Mitsubishi Electronics NGMU-Eの取扱説明書

12ページ 0.36 mb
ダウンロード

ページに移動 of 12

Summary
  • Mitsubishi Electronics NGMU-E - page 1

    INST ALLA TION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. Air-Conditioners For Building Application INDOOR UNIT PCFY -P·NGMU- E ...

  • Mitsubishi Electronics NGMU-E - page 2

    2 s Before installing the unit, make sure you read all the “Safety precau- tions”. s Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system. Warning: Describes precautions that must be observed to prevent danger of injury or death to the user . Caution: Describes precautions th ...

  • Mitsubishi Electronics NGMU-E - page 3

    3 2. Installation location 3. Installing the indoor unit 3.1. Check the indoor unit accessories (Fig. 3-1) The indoor unit should be supplied with the following accessories (contained in the inside of the intake grille). Accessory name Q ’ ty 1 Washer 4 pcs 2 Pipe cover 1 pc Large size (For gas tubing) 3 Pipe cover 1 pc Small size (For liquid tub ...

  • Mitsubishi Electronics NGMU-E - page 4

    4 Fig. 3-8 Fig. 3-5 Fig. 3-6 Fig. 3-7 3.2.5. Indoor unit preparation (Fig. 3-5) 1. Install the suspending bolts. (Procure the W3/8 or M10 bolts locally .) Predetermine the length from the ceiling ( 1 within 100 mm). A Ceiling surface B Suspending bolt C Suspending bracket 2. Remove the intake grille. Slide the intake grille holding knobs (at two lo ...

  • Mitsubishi Electronics NGMU-E - page 5

    5 4. Installing the refrigerant piping 4.1. Precautions 4.1.1. For devices that use R22 refrigerant • Use the refrigeration oil applied to the flared sections. • Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, to connect the refrigerant pipes. Use refrigerant pipes with the thicknesses specified in the table to the belo ...

  • Mitsubishi Electronics NGMU-E - page 6

    6 Installing procedures (Fig. 5-2) 1. Attach the joint socket 5 supplied with the unit to the drain port on the unit with a vinyl chloride adhesive. 2. Fasten the socket cover 6 supplied with the unit to the joint socket 5 . 3. Attach the field drain tubing (VP20/O.D. ø 26 PVC TUBE) to the joint socket 5 with a vinyl chloride adhesive. 4. Wrap the ...

  • Mitsubishi Electronics NGMU-E - page 7

    7 6.2. Power supply wiring (Fig. 6-2) Power cable size (diameter) : more than 1.6 mm (A WG14) Ground cable size (diameter) : 1.6 mm (A WG14) * Use copper supply wires. * Use the electric wires over the rating voltage 300 V . [Selecting non-fuse breaker (NF) or earth leakage breaker (NV)] T o select NF or NV instead of a combination of Class B fuse ...

  • Mitsubishi Electronics NGMU-E - page 8

    8 6.4. Setting addresses (Fig. 6-6) (Be sure to operate with the main power turned OFF .) • There are two types of rotary switch setting available: setting addresses 1 to 9 and over 10, and setting branch numbers. 1 How to set addresses Example: If Address is “3”, remain SW12 (for over 10) at “0”, and match SW1 1(for 1 to 9) with “3”. ...

  • Mitsubishi Electronics NGMU-E - page 9

    9 6. Electrical work F A H C D E G I I I H B B-1. B-2. Fig. 6-8 A A B TB 6 B Fig. 6-7 J H Fig. 6-9 6.7. Remote controller 1) Installing procedures (1) Select an installing position for the remote controller . (Fig. 6-7) The temperature sensors are located on both remote controller and indoor unit. s Procure the following parts locally: T wo piece s ...

  • Mitsubishi Electronics NGMU-E - page 10

    ...

  • Mitsubishi Electronics NGMU-E - page 11

    ...

  • Mitsubishi Electronics NGMU-E - page 12

    Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment. HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN Printed in Japan BG79U668H01 ...

メーカー Mitsubishi Electronics カテゴリー Air Conditioner

Mitsubishi Electronics NGMU-Eのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- NGMU-Eの取扱説明書
- Mitsubishi Electronicsの製品カード
- パンフレット
- またはMitsubishi Electronics NGMU-Eの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mitsubishi Electronics NGMU-Eの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mitsubishi Electronics NGMU-Eの取り付け説明書、サービスマニュアル、簡易説明書、またはMitsubishi Electronics NGMU-Eのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mitsubishi Electronics NGMU-Eの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Mitsubishi Electronics NGMU-Eデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMitsubishi Electronics NGMU-Eを使用するのを助ける技術的文書のことです。説明書は通常、全てのMitsubishi Electronics NGMU-Eユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mitsubishi Electronicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mitsubishi Electronics NGMU-Eの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMitsubishi Electronics NGMU-Eの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mitsubishi Electronics NGMU-Eに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mitsubishi Electronics NGMU-Eデバイスの基本機能を使うにあたってのヒント。 Mitsubishi Electronics NGMU-Eのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mitsubishi Electronics NGMU-Eに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMitsubishi Electronics NGMU-Eのメーカー/サービスへの連絡先に関する情報。

Mitsubishi Electronics NGMU-Eについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMitsubishi Electronics NGMU-Eの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMitsubishi Electronics NGMU-Eで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)