  • Aprilaire 8344 - page 1

    MODEL 8344 HEA T/COOL NON-PROGRAMMABLE MODEL 8346 HEA T PUMP NON-PROGRAMMABLE MODEL 8348 HEA T/COOL MUL TI-ST AGE NON-PROGRAMMABLE MODEL 8363 HEA T/COOL 5/2 DA Y PROGRAMMABLE MODEL 8365 HEA T PUMP 5/2 DA Y PROGRAMMABLE MODEL 8366 HEA T/COOL MUL TI-ST AGE 5/2 DA Y PROGRAMMABLE Installation Manual Electronic Thermostats ...

  • Aprilaire 8344 - page 2

    1 SPECIFICA TIONS Comfort Range 60°F – 80°F Comfort Control Accuracy ± 1 °F (applies to settings within Comfort Range) Operating Range 1 32°F – 99°F Maximum Control Accuracy ± 2°F T emperature Setting (Control) Range 50°F – 90°F heating; 60°F – 90°F cooling Switched Load V oltage 18 – 30 volts Maximum Operating Current 1.0 Amp ...

  • Aprilaire 8344 - page 3

    THERMOST A T INST ALLA TION INSTRUCTIONS Step 1. Choose a location to mount the thermostat • Approximately 5 feet off the floor (refer to local codes for compliance with the Americans with Disabilities Act). • On an interior wall where the temperature is most representative of the zone being controlled by the thermostat. • At least 18 inches ...

  • Aprilaire 8344 - page 4

    Step 3. Mount the thermostat on the wall There are two sets of mounting holes – one set for use when mounting to a junction box, another set for direct wall mounting. IMPORT ANT! TURN OFF POWER A T THE HVAC EQUIPMENT BEFORE PROCEEDING WITH THERMOST A T INST ALLA TION! Mounting the thermostat directly to the wall (without junction box) 1. Place th ...

  • Aprilaire 8344 - page 5

    Mounting the thermostat to a junction box 1. Install the top j-box screw (not included), until the head is approximately 1/8” from the surface of the wall. 2. Slide the thermostat on to the top screw . 3. Install the bottom screw (not included) to finish the installation. Step 4. Set the ELEC/GAS switch to the proper position (Models 8344, 8348, ...

  • Aprilaire 8344 - page 6

    Set the O/B reversing valve jumper in the proper position (Models 8346 and 8365 only) The thermostat comes with an O/B terminal which can be configured to be an ‘O’ terminal (for most heat pumps) or to be a ‘B’ terminal. Configure as an ‘O’ terminal if the heat pump reversing valve has heating as the default position, configure as a ‘ ...

  • Aprilaire 8344 - page 7

    APRILAIRE MODEL 8344 OR 8363 THERMOST A T FA N RELA Y 1ST ST AGE HEA T R FURNACE C G Y1 W1 1ST ST AGE COOL L1 L2 120 VA C 24 VA C 1ST STG COOL COOLING EQUIPMENT Y1 C LO HI W Y G RC RH HI opens at 100 ° F ± 9 ° F LO closes at 41 ° F ± 9 ° F AUT O ON GAS ELEC Step 5. Wire the thermostat IMPORT ANT! ENSURE THE POWER A T THE HVAC EQUIPMENT IS OFF ...

  • Aprilaire 8344 - page 8

    7 FA N RELA Y 2ND ST AGE HEA T 1ST ST AGE HEA T R HEA T/BLOWER EQUIPMENT C G Y1 W1 Y2 W2 1ST ST AGE COOL 2ND ST AGE COOL L1 L2 120 VA C 24 VA C 1ST STG COOL 2ND STG COOL COOLING EQUIPMENT Y1 C Y2 APRILAIRE MODEL 8348 OR 8366 THERMOST A T LO HI W RC RH W2 Y Y2 G HI opens at 100 ° F ± 9 ° F LO closes at 41 ° F ± 9 ° F GAS ELEC AUTO ON Diagram 2 ...

  • Aprilaire 8344 - page 9

    Step 6. Install supplied batteries Install two new AA alkaline batteries (included). Do not mix old and new batteries Step 7. Reassemble the thermostat No tools required – simply snap the thermostat face back on the thermostat. 8 Y1 O/B W2 L C R 1ST STG COMP . REV VA LVE DEFROST SERVICE OUTDOOR HEA T PUMP UNIT FA N RELA Y AUX. HEA T R HEA T/BLOWE ...

  • Aprilaire 8344 - page 10

    Step 8. Perform check-out 1. Slide the Fan switch to the On position. The blower should come on. Return the Fan switch to the Auto position. 2. Slide the Mode switch to the Heat position. 3. Use the ADJUST – Up button to raise the temperature 2° - 3° above the current room temperature. “HEA T” on the display will begin to flash and the heat ...

  • Aprilaire 8344 - page 11

    5. Return the Mode switch to the Off position to stop the heat call. 6. Slide the Mode switch to the Cool position. 7. Use the ADJUST – Down button to lower the temperature 2°- 3° below the current room temperature. “COOL” on the display will begin to flash and the cooling equipment should start. 8. MODELS 8348 & 8366 ONL Y – Lower th ...

  • Aprilaire 8344 - page 12

    Step 9. Set up temperature scale, differential, offset and Water Panel/filter change indicators 1. Slide the Mode switch to the Off position. 2. Press and hold both the ADJUST – Up and Down buttons until “ROOM” and “OFF” are no longer displayed. 3. °F/°C – Use the ADJUST – Up button to toggle between °F and °C. Press the LIGHT but ...

  • Aprilaire 8344 - page 13

    6. T emperature Offset (OF) – All thermostats are factory calibrated to be within 1° of true temperature. Offset is available to allow for agreement with field temperature measuring instruments. Use the ADJUST – Up or ADJUST – Down button to change the offset value between –4° and +4°. Press the LIGHT button when the desired offset value ...

  • Aprilaire 8344 - page 14

    9. Air Filter Change Indicator – Use this feature to remind the homeowner when an air filter change is needed. Use the ADJUST – Up and ADJUST – Down buttons to select the number of months between recommended filter changes. Use 1 or 3 for panel type filters and 6 or 12 for extended (pleated) media type filters. T ABLE 1 lists general recommen ...

  • Aprilaire 8344 - page 15

    14 10. Weekend Events – Use this feature to set the number of events for the weekend program. The default value is 4 events (The E NERGY S TA R ® setting), which will result in the “LEA VE” and “RETURN” events to be used during programmed operation. If the owners schedule is such that the home or building is generally occupied during the ...

  • Aprilaire 8344 - page 16

    Press the CURRENT TIME button to enter the minutes value and access the “day of the week” value. Use the ADJUST – Up and ADJUST – Down buttons to set the current day of the week. Press the CURRENT TIME button again to finish. The word “DONE” will appear on the display . As an E NERGY S TA R ® partner , the thermostat (Models 8363, 8365 ...

メーカー Aprilaire カテゴリー Thermostat

Aprilaire 8344のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 8344の取扱説明書
- Aprilaireの製品カード
- パンフレット
- またはAprilaire 8344の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Aprilaire 8344の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Aprilaire 8344の取り付け説明書、サービスマニュアル、簡易説明書、またはAprilaire 8344のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Aprilaire 8344の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Aprilaire 8344デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAprilaire 8344を使用するのを助ける技術的文書のことです。説明書は通常、全てのAprilaire 8344ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Aprilaireの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Aprilaire 8344の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAprilaire 8344の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Aprilaire 8344に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Aprilaire 8344デバイスの基本機能を使うにあたってのヒント。 Aprilaire 8344のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Aprilaire 8344に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAprilaire 8344のメーカー/サービスへの連絡先に関する情報。

Aprilaire 8344についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAprilaire 8344の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAprilaire 8344で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)