  • Goodman Mfg GKS9 - page 1

    C US ® Copyright © 2006-2007, 2009 Goodman Manufacturing Company, L.P. This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. • Refer to Service Man ...

  • Goodman Mfg GKS9 - page 2

    PRODUCT IDENTIFICA TION 2 Furnace Type S : Single Stage/Multi-Speed The model and manufacturing number are used for positive identification of component parts used in manufacturing. When engineering and manufacturing changes take place where interchangeability of components are affected, the manufactur- ing number will change. It is very important ...

  • Goodman Mfg GKS9 - page 3

    PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. When engineering and manufacturing changes take place where interchangeability of components are affected, the manufactur- ing number will change. GKS90453BX* GKS90703BX* GKS90704CX* GKS90904CX* GKS90905DX* GKS ...

  • Goodman Mfg GKS9 - page 4

    4 PRODUCT DESIGN 2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace. 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chart for details. 4. Installer must supply the following gas line fitt ...

  • Goodman Mfg GKS9 - page 5

    5 COMPONENT IDENTIFICA TION 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Combustion Air Intake Connection / “Coupling” 4 Hot Surface Igniter 5 Burners 6 Rollout Limit 7 Flame Sensor 8 Flue Pipe Connection / “Coupling” 9 Flue Pipe (Internal) 1 0 Primary Limit 1 1 Pressure Switch 1 2 Gas Line Entrance 1 3 Rubber Elbow 1 4 Flue Pipe Connectio ...

  • Goodman Mfg GKS9 - page 6

    COMPONENT IDENTIFICA TION 6 GKS9 NOTE: Airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and noise issues. Cabinet Size A B C D E 13-5/8 17-1/2 20-7/8 All dimensions are in inches. GKS90453BX* GKS90703BX* GKS90704CX * GKS90904CX * GKS90905DX * GKS91155DX * 16 19-1/2 23 17-1/2 21 ...

  • Goodman Mfg GKS9 - page 7

    7 PRODUCT DESIGN * GKS9 furnaces are shipped without coil cover pressure switches. All GKS9 models are shipped from the factory as Dedicated Upflow but can be installed as a Horizontal Left or a Horizontal Right, ONLY after installing GKS9 Horizontal Installation Kit 0270K00012, which contains Pressure Switch 20197312. GKS90 453BX* -1.4 0 -1.20 -0. ...

  • Goodman Mfg GKS9 - page 8

    8 PRODUCT DESIGN Part Numbe r 20162903 20162904 20162906 Open Setti ng (°F) 160 150 170 GKS90453B X* 1 GKS90703B X* 1 GKS90704C X* 1 GKS90904C X* 1 GKS90905D X* 1 GKS91155D X* 1 T.O.D. PRIM ARY LIMIT Part Number 10123514 or 10123533 Open Se tting (°F) 200 GKS90453BX* 1 GKS90703BX* 2 GKS90704CX* 2 GKS90904CX* 2 GKS90905DX* 2 GKS91155DX* 2 ROLLOUT ...

  • Goodman Mfg GKS9 - page 9

    9 PRODUCT DESIGN Coil Matches: Coil Matches (for Goodman ® unit s using R22 and R-410A): • All CAPF coils in B, C, & D widths have insulated blank off plates for use with one size smaller furnaces. • All CAPF coils have a CAUF equivalent. • All CHPF coils in B, C & D heights have an insulated Z bracket for use with one size smaller f ...

  • Goodman Mfg GKS9 - page 10

    10 PRODUCT DESIGN Thermost ats: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This f ...

  • Goodman Mfg GKS9 - page 11

    FURNACE SPECIFICA TIONS 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altit ...

  • Goodman Mfg GKS9 - page 12

    BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed. 3. For ...

  • Goodman Mfg GKS9 - page 13

    BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 11 0 12 0 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTP UT BT U/HR x 1 000 BTU OUTPU T vs TEMPERAT URE RISE CHART T EM P ER AT U R E R I SE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT = CF M x 1 .08 x RISE RISE = BTU OUTP UT 1.08 ÷ CFM 800 ...

  • Goodman Mfg GKS9 - page 14

    14 WIRING DIAGRAMS HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL TIPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL I NJUR Y OR DE A TH . Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GKS9*****X** ...

メーカー Goodman Mfg カテゴリー Furnace

Goodman Mfg GKS9のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GKS9の取扱説明書
- Goodman Mfgの製品カード
- パンフレット
- またはGoodman Mfg GKS9の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Goodman Mfg GKS9の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Goodman Mfg GKS9の取り付け説明書、サービスマニュアル、簡易説明書、またはGoodman Mfg GKS9のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Goodman Mfg GKS9の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Goodman Mfg GKS9デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGoodman Mfg GKS9を使用するのを助ける技術的文書のことです。説明書は通常、全てのGoodman Mfg GKS9ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Goodman Mfgの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Goodman Mfg GKS9の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGoodman Mfg GKS9の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Goodman Mfg GKS9に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Goodman Mfg GKS9デバイスの基本機能を使うにあたってのヒント。 Goodman Mfg GKS9のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Goodman Mfg GKS9に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGoodman Mfg GKS9のメーカー/サービスへの連絡先に関する情報。

Goodman Mfg GKS9についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGoodman Mfg GKS9の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGoodman Mfg GKS9で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)