponding hi gh alarm icon ("H I AL"). And th e buzzer will ring f or 2 minutes. Use r may press an y key to stop th e sound. HYSTERESIS To compensate f or fluctuation of the measured dat a, which may ca use the wea ...

  • Technoline WS 1600 - page 31

    89 WE A T HER FORECAST A ND WEATH ER TENDENCY: WEATHER FOREC ASTING IC ONS: W eather forecasting icons is displa yed in an y of the following c ombinations at t he right bottom pa rt of LCD: For every sudde n or significant ch ange in the air p ressure, the weather icons w ill update accordingl y to represent the change in weather. (Every time a n ...

  • Technoline WS 1600 - page 32

    90 The icons displa yed forecasts th e weather in terms of getting bette r or worse and not necessarily sunn y or rainy as eac h icon indicates . For example, i f the current weather is cloudy and th e rainy icon is displ ayed, it does n ot mean that t he product is faulty because it is no t raining. It simpl y means that the air pressure has dropp ...

  • Technoline WS 1600 - page 33

    91 improve, but w hen indicator points downwards, th e air-pressure is dropping an d the weather is exp ected to become worse. Taking this into account, one ca n see ho w the weather has cha nged and is expect ed to change. For example, if the in dicator is pointing d ownwards togeth er with cl oud and sun icons, then the last noticeabl e change in ...

  • Technoline WS 1600 - page 34

    92 The horizontal a xis represents th e last 12 hours air pressure rec ording (-12, -9 , -6, -3 and 0 hour). The bars are plotte d at each of th e 5 steps and giv e the trend ov er the recorded perio d. The scale on the right compares the result. The " 0" in the middle of this scale determin es the current air pressure. The vertical axis ...

  • Technoline WS 1600 - page 35

    93 RAINFALL ME A SUREMENT The total rainfall m easurement is displayed in t he fourth section of the LCD, in the unit of mm or inch. (s ee VIEWING THE M AXIMU M/ MINIMUM WEATHER DAT A below) Pointer indicates the currently detected wind direction Text showing wind speed in Beaufort scale Wind speed This alarm symbol indicates that the alarm is set ...

  • Technoline WS 1600 - page 36

    94 VIEWING THE HIS TORY D ATA The weather stati on can store u p to 200 sets of weather data which are recorded automatically at 3-hour intervals af ter the weather station is po wered up, at the nearest time of 0 :00, 03:00, 06:00 , 09:00, 12:00, 15:00, 18:00 and 21:00. For instance, if use r has manually set the time as 14: 52 after installing ba ...

  • Technoline WS 1600 - page 37

    95 2. Press MIN/ MAX to view older r ecords. (Press MIN/MA X and + key to vi ew "Previous" an d "Next" record respectively. The records ar e made at 3-hou r intervals) Note: • The stored histo ry records will n ot be retained afte r battery chan ge or wheneve r battery is remove d. • The total rainfall v alue will be e xhibi ...

  • Technoline WS 1600 - page 38

    96 VIEWING THE M AXIMUM/ M INIMUM WEATHER D ATA The weather stati on will record the maxim um and minimum valu e of the variou s weather data with time and date o f recording automa tically. The follo wing stored maximum and m inimum weathe r data can be vi ewed by pressing the MIN/MAX key in normal displa y mode. 1. Min outdoor temperature wi th t ...

  • Technoline WS 1600 - page 39

    97 4. Max outdoor humidity with th e date and time of recording MAX icon MAX outdoor humidity value Time and date or recording ...

  • Technoline WS 1600 - page 40

    98 5. Min Wind c hill temperature wi th the date and time of recordin g 6. Max Wind c hill temperature wi th the date and time of recordin g 7. Min Relati ve pressure with th e date and time of recording MIN icon MIN wind chill value Time and date or recording ...

  • Technoline WS 1600 - page 41

    99 8. Max Relati ve pressure with th e date and time of recording MAX icon MAX relativ e pressure value Time and date or recording ...

  • Technoline WS 1600 - page 42

    100 9. Maximum wi nd speed RESET THE M AXIMUM AND M INIMUM WEATHE R DATA To reset the af orementioned ma ximum or minimum weather data 1. to 9., you shall need to reset e ach of the data i ndependentl y. 1. Press MIN/MA X key to show the desired weather dat a. For instance, if you want to reset the minim um humidit y, in the normal displa y you sha ...

  • Technoline WS 1600 - page 43

    101 3. Press the + k ey once, then the st ored value will b e reset to the curr ent value a nd current time. 4. Press the ALAR M key to return t o normal displa y mode. 10. Total rainfall amount The total rainfall m easurement is displayed in t he fourth section of the LCD, in the unit of mm or inch. It shows the tot al rainfall accumul ated since ...

  • Technoline WS 1600 - page 44

    102 To reset the rai nfall reading, press the + k ey once when the Rai nfall value an d "Reset" icon is sh own. Then the t otal rainfall amoun t will be reset t o 0, and the time updated to curr ent time. Note: After power up, th e time and dat e and total rainfall is displayed as "- - -". After tim e is adjusted manuall y, the ...

  • Technoline WS 1600 - page 45

    103 To re-enable t he buzzer: 1. W hen the BUZZER OFF icon is sh own on LCD, press the SET k ey shortly and the BUZZER O FF icon will disa ppear. 2. Press ALAR M key once to return to the norm al display mode. T he "BUZZER OFF" icon will n o longer be sh own. Then the alarm will sound no rmally. LOW BATT ERY INDICATOR The low batter y ind ...

  • Technoline WS 1600 - page 46

    104 consecutive faile d attempts durin g normal operation ). Please check the following points: 1. The distance of t he Weather St ation or transmi tter should be at le ast 1.5 to 2 metres awa y from any interfering sources such as c omputer monito rs or TV sets. 2. Avoid positioni ng the W eather Station onto or in t he immediate pro ximity of met ...

  • Technoline WS 1600 - page 47

    105 POSITIONING: Prior to permane ntly affixing an y of the units, ple ase ensure the following point s are considered: • Cable lengths o f the units meet with your distance requirements at the point of fixing • Signals from the sensors can be received b y the base station at p oints of mounting The Weather S tation The W eather Station has bee ...

  • Technoline WS 1600 - page 48

    106 The Thermo-h ygro Sensor An ideal mountin g place for the the rmo-hygro sens or would be the outer wall b eneath the extension of a roof, as this wi ll protect the sen sor from direct sunlight and oth er extreme weather conditions. To wall mount, use the 2 scre ws to affix the wall bracket to the desir ed wall, plug in the thermo-h ygro sensor ...

  • Technoline WS 1600 - page 49

    107 The Wind Se nsor Firstly, check th at the wind-fan a nd the wind-van e can rotate freel y before fixin g the unit. For correc t and accurate re adings it is impo rtant to mount th e sensor so that the front (marked E) is pointing in Ea st-West directi on. The wind se nsor should no w be mounted using th e screw or cable tie provided onto a soli ...

  • Technoline WS 1600 - page 50

    108 The Rain Se nsor For best results, the rain sensor should be securel y mounted onto a horizontal surface about 1 meter above the ground and in an ope n area away from t rees or other coverings wher e rainfall may be reduced causin g inaccurate re adings. W hen securing into place, check that rain excess will not collect an d store at the base o ...

  • Technoline WS 1600 - page 51

    109 CARE AND M AINTENANCE: • Extreme temp eratures, vibrati on and shock should b e avoided as th ese may cause damage to the units and gi ve inaccurate fo recasts and rea dings. • W hen cleaning the display and casi ngs, use a soft dam p cloth onl y. Do not use solvents or scou ring agents as t hey may mark the LCD and c asings. • Do not sub ...

  • Technoline WS 1600 - page 52

    110 W ind speed : 0 to 50 m/s (0 t o 111.8 mph) (displayed "OF.L" when > 50m/s ) W ind chill : -40ºC to +59.9ºC ( -40°F to +140° F) (displayed "OF.L" i f outside this) Relative pressur e pre-set range : 919 to 1080 hPa (27.17 to 31.9 0 inHg) Rainfall : 0 to 9999 mm ( 0" to 393.6") (displ ayed "OF.L" wh ...

  • Technoline WS 1600 - page 53

    111 damages the envi ronment. • Please contact your local or/and regional authoriti es to retrieve th e addresses of legal dumpi ng grounds with s elective collection . • All electronic ins truments must f rom now on be re cycled. User sh all take an active part in t he reuse, rec ycling and recover y of the electrical a nd electronic waste. ? ...

  • Technoline WS 1600 - page 54

    112 R&TTE Directi ve 1999/5/EC Summary of th e Declaration of C onformit y : W e hereby declare th at this wireless transmission dev ice does compl y with the essential requirements of R&TTE Directive 1999/5/EC. ...

メーカー Technoline カテゴリー Weather station

Technoline WS 1600のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- WS 1600の取扱説明書
- Technolineの製品カード
- パンフレット
- またはTechnoline WS 1600の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Technoline WS 1600の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Technoline WS 1600の取り付け説明書、サービスマニュアル、簡易説明書、またはTechnoline WS 1600のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Technoline WS 1600の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Technoline WS 1600デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTechnoline WS 1600を使用するのを助ける技術的文書のことです。説明書は通常、全てのTechnoline WS 1600ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Technolineの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Technoline WS 1600の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTechnoline WS 1600の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Technoline WS 1600に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Technoline WS 1600デバイスの基本機能を使うにあたってのヒント。 Technoline WS 1600のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Technoline WS 1600に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTechnoline WS 1600のメーカー/サービスへの連絡先に関する情報。

Technoline WS 1600についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTechnoline WS 1600の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTechnoline WS 1600で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)