Mitsubishi FX-485ADPの取扱説明書

12ページ 0.18 mb
ダウンロード

ページに移動 of 12

Summary
  • Mitsubishi FX-485ADP - page 1

    USER'S GUIDE JY992D53201C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX and FX 0N , 485 communication adapters. It should be read and understood before attempt- ing to install or use these units. Further information can be found in the FX PROGRAMMING MANUAL, ...

  • Mitsubishi FX-485ADP - page 2

    1 INTRODUCTION ①⑥ LINK SG SDB SDA RDB RDA FG 24+ 24G 〈 FX-485ADP 〉 MITSUBISHI FX-485ADP ① Direct mounting hole ② Power LED · · · ③ R D L E D ······· ④ S D L E D ······· ⑤ Terminal screws (M3 (0.12)) ⑥ Extension cable ⑦ Terminal cover ⑧ Groove for mounting DIN rail (DIN rail width : 35 (1.38)) ⑨ Hook for mo ...

  • Mitsubishi FX-485ADP - page 3

    Station No.15 ↑ FX series PC Max. 16 stations including A series PCs (total extension distance 500m) (2) Computer and PC by 1 : n configuration In this case, the number of link stations is 16 PCs at maximum for one computer, including the FX series PCs and A series PCs. Such system of data exchange with plural PCs with one computer is called the ...

  • Mitsubishi FX-485ADP - page 4

    For setting up the system, the 485ADP can be connected to the following PCs. PC series FX 0N FX , FX 2C PC version Ver. 1.20 or later Ver. 3.30 or later Remarks Exclusive protocol format 1 and format 4 are supported. Exclusive protocol format 1 and format 4 are supported. FX 0N -485ADP FX-485ADP As for exclusive protocol formats (1, 4) , see the 48 ...

  • Mitsubishi FX-485ADP - page 5

    *1 R is the terminating resistance. Connect the terminating resistance (330 Ω ) between terminals SDA and SDB , and terminals RDA and RDB . For details see section 2.3. *2 Connect terminal FG to earth terminal of the PC main body grounded with resistance of 100 Ω or less. However, as for the computer link unit of the A series PC, see the manual ...

  • Mitsubishi FX-485ADP - page 6

    *1 R is the terminating resistance. Connect the terminating resistance (110 Ω ) between terminals RDA and RDB . For details see section 2.3. *2 Connect terminal FG to earth terminal of the PC main body grounded with resistance of 100 Ω or less. However, as for the computer link unit of the A series PC, see the manual of the computer link unit. ...

  • Mitsubishi FX-485ADP - page 7

    Classification of terminating resistances In this product, two sets of terminal end resistances (330 Ω ✕ 2, 110 Ω ✕ 1) are packaged, and the terminating resistances to be connected differ as shown below depending on the circuit being used. ● When communicating with the RS-422 circuit, connect the resistances of “330 Ω 1/4W ” as the ...

  • Mitsubishi FX-485ADP - page 8

    FX 0N FX, FX 2C The communication format of the PC is set using special D8120. Operating ambient temperature Humidity no condensation Shock resistance Noise immunity Dielectric withstand voltage Insulation resistance Ground Operating ambience 3 Environmental specifications Vibration resistance 0 to 55°C, storage temperature -20 to 70°C 35 to 85% ...

  • Mitsubishi FX-485ADP - page 9

    X0000 ~ X0177 Y0000 ~ Y0177 M0000 ~ M0511 S0000 ~ S0127 M0000 ~ M8254 TS000 ~ TS063 CS000 ~ CS031 CS235 ~ CS254 TN000 ~ TN063 CN000 ~ CN031 CN235 ~ CN254 D0000 ~ D0255 D1000 ~ D2499 D8000 ~ D8255 ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) X,Y,M,S T,C , D 4 Symbol ASCII code Command Function Objective device symbol Number of processing poin ...

  • Mitsubishi FX-485ADP - page 10

    In case of trouble, check the following points, and remedy according to the troubleshooting guide in the 485PC- IF manual. (1) Power LED Lit Otherwise (2) As for SD LED, RD LED, check and remedy according to the troubleshooting guide in the 485PC-IF manual. 5 DIAGNOSTICS : The extension cable is normally connected to the PC. : The extension cable i ...

  • Mitsubishi FX-485ADP - page 11

    Prior to start of operation, follow the procedure below. As for detail of procedure, see the 485PC-IF manual. 6 Determine system configuration Setting of transfer specification (D8120) Setting of station number (D8120) Setting of time-out check time (D8129) (1) (2) (3) Specification of data length Specification of parity Specification of stop bit S ...

  • Mitsubishi FX-485ADP - page 12

    Guidelines for the safety of the user and protection of the FX-485ADP, FX 0N -485ADP communication adapter JY992D53201C Effective AUG. 1997 Specifications are subject to change without notice. HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUCH TOKYO 100 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN ● This manual has b ...

メーカー Mitsubishi カテゴリー Computer Accessories

Mitsubishi FX-485ADPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FX-485ADPの取扱説明書
- Mitsubishiの製品カード
- パンフレット
- またはMitsubishi FX-485ADPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mitsubishi FX-485ADPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mitsubishi FX-485ADPの取り付け説明書、サービスマニュアル、簡易説明書、またはMitsubishi FX-485ADPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mitsubishi FX-485ADPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Mitsubishi FX-485ADPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMitsubishi FX-485ADPを使用するのを助ける技術的文書のことです。説明書は通常、全てのMitsubishi FX-485ADPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mitsubishiの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mitsubishi FX-485ADPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMitsubishi FX-485ADPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mitsubishi FX-485ADPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mitsubishi FX-485ADPデバイスの基本機能を使うにあたってのヒント。 Mitsubishi FX-485ADPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mitsubishi FX-485ADPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMitsubishi FX-485ADPのメーカー/サービスへの連絡先に関する情報。

Mitsubishi FX-485ADPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMitsubishi FX-485ADPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMitsubishi FX-485ADPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)