Mad Catz 5MPRA6C-146の取扱説明書

12ページ 0.21 mb
ダウンロード

ページに移動 of 12

Summary
  • Mad Catz 5MPRA6C-146 - page 1

    DYNA-GLAS TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS 5MPRA Series MODELS 5MPRA6C-146 5MPRA6C3-146 5MPRA6D-147 5MPRA6D3-147 5MPRA6E-148 5MPRA6E3-148 5MPRA6F-156 5MPRA6F3-156 STA-RITE FOREIGN SALES CORP. 175 WRIGHT STREET, DELAVAN, WISCONSIN 53115 USA Telephone: (414) 728-5551; Telefax: ...

  • Mad Catz 5MPRA6C-146 - page 2

    2 ‘5MPRA ’ SERIES PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘5MPRA’ Series Self-priming Centrifugal pump: • Is designed for use with swimming pools or as a centrifugal pump. • Is an excellent performer; durable, reliable. T able ...

  • Mad Catz 5MPRA6C-146 - page 3

    3 READ AND FOLLOW ALL INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal injury, or major property damage if ignored. warns about hazards tha ...

  • Mad Catz 5MPRA6C-146 - page 4

    4 INST ALL A TION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10'(3m). Allow use of short, di ...

  • Mad Catz 5MPRA6C-146 - page 5

    5 Piping: Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase size if a long run is needed. When using 1-1/2" pipe, connect to pump with 1-1/2" to 2" (38 to 51mm) reducing adapter. To avoid strains on the pump, support both suction and discharge pipes inde- pendently. Place these supports near the pump ...

  • Mad Catz 5MPRA6C-146 - page 6

    6 ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Ground Fault Circuit Interrupter (GFCI) tripping indica ...

  • Mad Catz 5MPRA6C-146 - page 7

    7 OPERA TION NOTICE: NEVER run pump dry. Running pump dry may damage seals, caus- ing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. If pump is being pressure tested ...

  • Mad Catz 5MPRA6C-146 - page 8

    8 Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do not cover pump with plastic. For outdoor/unprotected installations: 1. Enclose entire system in a weatherproof enclosure. 2 ...

  • Mad Catz 5MPRA6C-146 - page 9

    9 PUMP SER VICE Pump should only be serviced by qualified personnel. Be sure to prime pump (Pg. 7) before starting. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GA TE V ALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. To avoid dangerous or fatal electrical shock hazard, turn OFF powe ...

  • Mad Catz 5MPRA6C-146 - page 10

    10 Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge with small amount of liquid detergent; press ceramic seat into seal plate cavity firmly and squarely with finger pressure (Fig. 6). 2. If ceramic seat will not locate properly, remove it, place face up on bench and reclean cavity ...

  • Mad Catz 5MPRA6C-146 - page 11

    11 Clogged pipe/trap/impeller, worn impeller: 7. Make sure suction trap is not clogged; if it is, clean trap and strainer. 8. Make sure impeller is not clogged (follow steps 1 through 7 under “Removing Old Seal”, Page 9; check impeller for clogging; follow steps 7 through 11 under “Installing New Seal”, Page 10, for reassembly). 9. Impeller ...

  • Mad Catz 5MPRA6C-146 - page 12

    1 2 3 4 5 6 7 8 8A 8B Box A Box A 11 12 13 14 15B 15A 16 17 18 19 20 21 22 23 9 10 012 0394 BOX A For quick disconnect pipe connection parts: Adapter Union Pkg ..................... 11201-0153 O-Rings (2) .................... 35505- 1318 Key Part No. Description Qty. 1 Motor 115/230 Volt/1 Phase 1 Chart at right 2 Screw #10-32x1/2" 1 U30-692SS ...

メーカー Mad Catz カテゴリー Water Pump

Mad Catz 5MPRA6C-146のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 5MPRA6C-146の取扱説明書
- Mad Catzの製品カード
- パンフレット
- またはMad Catz 5MPRA6C-146の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mad Catz 5MPRA6C-146の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mad Catz 5MPRA6C-146の取り付け説明書、サービスマニュアル、簡易説明書、またはMad Catz 5MPRA6C-146のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mad Catz 5MPRA6C-146の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Mad Catz 5MPRA6C-146デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMad Catz 5MPRA6C-146を使用するのを助ける技術的文書のことです。説明書は通常、全てのMad Catz 5MPRA6C-146ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mad Catzの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mad Catz 5MPRA6C-146の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMad Catz 5MPRA6C-146の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mad Catz 5MPRA6C-146に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mad Catz 5MPRA6C-146デバイスの基本機能を使うにあたってのヒント。 Mad Catz 5MPRA6C-146のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mad Catz 5MPRA6C-146に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMad Catz 5MPRA6C-146のメーカー/サービスへの連絡先に関する情報。

Mad Catz 5MPRA6C-146についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMad Catz 5MPRA6C-146の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMad Catz 5MPRA6C-146で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)