National Instruments 3.xの取扱説明書

18ページ 0.42 mb
ダウンロード

ページに移動 of 18

Summary
  • National Instruments 3.x - page 1

    GETTING STARTED GUIDE NI-DAQ mx Base 3. x This guide describes how to install and conf igure the NI-D A Qmx Base 3. x software and a data acquisition (DA Q) device. This guide also describes how to verify that the device is operating properly . Note For information about NI-DA Qmx Base for Linux and Mac OS X, refer to ni.com/info and enter rddqld . ...

  • National Instruments 3.x - page 2

    NI-DAQmx Base Getting Started Guide 2 ni.com Devices Using the LabVIEW 8.5 PDA Module for Windows Mobile ............... ............... ................. .............. .......12 Create, Modify, and Configure a Task in NI-DAQmx Base.....13 Devices Using the LabVIEW 8.5 PDA Module for Windows Mobile ......................... ................. ..... ...

  • National Instruments 3.x - page 3

    © National Instruments Corporation 3 NI -DAQmx Base Getting Started Guide programs, subprograms, su broutines, d e vice names, functions, operation s, variables, f ilenames, and extensions. monospace italic Italic text in this font denotes text that is a placeholder for a word or value that you must supply . Related Documentation The following doc ...

  • National Instruments 3.x - page 4

    NI-DAQmx Base Getting Started Guide 4 ni.com NI-DAQmx Base NI-DAQmx Base is a driver that allows you to buil d applications that run using a PDA device and Windows. NI-DA Qmx Base includes the following features: • NI-D A Qmx Base is a subset of the NI-DA Qmx API and is similar in functionality to NI-DA Qmx. • NI-D A Qmx Base consists o f a Lab ...

  • National Instruments 3.x - page 5

    © National Instruments Corporation 5 NI -DAQmx Base Getting Started Guide Install Application Software Install the NI application softwa re, including LabVIEW, NI LabWindows/CVI, and NI Measurement Studio. PDA Mo dule users must use LabVIEW 8.5 PDA Module for Wi ndows Mobile with NI-DAQmx B ase 3.0. Refer to the Operating System , Application Soft ...

  • National Instruments 3.x - page 6

    NI-DAQmx Base Getting Started Guide 6 ni.com Install Support Files The NI-DAQmx Base installer detects the NI software inst alled on the operating system and automatical ly selects the latest versions of the driver, application software, and langua ge support files from the C D. The NI-D A Qmx Base installer disp lays which features will be install ...

  • National Instruments 3.x - page 7

    © National Instruments Corporation 7 NI -DAQmx Base Getting Started Guide Step 2. For Devices Using the LabVIEW 8.5 PDA Module for Windows Mobile Only—Run the PDA Setup Utility After running the NI-DAQmx Base in stallation, you must copy the driver files to the PDA device. C omplete the following steps to run the Pocket PC Driver Installatio n u ...

  • National Instruments 3.x - page 8

    NI-DAQmx Base Getting Started Guide 8 ni.com Step 4. Install the Devices, Accessories, and Cables NI PCMCIA Device Installation Caution Follo w proper ESD precaution s to ensure you are grou nded before installing the hardware. The NI PCMCIA device supports hot insertion on a PDA device, which means the NI PCMCIA device can be installed and removed ...

  • National Instruments 3.x - page 9

    © National Instruments Corporation 9 NI -DAQmx Base Getting Started Guide Caution Always grasp the cable by the connect or you are inserting or removing. Never pull directly on the I/O cable to unplug it from the PCMCIA de vice. 3. Attach the I/O cable. Be careful no t to put strain on the I/ O cable when inserting or removing the cable connector ...

  • National Instruments 3.x - page 10

    NI-DAQmx Base Getting Started Guide 10 ni.com NI CompactFlash Device Installation Caution Follo w proper ESD precaution s to ensure you are grou nded before installing the hardware. The NI CompactFlash device supports hot insertion on a PD A de vice, which means you can install and re move the NI CompactFlash device without rebooting the PDA de vic ...

  • National Instruments 3.x - page 11

    © National Instruments Corporation 11 N I-DAQmx Base Getting Started Guide 2. Attach the I/O cable. Be careful no t to put strain on t he I/O cable when inserting or removing the cable connector . Accessories and PCI/PXI Devices Install accessories and/or terminal bl ocks according to the instructions in their user guides. Install PCI and PXI devi ...

  • National Instruments 3.x - page 12

    NI-DAQmx Base Getting Started Guide 12 ni.com Devices Using the LabVIE W 8.5 PDA Module for Windows Mobile Using the NI-DAQmx Base Task Configur ation Utility is required when using devices with the LabVIEW 8.5 PDA Module for Win dows Mobile. In NI-DAQmx Base 3.0, task information is emb edded in the built application. Prior to building and downloa ...

  • National Instruments 3.x - page 13

    © National Instruments Corporation 13 N I-DAQmx Base Getting Started Guide Create, Modify , and Co nfigure a T ask in NI-DAQmx Base Create a new task or modi fy an existing task in the Task Configuration Utility task list. The pre-installed tasks are conf igured to work with the examples without modificatio ns. To modify an existing task, select i ...

  • National Instruments 3.x - page 14

    NI-DAQmx Base Getting Started Guide 14 ni.com Tip Y ou can view context help for the T ask C onfiguration Utility by pressing <Ctrl-H>. 6. Click Sav e & Exit when you are finished conf iguring your tasks. The task configuration is automatically sav ed into LabVIEW global variables. Y ou do not n eed to explicitly sav e the configuration. ...

  • National Instruments 3.x - page 15

    © National Instruments Corporation 15 N I-DAQmx Base Getting Started Guide Using T asks in an Application To use a preconfigured task in your application, complete the following steps: 1. Right-click the task/chann els in terminal on a NI-D A Qmx Base VI. 2. Select Create»Contr ol or Cr eate»Constant . 3. T ype the name of the task in the contro ...

  • National Instruments 3.x - page 16

    NI-DAQmx Base Getting Started Guide 16 ni.com The following f igure illustrates a ty pical NI-D A Qmx Base application in LabVIEW . The pictured task uses a preconfigured task to acquire and display a finite number of point s for multiple chan nels. Devices on LabVIEW 8.5 PD A Module for Windows Mobile Refer to Getting Started with the LabVIEW PDA ...

  • National Instruments 3.x - page 17

    © National Instruments Corporation 17 N I-DAQmx Base Getting Started Guide T raining Courses National Instruments offers trainin g courses for those interested in receiving more help developing an ap plication with NI products. To enroll in a course or obtain a detailed course outli ne, refer to ni.com/training . Where to Go for Support The Nation ...

  • National Instruments 3.x - page 18

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for m ore information a bout National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trad e names of their respective companie s. For patent s covering Nat ...

メーカー National Instruments カテゴリー Computer Accessories

National Instruments 3.xのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3.xの取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments 3.xの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments 3.xの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments 3.xの取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments 3.xのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments 3.xの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

National Instruments 3.xデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments 3.xを使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments 3.xユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments 3.xの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments 3.xの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments 3.xに関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments 3.xデバイスの基本機能を使うにあたってのヒント。 National Instruments 3.xのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments 3.xに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments 3.xのメーカー/サービスへの連絡先に関する情報。

National Instruments 3.xについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments 3.xの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments 3.xで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)