Lincoln Electric SVM134-Aの取扱説明書

97ページ 1.24 mb
ダウンロード

ページに移動 of 97

Summary
  • Lincoln Electric SVM134-A - page 1

    CLA SSIC I SVM134-A October , 2000 For use with machine code numbers 10068 to 10069 TM RETURN TO MAIN INDEX SER VICE MANUAL Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO ...

  • Lincoln Electric SVM134-A - page 2

    SAFETY i i CLASSIC I FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b . Operate engines in open, well-v entilated areas or vent the engine e xhaust fumes outdoors. _______________________ ...

  • Lincoln Electric SVM134-A - page 3

    SAFETY ii ii CLASSIC I ARC RA YS can burn. 4.a. Use a shield with the proper filter and cov er plates to protect your e yes from sparks and the ra ys of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b . Use suitab le clothing made from durable flame-resistant material to pr ...

  • Lincoln Electric SVM134-A - page 4

    CLASSIC I FOR ELECTRICALL Y powered equipment. 8.a. T ur n off input power using the disconnect switch at the fuse bo x before working on the equipment. 8.b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manuf acturer’ s recommendations. 8.c. Ground the equipment in accordance with the U.S . Nati ...

  • Lincoln Electric SVM134-A - page 5

    SAFETY iv iv CLASSIC I PRÉCA UTIONS DE SÛRETÉ P our votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté P our Soudage A L ’Arc 1. Protegez-vous contre la secousse électrique: a. ...

  • Lincoln Electric SVM134-A - page 6

    MASTER T ABLE OF CONTENTS FOR ALL SECTIONS v v CLASSIC I P age Safety .................................................................................................................................................i-iv Installation ..................................................................................................................... ...

  • Lincoln Electric SVM134-A - page 7

    T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 CLASSIC I Installation T echnical Specifications ..............................................................................................................A-2 Saf ety Precautions ................................................................................................. ...

  • Lincoln Electric SVM134-A - page 8

    INST ALLA TION A-2 A-2 CLASSIC I TECHNICAL SPECIFICA TIONS - CLASSIC I INPUT - DIESEL ENGINE Manufacturer Description Speed Displacement Ignition Capacities Continental 4 cyl., 4 cycle 1450 RPM 164.7 cu. in. Distributor Fuel: 15 gal. TM27 W ater-cooled Full load (2700 cc) T ype (57 liters) gasoline Electronic 38 HP @ 1600 RPM Oil: 6.0 qt. 1450 RPM ...

  • Lincoln Electric SVM134-A - page 9

    Read this entire installation section before y ou start installation. SAFETY PRECA UTIONS Do not attempt to use this equipment until you ha ve thoroughly read all the operation and maintenance manuals supplied with y our machine. They include impor tant saf ety precautions; detailed engine star ting, operating, and maintenance instructions; and par ...

  • Lincoln Electric SVM134-A - page 10

    ST A CKING Classic I machines CANNO T be stacked. TIL TING Place the machine on a secure, le vel surf ace whene v- er you use it or store it. Any surf aces you place it on other than the ground must be firm, non-skid, and structurally sound. The gasoline engine is designed to run in a lev el posi- tion f or best performance. If you do operate it at ...

  • Lincoln Electric SVM134-A - page 11

    COOLING SYSTEM The cooling system has been filled at the f actory with a 50-50 mixture of eth ylene glycol antifreeze and w ater . Check the r adiator le v el and add a 50-50 solution as needed. (See the engine manual or antifreez e con- tainer f or alternate antifreeze recommendations.) MUFFLER This welder is supplied with an adjustab le rain cap ...

  • Lincoln Electric SVM134-A - page 12

    MA CHINE GROUNDING According to the United States National Electrical Code, the fr ame of this por table gener ator is not required to be grounded and is permitted to ser v e as the grounding means f or cord connected equipment plugged into its receptacle. When the Classic I is mounted on a truck or a trailer , the machine generator ground stud MUS ...

  • Lincoln Electric SVM134-A - page 13

    ELECTRICAL OUTPUT CONNECTIONS See Figure A.2 f or the location of the 115V DC v olt receptacle, weld output terminals, and ground stud. WELDING CABLE CONNECTIONS CABLE INST ALLA TION AND CABLE SIZES With the engine off , route the electrode and work cables through the str ain relief brac ket on the base and connect to the terminals located below th ...

  • Lincoln Electric SVM134-A - page 14

    NO TES A-8 A-8 CLASSIC I Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM134-A - page 15

    Section B-1 Section B-1 CLASSIC I T ABLE OF CONTENTS - OPERA TION SECTION - Operation ............................................................................................................................... Section B Saf ety Instructions ......................................................................................................... ...

  • Lincoln Electric SVM134-A - page 16

    OPERA TING INSTR UCTIONS Read and understand this entire section bef ore operat- ing your Classic I. SAFETY INSTR UCTIONS Do not attempt to use this equipment until you ha ve thoroughly read all the operation and maintenance manuals supplied with y our machine. They include impor tant saf ety precautions; detailed engine star ting, operating, and m ...

  • Lincoln Electric SVM134-A - page 17

    RECOMMENDED APPLICA TIONS WELDER The Classic I provides e xcellent constant current DC welding output f or stic k (SMA W) welding and for DC TIG welding. For more details on using the machine as a welder , see W elding Operation in the Operation section of this manual. GENERA T OR The Classic I is also capable of pro viding 1.75 kw of 115V DC auxil ...

  • Lincoln Electric SVM134-A - page 18

    OPERA TION B-4 B-4 CLASSIC I FIGURE B.1 – OUTPUT CONTROLS 1. CURRENT RANGE SELECTOR 2. FINE CURRENT ADJUSTMENT 3. 115 V OL T DC RECEPT ACLE 4. WELD OUTPUT TERMINAL (–) 5. WELD OUTPUT TERMINAL (+) 6. GROUND STUD WELDER/GENERA T OR CONTR OLS See Figure B.1 f or the location of the f ollo wing features: 1. CURRENT RANGE SELECT OR: Selects ranges o ...

  • Lincoln Electric SVM134-A - page 19

    CONTROL OF WELDING CURRENT • DO NOT turn the CURRENT RANGE SELECT OR while welding because the current ma y arc between the contacts and damage the s witch. • DO NO T attempt to set the CURRENT RANGE SELECT OR between the fiv e points designated on the nameplate. See Figure B.2. The CURRENT RANGE SELECT OR provides fiv e o verlapping current ra ...

  • Lincoln Electric SVM134-A - page 20

    GASOLINE ENGINE CONTROLS See Figure B.3 f or the location of the f ollowing f eatures: 1. IDLER CONTROL T OGGLE SWITCH: Adjusts the running speed of the engine. The s witch has two positions, "HIGH" and "A UT O ." In "HIGH," the engine runs continuously at high idle. In "A UT O," the idler control works as f ...

  • Lincoln Electric SVM134-A - page 21

    ENGINE OPERA TION DO NO T R UN THE ENGINE A T EXCESSIVE SPEEDS. The maximum allo wab le high idle speed for the Classic I is 1550 RPM, no load. Do NO T increase the idle speed on the engine. Se v ere personal injur y and damage to the machine can result if it is operated at speeds abov e the maximum r ated speed. Read and understand all saf ety ins ...

  • Lincoln Electric SVM134-A - page 22

    ST OPPING THE ENGINE 1. Remove all w elding and generator po wer loads and let the engine cool by running it f or se v eral minutes at lo w idle. 2. Place the IGNITION switch in the OFF position. The engine controls were properly set at the factory and should require no adjusting when receiv ed. At the end of each da y’ s welding, refill the fuel ...

  • Lincoln Electric SVM134-A - page 23

    WELDING OPERA TION T O USE THE CLASSIC I FOR DC CONST ANT CURRENT STICK OR TIG WELDING: 1. Remove the flange n uts from the weld output ter- minals and place the work and electrode welding cables o v er the terminals. For positiv e electrode, connect the electrode cable to the + terminal and the work cable to –. F or negativ e electrode, re v ers ...

  • Lincoln Electric SVM134-A - page 24

    OPERA TION B-10 B-10 CLASSIC I T ABLE B.1 RANGE SETTINGS FOR WIRE SIZE/SPEED Diameter (inches) Wire Speed Range Appropriate Curr ent Range (inches/minute) .035 80-110 75 to 120 Amps .045 70-130 120 to 170 Amps .068 40-90 125 to 210 Amps T O USE THE CLASSIC I FOR DC WIRE FEED WELDING (CONST ANT V OL T A GE) WITH WIRE FEED MODULE: 1. Connect the LN-2 ...

  • Lincoln Electric SVM134-A - page 25

    T ABLE OF CONTENTS - A CCESSORIES - Accessories ........................................................................................................................... Section C Options/Accessories ...................................................................................................................C-2 Semiautomatic W elding Access ...

  • Lincoln Electric SVM134-A - page 26

    OPTIONS/A CCESSORIES The f ollowing options/accessories are av ailable f or your Classic I from your local Lincoln Distrib utor . T railer (K768) - For in-plant or y ard towing at speeds under 10 m.p .h. Not intended f or highwa y towing. T railer (K780) - T wo-wheeled trailer with brak es, lights, and f enders. F or highwa y use, consult applicabl ...

  • Lincoln Electric SVM134-A - page 27

    The Lincoln Electric LN-25 wire feeder is r ecommend- ed for wire feed welding with the Classic I. CONNECTION OF THE LN-25 T O THE CLASSIC I “A CROSS THE ARC” WITH WIRE FEED MODULE (SEE FIGURE C.1.) 1. Shut the welder off. 2. Connect the electrode cable fr om the LN-25 to the “+” terminal of the welder . Connect the work cable to the “CV? ...

  • Lincoln Electric SVM134-A - page 28

    NO TES C-4 C-4 CLASSIC I Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM134-A - page 29

    Section D-1 Section D-1 CLASSIC I T ABLE OF CONTENTS -MAINTENANCE- Maintenance ......................................................................................................................... Section D Saf ety Precautions ......................................................................................................................D ...

  • Lincoln Electric SVM134-A - page 30

    SAFETY PRECA UTIONS • Ha ve qualified personnel do all maintenance and troubleshooting w ork. • T ur n the engine off before w orking inside the machine. • Remov e cov ers or guards only when necessar y to perf orm maintenance and replace them when the maintenance requiring their remov al is complete. • If covers or guards are missing from ...

  • Lincoln Electric SVM134-A - page 31

    CHANGE THE OIL: Change the oil, while the engine is still warm, as follo ws: 1 . Drain the oil from the dr ain plug located on the engine bottom, as shown in Figure D .1. 2. Replace the plug and tighten it securely . 3. Remove the oil fill cap and add oil until the le vel reaches the upper dash full mark on the dipstick. Use high quality oil viscos ...

  • Lincoln Electric SVM134-A - page 32

    FUEL FIL TER: Inspect the in-line fuel filter daily . When necessar y remo v e the sediment bo wl from beneath the gas tank and clean out any accum ulated dir t and water . Change the fuel filter after the first 50 hours of opera- tion and e v er y 500 hours thereafter . AIR CLEANER: The Continental engine is equipped with a dr y type air filter . ...

  • Lincoln Electric SVM134-A - page 33

    F AN BEL T : Fan belts tend to loosen after the first 50 hours of operation. If the fan belt is loose, the engine can overheat and the battery can lose its charge. Check belt tightness by pressing on the belt midway between the pulleys. The belt should deflect no more than 13 mm (0.5 in.). See Figure D.3. T o adjust the fan belt, loosen the alterna ...

  • Lincoln Electric SVM134-A - page 34

    B A TTER Y MAINTENANCE GASES FROM BA TTER Y can e xplode. • K eep sparks, flame , and cigarettes a way from batter y . BA TTER Y ACID can b urn eyes and skin. • Wear glo ves and e ye protection and be careful when working near a batter y . F ollow the instructions printed on the batter y . T o pre v ent EXPLOSION when: • INST ALLING A NEW BA ...

  • Lincoln Electric SVM134-A - page 35

    WELDER/GENERA T OR MAINTENANCE ST ORA GE: Store the Classic I in clean, dr y , protected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air . Do this at least once a week in par ticularly dir ty areas. NAMEPLA TES : Whene v er routine maintenance is per- f ormed on this machine - or at least yearly - inspect a ...

  • Lincoln Electric SVM134-A - page 36

    CURRENT RANGE SELECT OR CONT ACTS: The contacts should not be greased. T o keep the contacts clean, rotate the current control handle through its entire range frequently . Good practice is to tur n the handle from maximum to minimum setting twice each morning before star ting to weld. Nev er rotate the han- dle while the machine is under load. Put ...

  • Lincoln Electric SVM134-A - page 37

    MAINTENANCE D-9 D-9 CLASSIC I FIGURE D .5 - MAJOR COMPONENT LOCA TIONS 11 12 9 8 15 14 16 13 7 6 5 3 4 2 1 10 1. RIGHT CASE SIDE (DOOR) 2. BASE (WITH BA TTER Y) 3. EXCITER BRUSHES 4. EXCITER 5. GENERA TOR 6. GENERA TOR BR USHES 7. OUTPUT TERMINALS 8. FUEL T ANK 9. CASE FRONT WITH CONTROL P ANEL 10. LEFT CASE SIDE 11. CASE TOP 12. CASE BACK 13. RADI ...

  • Lincoln Electric SVM134-A - page 38

    NO TES D-10 D-10 CLASSIC I Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM134-A - page 39

    Section E-1 Section E-1 CLASSIC I Theory of Operation ............................................................................................................. Section E General Description ...............................................................................................................E-2 Batter y , Star ter , Engine Alternator a ...

  • Lincoln Electric SVM134-A - page 40

    GENERAL DESCRIPTION The Classic I is a heavy duty , engine driven, DC arc welding pow er source capable of pro viding constant current output f or stick w elding or DC TIG welding. Also , a total of 1750 watts of auxiliary power is a v ailable at the 115VDC receptacle. The Classic I is manuf ac- tured with all copper windings. B A TTER Y , ST AR TE ...

  • Lincoln Electric SVM134-A - page 41

    ENGINE, MAIN GENERA T OR ARMA TURE AND FRAME AND DC EXCITER EXCIT A TION (FLASHING) The main generator armature and the exciter arma- ture are mechanically coupled to the engine. When the engine is star ted and running, the residual mag- netism that is stored in the e xciter pole pieces is induced upon the e xciter armature. This causes the e xcite ...

  • Lincoln Electric SVM134-A - page 42

    ENGINE, MAIN GENERA TOR ARMA TURE AND FRAME AND DC EXCITER (CONTINUED) CURRENT RANGE SELECTOR The selector switch acts as a course current adjust- ment by allowing varying amounts of series windings to be included in the welding current path. The series coils and selector switch are connected in series with the negative output terminal. FINE CURREN ...

  • Lincoln Electric SVM134-A - page 43

    DC GENERA TOR MACHINES The armature winding of a DC generator is located on the rotating member . Current is conducted from it by means of carbon brushes. The field winding is located in the stator , which is stationary and excited by direct current. The armature coil sides are placed at opposite points on the rotating shaft with the conductors par ...

  • Lincoln Electric SVM134-A - page 44

    NO TES E-6 E-6 CLASSIC I Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM134-A - page 45

    Section F-1 Section F-1 CLASSIC I T roubleshooting & Repair Section ................................................................................. Section F How to Use T roubleshooting Guide .......................................................................................F-2 PC Board T roubleshooting Procedures ........................ ...

  • Lincoln Electric SVM134-A - page 46

    HOW T O USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty . For your safety and to avoid Electrical Shock, please observe all safet ...

  • Lincoln Electric SVM134-A - page 47

    ELECTRIC SHOCK can kill. Hav e an electr ician install and service this equipment. T ur n the machine OFF bef ore working on equipment. Do not touch electrically hot par ts. Sometimes machine f ailures appear to be due to PC board f ailures. These problems can sometimes be traced to poor electrical connections. T o a v oid prob- lems when troublesh ...

  • Lincoln Electric SVM134-A - page 48

    TROUBLESHOOTING & REP AIR F-4 F-4 CLASSIC I Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance b ...

  • Lincoln Electric SVM134-A - page 49

    TROUBLESHOOTING & REP AIR F-5 F-5 CLASSIC I TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance b ...

  • Lincoln Electric SVM134-A - page 50

    TROUBLESHOOTING & REP AIR F-6 F-6 CLASSIC I Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance b ...

  • Lincoln Electric SVM134-A - page 51

    TROUBLESHOOTING & REP AIR F-7 F-7 CLASSIC I TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance b ...

  • Lincoln Electric SVM134-A - page 52

    TROUBLESHOOTING & REP AIR F-8 F-8 CLASSIC I Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance b ...

  • Lincoln Electric SVM134-A - page 53

    TROUBLESHOOTING & REP AIR F-9 F-9 CLASSIC I TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance b ...

  • Lincoln Electric SVM134-A - page 54

    TROUBLESHOOTING & REP AIR F-10 F-10 CLASSIC I Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance ...

  • Lincoln Electric SVM134-A - page 55

    TROUBLESHOOTING & REP AIR F-11 F-11 CLASSIC I TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance ...

  • Lincoln Electric SVM134-A - page 56

    F-12 F-12 CLASSIC I TROUBLESHOOTING & REP AIR TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely , con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance ...

  • Lincoln Electric SVM134-A - page 57

    TROUBLESHOOTING & REP AIR F-13 F-13 CLASSIC I DC EXCITER TEST W ARNING Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid ele ...

  • Lincoln Electric SVM134-A - page 58

    TR OUBLESHOO TING & REP AIR F-14 F-14 CLASSIC I SERIES COIL CONNECTION POINT (NEGA TIVE) POSITIVE FIGURE F .1 – 120VDC RECEPT ACLE DC EXCITER TEST (continued) TEST PROCEDURE 1. T urn off the engine and remov e all e xternal loads to the welder terminals and auxiliar y receptacle. MO VING P ARTS can injure. • Remov e guards only when necessa ...

  • Lincoln Electric SVM134-A - page 59

    TR OUBLESHOO TING & REP AIR F-15 F-15 CLASSIC I DC EXCITER TEST (continued) EXITER COVER WARRANTY CHECK VOLTAGE A T BRUSH HOLDERS HERE (RIGHT SIDE IS +) + FIGURE F .2 – EXCITER COVER REMOV AL 4. T urn off the engine. Using the 3/8” nut driver , remov e the e xciter cover . See Figure F .2. MO VING P ARTS can injure. • Remov e guards only ...

  • Lincoln Electric SVM134-A - page 60

    TR OUBLESHOO TING & REP AIR F-16 F-16 CLASSIC I WHITE FLEX LEAD SMALL FLEX LEAD SOLID LEAD WARRANTY FIGURE F .3 – BRUSH HOLDER LEADS Shunt Coil and Series Coil Resistance T ests 7. T ur n the engine OFF . 8. Using the 3/8" nut driver , disconnect the two leads from the left side brush holder . See Figure F .3. Separate the two leads. One ...

  • Lincoln Electric SVM134-A - page 61

    TROUBLESHOOTING & REP AIR F-17 F-17 CLASSIC I W ARNING IDLER SOLENOID TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid ...

  • Lincoln Electric SVM134-A - page 62

    TR OUBLESHOO TING & REP AIR F-18 F-18 CLASSIC I IDLER SOLENOID TEST (continued) FIGURE F .4 – IDLER SOLENOID CONNECTIONS QUICK CONNECT LEADS TEST PROCEDURE 1. T urn the engine OFF . 2. Unlatch and secure the right side door . 3. Locate the idler solenoid and the two leads with quick connects . See Figure F .4. 4. Disconnect the two solenoid l ...

  • Lincoln Electric SVM134-A - page 63

    TROUBLESHOOTING & REP AIR F-19 F-19 CLASSIC I W ARNING MAIN GENERA TOR SHUNT FIELD WINDING TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For you ...

  • Lincoln Electric SVM134-A - page 64

    TR OUBLESHOO TING & REP AIR F-20 F-20 CLASSIC I MAIN GENERA T OR SHUNT FIELD WINDING TEST (continued) FIGURE F .5 – PLUG P10 LOCA TION PLUG P10 TEST PROCEDURE 1. T urn the engine OFF . 2. Unlatch, lift and secure the right side door . 3. Locate plug P10. See Figure F .5. 4. Remov e plug P10. Return to Section TOC Return to Section TOC Return ...

  • Lincoln Electric SVM134-A - page 65

    TROUBLESHOOTING & REP AIR F-21 F-21 CLASSIC I MAIN GENERA TOR SHUNT FIELD WINDING TEST (continued) FIGURE F .6 – PLUG P10 PIN ASSIGNMENTS PIN 3 PIN 5 TA B 5. Locate the blue (U) (pin 3) and the brown (N) (pin 5) leads in the harness plug. See Figure F .6. 6. Using the volt/ohmmeter , measure the resis- tance between the blue and the brown lea ...

  • Lincoln Electric SVM134-A - page 66

    TROUBLESHOOTING & REP AIR F-22 F-22 CLASSIC I W ARNING ENGINE THROTTLE ADJUSTMENT TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety ...

  • Lincoln Electric SVM134-A - page 67

    TR OUBLESHOO TING & REP AIR F-23 F-23 CLASSIC I ENGINE THR O TTLE ADJUSTMENT TEST (continued) FIGURE F .7 – BLOWER P ADDLE MARK LOCA TION BLOWER P ADDLE MARK TEST PROCEDURE Strobe T ach Method 1. Conduct this procedure with the engine OFF . 2. Unlatch, lift, and secure the right and left side doors. 3. With the white or red marking pencil, pl ...

  • Lincoln Electric SVM134-A - page 68

    TR OUBLESHOO TING & REP AIR F-24 F-24 CLASSIC I ENGINE THR O TTLE ADJUSTMENT TEST (continued) Adjust High Idle a. Make sure there is no load on the machine . b . Set the Idler switch to the HIGH position. c. Locate the gov ernor on the left side of the engine. See Figure F .8. d. Using the 3/8” wrench to tur n the adjustment screw and loc kin ...

  • Lincoln Electric SVM134-A - page 69

    TR OUBLESHOO TING & REP AIR F-25 F-25 CLASSIC I ENGINE THR O TTLE ADJUSTMENT TEST (continued) FIGURE F .9 – LOW IDLE ADJUSTMENT SPEED ADJUSTMENT SCREW LOCKING NUT IDLER ROD Adjust Low Idle a. Make sure there is no load on the machine . b . Set the Idler switch to A UT O and w ait f or the engine to change to low idle speed. c. Check the align ...

  • Lincoln Electric SVM134-A - page 70

    TROUBLESHOOTING & REP AIR F-26 F-26 CLASSIC I W ARNING FLASHING THE FIELDS Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid ...

  • Lincoln Electric SVM134-A - page 71

    TR OUBLESHOO TING & REP AIR F-27 F-27 CLASSIC I FLASHING THE FIELDS (continued) FIGURE F .10 – EXCITER CO VER REMO V AL EXITER COVER PROCEDURE 1. T urn the engine OFF . 2. Using the 3/8” wrench, remov e the exciter cov er . See Figure F .10. Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Ma ...

  • Lincoln Electric SVM134-A - page 72

    TR OUBLESHOO TING & REP AIR F-28 F-28 CLASSIC I FLASHING THE FIELDS (continued) FIGURE F .11 - BRUSH HOLDER/B A TTER Y JUMPER CONNECTIONS + RAISE EXCITER BRUSH OFF COMMUT A T OR TO POSITIVE BA TTERY TERMINAL TO NEGATIVE BA TTERY TERMINAL WARRANTY 3. Raise one e xciter brush off the ar mature com- mutator . 4. Using the jumper leads and the 12VD ...

  • Lincoln Electric SVM134-A - page 73

    TR OUBLESHOO TING & REP AIR F-29 F-29 CLASSIC I This is the typical auxiliar y output v oltage generated from a properly operating machine . Note that each v er tical division represents 50 volts and that each horizontal division represents 2 milliseconds in time. Note: Scope probes connected at machine 115VDC receptacle. SCOPE SETTINGS V olts/ ...

  • Lincoln Electric SVM134-A - page 74

    TR OUBLESHOO TING & REP AIR F-30 F-30 CLASSIC I This is the typical DC welding output v oltage generated from a properly operating machine . Note that each v er tical division represents 50 volts and that each horizontal division represents 5 milliseconds in time. Note: Scope probes connected at machine output terminals. SCOPE SETTINGS V olts/D ...

  • Lincoln Electric SVM134-A - page 75

    TR OUBLESHOO TING & REP AIR F-31 F-31 CLASSIC I This is the typical DC welding output v oltage generated from a properly operating machine . Note that each v er tical division represents 20 volts and that each horizontal division represents 5 milliseconds in time. The machine was loaded with a resistance grid bank. Note: Scope probes connected ...

  • Lincoln Electric SVM134-A - page 76

    TROUBLESHOOTING & REP AIR F-32 F-32 CLASSIC I W ARNING DC EXCITER ARMA TURE AND FIELD COILS REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your facto ...

  • Lincoln Electric SVM134-A - page 77

    TR OUBLESHOO TING & REP AIR F-33 F-33 CLASSIC I DC EXCITER ARMA TURE AND FIELD COILS REMO V AL AND REPLA CEMENT (continued) FIGURE F .12 – EXCITER CO VER REMO V AL ARMA TURE BRUSH HOLDER ASSEMBL Y (2) EXITER FRAME POLE PIECE BOL TS (4) EXITER COVER ARMA TURE LOCKING NUT FLA T W ASHER SLEEVE COLLAR PROCEDURE DC Exciter Armature Remov al Pr oce ...

  • Lincoln Electric SVM134-A - page 78

    TR OUBLESHOO TING & REP AIR F-34 F-34 CLASSIC I DC EXCITER ARMA TURE AND FIELD COILS REMO V AL AND REPLA CEMENT (continued) Field Coils Remov al Pr ocedure 1. P erform the DC Exciter Armature Remov al Procedure. 2. Using the 3/8” wrench, remove the leads from the brush holder . Note lead placement f or reassembly . 3. Using the 1/2” wrench, ...

  • Lincoln Electric SVM134-A - page 79

    TROUBLESHOOTING & REP AIR F-35 F-35 CLASSIC I W ARNING MAIN GENERA TOR FRAME REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty . F ...

  • Lincoln Electric SVM134-A - page 80

    TR OUBLESHOO TING & REP AIR F-36 F-36 CLASSIC I MAIN GENERA T OR FRAME REMO V AL AND REPLA CEMENT (continued) FIGURE F .13 – BA TTER Y P ANEL REMOV AL NEGA TIVE BA TTERY CABLE PROCEDURE 1. T urn the engine OFF . 2. Using the 7/16” wrench, remov e the two bolts and washers and par tially slide out the battery mounting panel. See Figure F .13 ...

  • Lincoln Electric SVM134-A - page 81

    TR OUBLESHOO TING & REP AIR F-37 F-37 CLASSIC I MAIN GENERA T OR FRAME REMO V AL AND REPLA CEMENT (continued) FIGURE F .14 – TOP AND DOORS ASSEMBL Y DET AILS BOL T / NUT (4) 'L' DOOR HOOKS (4) 4. Using the 1/2” wrench, remove the f our nuts and bolts holding the case top and doors assembly to the w elder frame . Remove the rubber ...

  • Lincoln Electric SVM134-A - page 82

    TR OUBLESHOO TING & REP AIR F-38 F-38 CLASSIC I MAIN GENERA T OR FRAME REMO V AL AND REPLA CEMENT (continued) FIGURE F .15 – FUEL T ANK MOUNTING DET AILS BOL TS / NUTS / W ASHERS (4) FUEL T ANK FUEL BOWL RAILS FUEL LINE 5. P erform the DC Exciter Armature Remov al Procedure. 6. T urn off the fuel supply at the fuel bowl and remov e the fuel l ...

  • Lincoln Electric SVM134-A - page 83

    TR OUBLESHOO TING & REP AIR F-39 F-39 CLASSIC I FIGURE F .16 – SELECTOR SWITCH LEAD REMOV AL SELECTOR SWITCH TERMINAL LEAD (5) A C B D E 9. Using the 1/2” wrench, remove the fiv e heavy fle x leads from the selector s witch terminals. Label the leads f or reassembly . See Figure F .16. FIGURE F .17 – OUTPUT TERMINAL LEAD REMOV AL COPPER S ...

  • Lincoln Electric SVM134-A - page 84

    TR OUBLESHOO TING & REP AIR F-40 F-40 CLASSIC I FIGURE F .18 – CHOKE CONTROL CABLE REMOV AL LOOSEN HERE CHOKE CABLE 12. Using the slot head screw driv er , remove the choke control cab le from the engine carb ure- tor assembly . Mark cable replacement f or reassembly . See Figure F .18. MAIN GENERA T OR FRAME REMO V AL AND REPLA CEMENT (conti ...

  • Lincoln Electric SVM134-A - page 85

    TR OUBLESHOO TING & REP AIR F-41 F-41 CLASSIC I FIGURE F .19 – FRONT P ANEL WIRING CONNECTIONS A C B D E 15. SHUNT LEADS QUICK DISCONNECT 13. RED LEAD TO DC RECEPT ACLE 19. 20. BLUE AND BLACK LEADS TO AMMETER 17. RED LEADS TO IGNITION SWITCH 21. YELLOW LEAD TO IDLER SWITCH 22. BROWN LEAD TO IDLER SWITCH 16. "H" LEAD TO ST ART BUTTON ...

  • Lincoln Electric SVM134-A - page 86

    TR OUBLESHOO TING & REP AIR F-42 F-42 CLASSIC I FIGURE F .20 – FRONT P ANEL F ASTENER REMOV AL BOL TS / NUTS / W ASHERS (2) BASE MOUNTING BOL TS (4) MIDDLE SCREW (1) 23. Using the 1/2” wrench, remov e the two bolts , nuts, and w ashers that hold the front panel assembly to the horizontal r ails. (There is one on each side.) See Figure F .20 ...

  • Lincoln Electric SVM134-A - page 87

    TR OUBLESHOO TING & REP AIR F-43 F-43 CLASSIC I FIGURE F .21 – BRUSH BRACKET WRAP-AROUND COVER BRUSH BRACKET WRAP- AROUND COVER REMOVE (2) NUTS, W ASHERS, AND SCREWS 27. Using the slot head screw driv er , remove the two scre ws and nuts from the brush brack et wrap-around cov er . Remov e the cov er . See Figure F .21. MAIN GENERA T OR FRAME ...

  • Lincoln Electric SVM134-A - page 88

    TR OUBLESHOO TING & REP AIR F-44 F-44 CLASSIC I FIGURE F .23 – MAIN GENERA TOR FEET MOUNTING MAIN GENERA T OR REMOVE MOUNTING NUTS, WASHERS, AND BOL TS FEET (2) 30. Using the 3/4” wrench, remov e the frame mounting bolts, nuts , and w ashers from the f eet of the main generator . See Figure F .23. MAIN GENERA T OR FRAME REMO V AL AND REPLA ...

  • Lincoln Electric SVM134-A - page 89

    TR OUBLESHOO TING & REP AIR F-45 F-45 CLASSIC I 33. Using the rope sling and pr y bars, carefully lift and “wiggle” the gener ator frame a wa y from the engine and ar mature assembly . Be careful to suppor t the generator fr ame as you remov e it. NO TE: The exciter fr ame is also remov ed with the main generator frame . Reassembl y: Ref er ...

  • Lincoln Electric SVM134-A - page 90

    TR OUBLESHOO TING & REP AIR F-46 F-46 CLASSIC I W ARNING MAIN GENERA T OR ARMA TURE REMO V AL AND REPLA CEMENT Ser vice and repair should be perf or med b y only Lincoln Electric factory trained personnel. Unauthorized repairs perf ormed on this equipment may result in danger to the technician or machine operator and will in v alidate your f ac ...

  • Lincoln Electric SVM134-A - page 91

    TR OUBLESHOO TING & REP AIR F-47 F-47 CLASSIC I MAIN GENERA T OR ARMA TURE REMO V AL AND REPLA CEMENT (continued) FIGURE F .25 – MAIN GENERA TOR ARMA TURE MOUNTING MOUNTING BOL TS / LOCK W ASHERS (8) BLOWER P ADDLE SLING PROCEDURE 1. T urn the engine OFF . 2. P erform the DC Exciter Armature Remov al procedure. 3. P erf or m the Main Generato ...

  • Lincoln Electric SVM134-A - page 92

    TR OUBLESHOO TING & REP AIR F-48 F-48 CLASSIC I RETEST AFTER REP AIR Retest a machine: • If it is rejected under test for an y reason that requires y ou to remov e any mechanical par t which could aff ect the machine’ s electr ical characteristics. OR • If you repair or replace an y electrical components. ENGINE OUTPUT Mode No Load RPM Lo ...

  • Lincoln Electric SVM134-A - page 93

    ELECTRICAL DIAGRAMS G-1 G-1 CLASSIC I Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Electrical Diagrams Section .......................................................................................... Section G Wiring Diagram .................................................................................... ...

  • Lincoln Electric SVM134-A - page 94

    ELECTRICAL DIAGRAMS G-2 G-2 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-2 CLASSIC I WIRING DIAGRAM - CLASSIC I MOTOR + GROUND GROUND TO BASE TO ENGINE EXC ALTERNATOR S B + STARTING OIL PRESSURE SWITCH ...

  • Lincoln Electric SVM134-A - page 95

    ELECTRICAL DIAGRAMS G-3 CLASSIC I WIRING DIAGRAM - WIRE FEED MODULE 3-18-94 L9259 AMPHENOL 1 A D F 510 602 610A 503A 609 501 CONTACTOR CONTACTOR ++ + 622 666 633 75A 76 77 75 R501 630 631 CV CONTROL 4 667 634 J2 J3 501 631 600 608 610A 509 503A 630 503 J4 2 1 GND 31 32 609 610A 510 501 503A 602 75 76 77 2 4 J1 E G J 32 31 4A GND 2A 77B 76B 75A 76B ...

  • Lincoln Electric SVM134-A - page 96

    ELECTRICAL DIAGRAMS G-4 CLASSIC I SCHEMA TIC - IDLER PC BOARD EARTH GROUND CONNECTION M VOLTAGE NET FRAME CONNECTION 8 R- 20 NO. 10 COMMON CONNECTION TO SOLENOID LAST NO. USED TO BATTERY EQUIP. SUBJECT Y 16990 M B TO FRAME GND THRU MOUNTING SCREW GENERAL INFORMATION NONE (UNLESS OTHERWISE SPECIFIED) 2/10/93 ELECTRICAL SYMBOLS PER E1537 UNLESS OTHER ...

  • Lincoln Electric SVM134-A - page 97

    NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub ...

メーカー Lincoln Electric カテゴリー Welder

Lincoln Electric SVM134-Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SVM134-Aの取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric SVM134-Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric SVM134-Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric SVM134-Aの取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric SVM134-Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric SVM134-Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lincoln Electric SVM134-Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric SVM134-Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric SVM134-Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric SVM134-Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric SVM134-Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric SVM134-Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric SVM134-Aデバイスの基本機能を使うにあたってのヒント。 Lincoln Electric SVM134-Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric SVM134-Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric SVM134-Aのメーカー/サービスへの連絡先に関する情報。

Lincoln Electric SVM134-Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric SVM134-Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric SVM134-Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)