    MAR T pH TM INST ALLA TION GUIDE S Smart pH W a t er C h e m is try C o n trolle r I N T E L L I G E N C E I N S I D E A C U - T R O L I N S I D E w w w .a cu - tr o l.co m M ad e in U S A 1 1 0 VAC, 5A D is c onne c t p ow er s ource befo r e serv i cing uni t T u r n “ S e t P o in t ” k n o b t o t h e f a r left o r r ig h t to t r ig g e r ...

  • Pentair Smart pH - page 2

    ...

  • Pentair Smart pH - page 3

    Smart pH 3 PLEASE READ THIS USER MANUAL completely before installing or operating the equipment. The Smart pH TM is a Class 1 product for protection against electric shock and a T ype 1 product with regards to disconnection of the control circuits. Observe the following safety precautions:  Do not permit anyone untrained or under the age of 18 t ...

  • Pentair Smart pH - page 4

    Smart pH 4 1.4 SMART PH TM OVERVIEW SUMMARY : The Smart pH is a microprocessor based, modular automation system capable of continuous local monitoring and control of the pH water chemistry for pool and spa applications. The Smart pH will maintain the pH levels ( either increasing pH using base or decreasing pH using acid) of your water system autom ...

  • Pentair Smart pH - page 5

    Smart pH 5 INST ALLA TION SUMMAR Y 1. Identify new and existing equipment to be connected. 2. All controlled equipment must be 1 10 V AC (see Section 2.5.2) 3. Mount the Smart pH away from direct sunlight and on a flat vertical surface. 4. Connect the supply voltage with main breaker off (must be a separate dedicated circuit GFCI). MOUNTING THE SM ...

  • Pentair Smart pH - page 6

    Smart pH 6 ELECTRICAL SPECIFICA TIONS The following electrical specifications tabled below must not be exceeded. ITEM DESCRIPTION LIMIT Input V oltage Maximum Input AC V oltage 125 V AC Input Current Maximum Input Current 5 AMPS (AC) Input current Maximum Current for Single Relay 5 AMPS (AC) T emperature Minimum/Maximum Operating T emperature 30° ...

  • Pentair Smart pH - page 7

    Smart pH 7 PLUMBING INST ALLA TION Install the flow sensor and the pH sensor using the following steps: 1. T urn off all power to the system, close all isolation valves and then release any air from the system by turning the release valve on top of the system filter . 2. The flow sensor and pH sensor "T's" must be installed after ...

  • Pentair Smart pH - page 8

    Smart pH 8 SENSOR WIRING pH SENSOR Open front panel by removing the top two screws completely and unscrewing the lower two screws about half way . The front cover will now fold down like a shelf for easy access to the wiring connections and dipswitches. Route the sensor wires through the small strain relief into the Smart pH and to the appropriate ...

  • Pentair Smart pH - page 9

    Smart pH 9 2.9 SETTING THE DIP SWITCHES 1. Set the switches on the DIP Switch as to your requirements. (See fig 7.) S WI TC H Up Down 1 Acid Feed Base Feed 2 No Overfeed Limit 1 hr . Overfeed Limit 3 Do not change Do not change 4 Proportional Off Proportional On, 5% of Set Point 5 1 Min. Cycle T ime 3 Min. Cycle T ime 6 5% of the Cycle T ime. 20% ...

  • Pentair Smart pH - page 10

    Smart pH 10 Smart pH Water Chemistry Controller I N T E L L I G E N C E I N S I D E A C U - T R O L I N S I D E www.acu-trol.com Made in USA 110 V AC, 5A Disconnect power source before servicing unit T urn “Set Point” knob to the far left or right to trigger pH reading function (see manual for details) POWER HIGH BALANCED LOW CHEMICAL FEED pH p ...

  • Pentair Smart pH - page 11

    Smart pH 1 1 DIAGRAMS 120V AC SUPPL Y POWER WIRING TO 120V AC SUPPL Y POWER PIGT AIL T O CHEMICAL FEEDER PUMP (120V AC) ...

  • Pentair Smart pH - page 12

    Smart pH 12 EXPLODED VIEW 2 4 3 6 5 4A (4) Dia. # Description Part # 1 Knob with O-Ring ............................................................................................... 754000030 2 T op Half Replacement, Complete ....................................................................... 714000030 3 Relay Module ......................... ...

  • Pentair Smart pH - page 13

    Acu-T rol, Inc. 1 1830 Kemper Road Auburn, CA 95603 400000360 REV . A 6/1 1/2007 For T echnical Support Call 800-273- ...

メーカー Pentair カテゴリー Swimming Pool

Pentair Smart pHのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Smart pHの取扱説明書
- Pentairの製品カード
- パンフレット
- またはPentair Smart pHの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pentair Smart pHの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pentair Smart pHの取り付け説明書、サービスマニュアル、簡易説明書、またはPentair Smart pHのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pentair Smart pHの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pentair Smart pHデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPentair Smart pHを使用するのを助ける技術的文書のことです。説明書は通常、全てのPentair Smart pHユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pentairの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pentair Smart pHの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPentair Smart pHの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pentair Smart pHに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pentair Smart pHデバイスの基本機能を使うにあたってのヒント。 Pentair Smart pHのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pentair Smart pHに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPentair Smart pHのメーカー/サービスへの連絡先に関する情報。

Pentair Smart pHについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPentair Smart pHの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPentair Smart pHで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)