Toshiba 1500 Plusの取扱説明書

31ページ 0.76 mb
ダウンロード

ページに移動 of 31

Summary
  • Toshiba 1500 Plus - page 1

    TOSHIBA UNINTERRUPTIBLE POWER SYSTEM SINGLE PHASE - .6/.8/1.0 kVA 220V August, 1998 Part # 48449-000 MANUF A CTURED IN THE U .S.A. OPERA TION MANU AL 1500 1500 1500 1500 1500 and 1500 PLUS SERIES ...

  • Toshiba 1500 Plus - page 2

    TOSHIBA ...

  • Toshiba 1500 Plus - page 3

    TOSHIBA The instructions contained in this manual are not intended to cover all of the details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently f ...

  • Toshiba 1500 Plus - page 4

    TOSHIBA CONTENTS SECTION PAGE Disclaimer .................................................................................................. i Contents .................................................................................................. ii-iii Introduction ................................................................................ ...

  • Toshiba 1500 Plus - page 5

    TOSHIBA CONTENTS (Cont'd) SECTION PAGE 5.0 Operating the UPS (cont'd) ..................................................................... 5-1 5.3 Operation Monitoring ...................................................................... 5-3 5.3.1 Visual Indicator Functions ...................................................... 5-3 5.3. ...

  • Toshiba 1500 Plus - page 6

    TOSHIBA iv INTRODUCTION Thank you f or purchasing the 1500/1500 Plus Ser ies UPS. This Series features the v er y latest state of the art microprocessor technology and also uses IGBT transistors for fast, high power and lo w noise PWM (pulse width modulation) s witching. Also, the Plus Series f eatures a low impedance transformer to provide isolati ...

  • Toshiba 1500 Plus - page 7

    TOSHIBA v GENERAL SAFETY INSTRUCTIONS W ar nings in this manual appear in any of f our wa ys: 1) Danger - The danger symbol is a lightning bolt mark enclosed in a tr iangle which precedes the 3/16" high letters spelling the word "D ANGER". The danger symbol is used to indicate imminently hazardous situations, locations, and condition ...

  • Toshiba 1500 Plus - page 8

    TOSHIBA SA VE THESE INSTR UCTIONS- This manual contains impor tant instr uctions that should be followed during the installation and maintenance of the UPS and it's batteries. Use for models UE1E1E006-5M, UE1E1E008-5M, UE1E1E010-5M. - The maximum ambient temperature in which this UPS unit should be operated or stored is 104 ° F (40 ° C). - T ...

  • Toshiba 1500 Plus - page 9

    TOSHIBA IMPOR T ANT SAFETY INSTRUCTIONS Installation and servicing of batteries should be performed by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from the batteries. Proper maintenance to the battery system of this unit must be done by a qualified service technician, this is essential to the ...

  • Toshiba 1500 Plus - page 10

    TOSHIBA Model Capacity Manufacturer T y pe Quantity 600 VA Y uasa NPH5-12FR 5 800 VA 1000 VA Yuasa NPH5-12FR 5 viii © Copyright 1994 INSTR UCTIONS IMPOR T ANTES CONCERNANT LA SÉCURITÉ Cette notice contient des instructions importantes concernant la sécurité. Une battery peut présenter un risque de choc électrique, de brûlure par transfert d ...

  • Toshiba 1500 Plus - page 11

    TOSHIBA 1.0 Product Description 1.1 Theory of Operation An uninterruptible power supply is a system that is installed between the commercial pow er and the load equipment. It is used during shor t-term blac k outs or brownouts. The UPS provides steady ac output power during these commercial power interruptions. This power is provided for a long eno ...

  • Toshiba 1500 Plus - page 12

    TOSHIBA 2.0 Inspection/Storage/Disposal 2.1 Inspection of the new UPS equipment Upon receipt of the UPS, a careful inspection for shipping damage should be made. After Uncrating: 1) Check the unit for loose, broken, bent or otherwise damaged parts. If damage has occurred during shipment, keep all original crating and packing materials f or return t ...

  • Toshiba 1500 Plus - page 13

    TOSHIBA 3 - 1 3.0 Precautions 3.1 Installation Precautions (General) 1) Install the unit in a well ventilated location; allow at least 10 cm (4 inches) on all sides for air ventilation and for maintenance. 2) Install the unit in a stable, level, and upright position which is free of vibration. 3) Install the unit where the ambient temperature is wi ...

  • Toshiba 1500 Plus - page 14

    TOSHIBA 3. 0 Precautions 3.2 Prestart Precautions 1) Before connecting the UPS to a power source; move the operation switch (ST OP/R UN), on the front panel (See sections 9.1), to the STOP position. 3.3 Operating Precautions 1) The UPS should not be powered up until the entire operation manual has been reviewed. 2) The input power source voltage an ...

  • Toshiba 1500 Plus - page 15

    TOSHIBA 4 - 1 4 .1 Standard Series Specifications 4.0 Specifications MODEL NUMBER UE1E1E008-5M UE1E1E010-5M CAPACITY 800 VA (0.56 kW) 1000 VA (0.7 kW) Input Input voltage Single phase, 220 Vac, +10% to -30% (*) Input frequency 45 to 65 Hz Input capacity 800 VA 1000 VA Input power factor Approximate unity (0.95 to 1.0) B a t t e r y Battery rated vo ...

  • Toshiba 1500 Plus - page 16

    TOSHIBA MODEL NUMBER UE1E1E006-5M CAPACITY 600 VA (0.42 kW) Input Input voltage Single phase, 220 Vac, +10% to -30% (*) Input frequency 45 to 6 5 Hz Input capacity 600VA Input power factor Approximate unity (0.95 to 1.0) Ba tt e ry Battery rated voltage 60 Vdc Battery backup time when fully charged 12 min. at full load (**) with 0.7 power factor at ...

  • Toshiba 1500 Plus - page 17

    TOSHIBA 5 . 0 Operating the UPS 5.1 Operation Modes 5.1.1 AC Input Mode (normal operation) Power flow in AC input mode The above illustration shows circuit power flow in the ac input mode. The UPS unit's rectifier, included in a boost chopper circuit, converts ac input power to dc power. This dc power runs the unit's transistor inverter a ...

  • Toshiba 1500 Plus - page 18

    TOSHIBA 5 . 0 Operating the UPS 5.1 Operation Modes 5.1.3 Circuit-bypass mode Power flow in circuit-bypass mode. If the UPS unit is severely overloaded or develops an internal fault, the power flow is automatically switched from the unit's main circuit to the bypass circuit mode. P ower flo w through the bypass is sho wn in the abov e illustra ...

  • Toshiba 1500 Plus - page 19

    TOSHIBA 5 . 0 Operating the UPS 5.3 Operation Monitoring 5.3.1 Visual Indicator Functions The following LED (light emitting diode) indicators are located on the front panel (see Section 9.2 "Panel Layout"). Refer to these lamps for visual information about the operating condition of the UPS (see Section 5.3.3 "Visual and A udib le In ...

  • Toshiba 1500 Plus - page 20

    TOSHIBA Output Disp lay Stat us Explanation During battery backup all green lamps flash and the red Backup lamp is lit continuously . As the batteries discharge, the Battery green lamps extinguish Backup from top to bottom to indicate remaining battery capacity (This sample display shows battery voltage between 75% and 90% of battery capacity). All ...

  • Toshiba 1500 Plus - page 21

    TOSHIBA 5 - 5 5 . 0 Operating the UPS (Cont'd) 5.6 Battery Recharging The graph below shows the typical voltage requirements for recharging the UPS unit's batteries. Model Vmax. Vmin. Charge 600 VA 68.2 48.0 0. 4 ( A ) 800 VA 68.2 48.0 0. 4 ( A ) 1000 VA 68.2 48.0 0. 4 ( A ) Rated battery voltages Period 1 Period 2 Period 3 Time Current V ...

  • Toshiba 1500 Plus - page 22

    TOSHIBA 5 - 6 5 . 0 Operating the UPS 5.7 Battery Bac kup Time The UPS unit's batteries provide about 5-12 minutes of back-up time depending on the capacity of the UPS. These times are valid when a unit is operating under full load. When the units are operating at half load, the batteries can power the load equipment about 3 times longer . The ...

  • Toshiba 1500 Plus - page 23

    TOSHIBA 6 - 1 6 . 0 UPS Control Interface 6.1 DB25 Connector Pinout RS-232C serial communication and Dry Contacts are both standard features available through a DB25 female connector located on the back panel of the UPS (see Section 9.1). The RS-232C serial communication interface allows control of the UPS from a personal computer running special T ...

  • Toshiba 1500 Plus - page 24

    TOSHIBA 6 . 0 UPS Control Interface 6.2 RS-232C Serial Communication Interface The available data from the UPS, via RS-232C communication, is shown below: Output voltage Output current Operating conditions Battery voltage Input frequency Output frequency Utility power OK Low battery voltage detected UPS operating status UPS in BYP ASS mode (describ ...

  • Toshiba 1500 Plus - page 25

    TOSHIBA Fault Display status Probable cause Corre ctiv e act ion Remove cause of Output low Inverter fault or short short circuit. If none is volta ge circuit in UPS output found, contact your T oshiba service representative. Output Resonance with load Remove load overvoltage equipment equipment one piece at a time. DC Chopper fault Contact your T ...

  • Toshiba 1500 Plus - page 26

    TOSHIBA Fault Display status Probable cause Corre ctiv e act ion DC Inverter fault overcurrent DC Chopper fault overvoltage Contact y our T oshiba service representative. Input Chopper fault overcurrent UPS system T roub le with the control error PWB 7 - 2 7. 0 T roub leshooting Procedures 7.2 Fatal Fault Mode Fatal faults may or may not cause the ...

  • Toshiba 1500 Plus - page 27

    TOSHIBA 8 . 0 Preventive and Scheduled Maintenance/Parts Replacement 8.1 Preventive Maintenance T oshiba's 1500 and 1500 Plus Ser ies of uninterruptible pow er systems ha v e been designed to provide years of trouble-free operation requiring a minimum of preventive maintenance. The best preventive measure that the UPS user can take is to keep ...

  • Toshiba 1500 Plus - page 28

    TOSHIBA Fuse rating Model Amp rating Fuse model no. 600 VA 15.0A Bussmann MDL-8 800 VA 15.0A Bussmann MDL-8 1000 VA 15.0A Bussmann MDL-8 8 . 0 Preventive and Scheduled Maintenance/Parts Replacement 8.3 Fuse Rating Chart The following chart shows the recommended fuses for all UPS sizes. 8 - 2 ...

  • Toshiba 1500 Plus - page 29

    TOSHIBA 30% 45% 60% 75% 90% Overload +- X On Line AC Input Fault Replace Battery Backup X 1500 SERIES 1000VA ON-LINE UPS 8.00 10.00 Input power cord connector Fuse Computer Interface Connector Output Receptacles Air V ents 20.38 9 . 0 External Dimensions/Shipping Weights/Panel Layout 9.1 External Dimensions Front View Rear View Side Vie w Run/Stop ...

  • Toshiba 1500 Plus - page 30

    TOSHIBA 9 . 0 External Dimensions/Shipping Weights/Panel Layout 9.2 Panel Layout 9.3 Shipping W eights UPS Shipping W eight Model Pounds Kilograms 600 V A 48.8 22.2 800 V A 48.8 22.2 1000 V A 52.2 23.7 9 - 2 ...

  • Toshiba 1500 Plus - page 31

    TOSHIBA TOSHIBA INTERNATIONAL CORPORATION INDUSTRIAL DIVISION 13131 West Little Y ork Rd., Houston T e xas 77041 T el: [800] 231-1412 F ax: [713] 466-8773 T elex: 762078 Printed in U.S.A. ...

メーカー Toshiba カテゴリー Power Supply

Toshiba 1500 Plusのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1500 Plusの取扱説明書
- Toshibaの製品カード
- パンフレット
- またはToshiba 1500 Plusの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Toshiba 1500 Plusの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Toshiba 1500 Plusの取り付け説明書、サービスマニュアル、簡易説明書、またはToshiba 1500 Plusのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Toshiba 1500 Plusの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Toshiba 1500 Plusデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがToshiba 1500 Plusを使用するのを助ける技術的文書のことです。説明書は通常、全てのToshiba 1500 Plusユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Toshibaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Toshiba 1500 Plusの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははToshiba 1500 Plusの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Toshiba 1500 Plusに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Toshiba 1500 Plusデバイスの基本機能を使うにあたってのヒント。 Toshiba 1500 Plusのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Toshiba 1500 Plusに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるToshiba 1500 Plusのメーカー/サービスへの連絡先に関する情報。

Toshiba 1500 Plusについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもToshiba 1500 Plusの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがToshiba 1500 Plusで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)