  • Omega Engineering DPG10L - page 1

    DPG10L LARGE DISPLA Y PRESSURE GAUGE M3367/0606 User’ s Guide http://www .omega.com e-mail: info@omega.com ...

  • Omega Engineering DPG10L - page 2

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OMEGA...Of Course! TEMPERA TURE ✓ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies ✓ W ire: Thermocouple, R TD & Thermistor ✓ Calibrators & Ice Point References ✓ Recorders, Controllers & Process Monitors ✓ Infrared Pyromet ...

  • Omega Engineering DPG10L - page 3

    T able of Contents W arranty/Disclaimer ........................................................................2 Return Requests/Inquiries ................................................................3 Instructions ......................................................................................4 T o Zer o or “T ARE OUT” an existing of ...

  • Omega Engineering DPG10L - page 4

    • W arranty/Disclaimer OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’ s W arranty adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OMEGA ’ s cu ...

  • Omega Engineering DPG10L - page 5

    • Return Requests/Inquiries Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBT AIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA ’S CUSTOMER SER VICE DEP AR TMENT (IN ORDER T O A VOID PROCESSING DELA YS). The assigned AR number should then be mar ...

  • Omega Engineering DPG10L - page 6

    • Instructions The model DPG10L Digital Pressure Gauge has several features not normally found as standard in Digital Pressure Gauges. These include the Analog Scale, T are, and Peak Holds. The Analog Scale is a 40 segment display that appears around the edge of the liquid crystal display . This scale represents the pressure reading as a percenta ...

  • Omega Engineering DPG10L - page 7

    2.3 T o disengage Hold press and hold the “MODE” key until the reading starts flashing. Release the “MODE” key then press the “MODE” key once more, the display will read “HOLD”. Press the “ENTR” key , the display will read “NO H” Press the “ENTR” key once more and the display will return to reading the system pressure. ...

  • Omega Engineering DPG10L - page 8

    3.5 The alarm set point indicator segment of the bar graph will “blink” when that set point is activated. The hookup of optional outputs is covered later in this manual 4.0 Zero T rimming 4.1 Should it be necessary to readjust the Zero setting, an adjustment has been provided. Prior to adjusting the zero, verify that you are displaying the “g ...

  • Omega Engineering DPG10L - page 9

    • DPG10L Output Options Several output signals are available on the circular 6 pin connector located on the rear of the unit. Depending on the option selected the signals are present on pins as follows. DPG10L Pin Out T able A B C D E F PG-10000 Pin Out Table 4-20 mA with Alarm + Excitation – Excitation Dig Gnd Alarm 2 Alarm 1 Gnd 0-5 VDC + Exc ...

  • Omega Engineering DPG10L - page 10

    • Wiring A B C D – EXCITATION + EXCITATION Gauge Connector Typical 4-20 mA Circuit 4-20 mA CURRENT LOOP E F – EXCITATION + EXCITATION Gauge Connector Typical 0-5 VDC Circuit + SUPPLY VOLTAGE + OUTPUT – OUTPUT Typical 4-20 mA Circuit with Open Collector Alarms R = 250 ohm for 1-5 V output L R = 500 ohm for 2-10 V output L DO NOT EXCEED 750 O ...

  • Omega Engineering DPG10L - page 11

    OMEGA ’ s policy is to make running changes, not model changes, whenever an improvement is possible. This af fords our customers the latest in technology and engineering. It is the policy of OMEGA to comply with all worldwide safety and EMC/ EMI regulations that apply . OMEGA is constantly pursuing certification of its products to the European N ...

  • Omega Engineering DPG10L - page 12

    OMEGAnet ® On-Line Service Internet e-mail www .omega.com info@omega.com Servicing Nor th America: USA: One Omega Drive, P .O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.ca ...

メーカー Omega Engineering カテゴリー Marine Instruments

Omega Engineering DPG10Lのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DPG10Lの取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering DPG10Lの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering DPG10Lの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering DPG10Lの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering DPG10Lのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering DPG10Lの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering DPG10Lデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering DPG10Lを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering DPG10Lユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering DPG10Lの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering DPG10Lの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering DPG10Lに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering DPG10Lデバイスの基本機能を使うにあたってのヒント。 Omega Engineering DPG10Lのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering DPG10Lに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering DPG10Lのメーカー/サービスへの連絡先に関する情報。

Omega Engineering DPG10Lについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering DPG10Lの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering DPG10Lで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)