Kobe Range Hoods CH9642SQBの取扱説明書

35ページ 1.27 mb
ダウンロード

ページに移動 of 35

Summary
  • Kobe Range Hoods CH9642SQB - page 1

    K O B E B r a n d R a n g e H o o d Mod el No. CH96 30SQB (30”) CH9636SQB (3 6”) CH9642SQB (4 2”) CH9648SQB (4 8”) CH-196 SERIES – 10” HEIGHT INST ALLA TION INSTRUCTIONS AND OPERA T ION MANUAL ...

  • Kobe Range Hoods CH9642SQB - page 2

    - READ A N D SA VE T HESE I NST RUCT IONS - CONT ENTS IMPOR T ANT SAFETY INSTRUC TIONS .........................................................................1 COMPONEN TS OF P ACKAGE .......................................................................................3 INST ALL A TION ........................................................... ...

  • Kobe Range Hoods CH9642SQB - page 3

    1 IMPORT ANT SAFET Y INSTRUCT IONS - PLEASE READ T HIS SE CT ION CA REFUL L Y BE FO RE INST ALLA TION - W ARNIN G: TO REDU CE THE RISK OF FIRE, ELECTRIC SH O CK OR PERS ONA L INJUR Y , OBSERVE T HE FOLLOWI NG: 1) Installation a nd el ect rical wir ing mu st be done b y qualif ied professiona ls and in accordance with all applicable codes and sta nd ...

  • Kobe Range Hoods CH9642SQB - page 4

    2 W hat to D o In The Event O f a Range T op Grease Fir e • SMOTHER FL AMES wit h a close f itting lid, cooki e sheet, or metal tray , and then t urn off the bu rner . KEEP FLAMM ABL E O R COM BUSTIBLE MA TE R IAL A WA Y FROM FLAMES. If the f lam es do not go out immediately , E V ACUA TE TH E ARE A A ND C AL L TH E FIRE DEP A R TMENT or 91 1. ? ...

  • Kobe Range Hoods CH9642SQB - page 5

    3 COMPONENTS OF P ACKAGE (Must keep all material for r eturns or refunds) Range Hood Box Duct Co ver Box (Sold Se parately) {A} KOBE Range Ho od {B} W ar ranty Regis tratio n Card {C} In st ructio n Manual {D} Baffle F ilter -- 2 (30” , 36”, 42”) -- 3 (48”) {E} St ainless Steel S pacer -- 2 (30”) -- 2 (36”) -- 3 (42”) -- 2 (48”) {F} ...

  • Kobe Range Hoods CH9642SQB - page 6

    4 INST ALL A T ION PLEASE READ ENTIRE INSTRUCT IONS BEF ORE PROCEEDING Calculatio n before Inst alla tion T o calculate i nstallation, please refer to T ABLE 1 or T A BLE 2. (All calculation i n in ches.) - FO R UNDER T HE CABINET - T ABLE 1 A = Height of Floor to C eiling B = H eig ht of Floor to Counter T o p (S t anda r d: 36”) C = Preferred H ...

  • Kobe Range Hoods CH9642SQB - page 7

    5 SAFETY WA RNIN G H OOD MA Y HA V E VE R Y SHA RP EDGES; PLEA SE WEA R PROTECT IVE GLOVES I F IT IS N ECES S A R Y TO RE M OV E A NY P A RTS FOR I NST A LLING , CLE A NIN G O R SERVICI N G . N OT E: BE C A REFU L WH E N USING ELECT RICA L SCR EWDRIVER, DAMA GE TO THE H OOD MA Y OCCUR. Installation C onten ts UNDER THE CABINE T INST ALL A TION .... ...

  • Kobe Range Hoods CH9642SQB - page 8

    6 UNDER T HE CA B INET INST ALLA T ION P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: TO A VOID DAM AGE TO YOUR HO OD, PREVENT DEBRI S FROM ENT ERING THE VENT OPENI NG . • Decide the location of the v enting pipe f r om the hood to the outside. Refer to Figure 1. • A stra ight, short vent run will allow the hood to perform more ...

  • Kobe Range Hoods CH9642SQB - page 9

    7 4. Draw electrical wires through c abinet acces s o pening. 5. From inside of the hood, p l ace screw (not provided) into the exact center of each knockout hole and secure to cabinet bottom. Once all mounti ng screws are in pla ce, f i nish tig htening screws u nt il secure. CAUTI ON : MAKE SUR E T H E H OOD IS SECURE BEFORE RELEA SING . 6. For s ...

  • Kobe Range Hoods CH9642SQB - page 10

    8 A c c e s s o r i e s 9. Drop o il tunnel into recess support near re ar of hood. Refer to Figure 6. 10. Inst all b af fle f ilte rs and stainl ess sp acer(s). Refer t o Me as urem ents and Di agr ams on pa ge 22 fo r baffl e filt er and s tainl ess sp acer pla cem ent. Angle baffle f ilter toward ba ck o f hood  . Push baffle filter up until ...

  • Kobe Range Hoods CH9642SQB - page 11

    9 ST AND A LONE INST A LL A T ION *** This i nstallation only applies if installing wit h the CH1 1 20DC duct cover . P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: T O A VOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENI NG . • Decide the location of the venting pipe f r om t he hood to the ou tsid e. (Figure ...

  • Kobe Range Hoods CH9642SQB - page 12

    10 1. Using re fe rences in T A BLE 1 and M ea surements and Diagrams on p ages 19-21, mark th e le veling poin t of the hood. Positio n two mo unting screws (no t p rovided) o n the wall, leaving 1/8” sp ace a w ay f rom the wall. 2. Pu nctur e t he knockout wire access h ole at the back of the hood and draw the ele ctri cal wires through as sho ...

  • Kobe Range Hoods CH9642SQB - page 13

    11 D u c t C o v e r I n s t a l l a t i o n 6. Mark the p osition of t he in ner duct c over- mounting bracket {J} (provide d). Use reference E from T ABLE 2 a nd M ea surements and Diagrams on p age 20-2 1. Attach and sec ure inner duct cover- mounting bracket {J} with two scr ews (not provided) to the wall. Refer to Figure 15. NOTE: Inner duct c ...

  • Kobe Range Hoods CH9642SQB - page 14

    12 F i n a l A s s e m b l y 14. T u rn po wer ON in control pa ne l. Check a ll light and fan operation. 15. M ake su re to leave th is manual for the homeowner . Figure 19 1 2 3 4 5 ...

  • Kobe Range Hoods CH9642SQB - page 15

    13 OPERA T ION I NST RUCT IONS This KOBE hoo d is equi pped with six electronic contr ols, two powerful ce ntr i fugal squ ir rel cages with sta i nless steel oil tu nne l , sta i nless steel ba ff le filters and spacer(s), and bright 12- vol t 20-watt halogen lights (2 for 30” & 36” and 3 f or 42” & 48”). The six electronic button ...

  • Kobe Range Hoods CH9642SQB - page 16

    14 Figure 21 T urnin g Fan OFF: The 3-Minute Delay fun ction w il l only turn o ff f ans. The light se ttings w il l not be affected by the del ay function. 3-Min ute Delay - Press Pow er Co ntrol (On/Off) button once , th e LED li ght for th e ac tive sp eed will f lash and fa ns will shut off afte r 3 m in utes. - During this 3-m i nute delay , c ...

  • Kobe Range Hoods CH9642SQB - page 17

    15 MAINT ENA NCE SAFETY WAR NIN G NEVER PUT YOUR HA ND INTO AREA HOU SING THE F A N WH ILE T HE F AN IS OPERA T IN G . For optimal operation, clean ran ge hood and all ba ffle/spacer/ f ilter/oil tunnel/oil co ntainer regularly . T o Clean Hood Surface CAUTI ON : N EV ER USE A BRAS IVE CLEAN ERS, P A DS, OR CLOTHS. *** Regular care will help preser ...

  • Kobe Range Hoods CH9642SQB - page 18

    16 T o Replace Light Bul b CAUTI ON : HA LOGE N L IGH T UNIT MA Y BE HOT! W AI T UNTIL UN IT IS COO L.                 1. Make sure all controls are of f, and range hood is unplugged. 2. Place a flat- head screwdriver between li gh t cover and hou si ng  to remove cover  . 3. Gently pu ll d efec ...

  • Kobe Range Hoods CH9642SQB - page 19

    17 SPECIFICA T IONS MODEL / SIZE CH96 30SQB / 30” CH96 36SQB / 36" CH96 42SQB / 42” CH96 48SQB / 48” COLOR #304 Comm erc i a l Grade S ta i n less S teel CONSUMP TION / A M PERE CH96 30SQB – 300 W / 3A CH96 36SQB – 300 W / 3A CH96 42SQB – 300 W / 3A CH96 48SQB – 300 W / 3A VOL TA GE 120V 60 Hz NUMBER O F MO TORS 2 DESIGN Seamles ...

  • Kobe Range Hoods CH9642SQB - page 20

    18 MEASUREMENT S & DIAGRAMS  A ll ( ) a re in mi llimeter .  A ll inch measurements are converted from millim eters. Inch measurement s are esti mated. - FO R UNDER T HE CABINET - MODEL NO: CH9630 SQB CH963 6 SQB CH964 2 SQB CH964 8 SQB ...

  • Kobe Range Hoods CH9642SQB - page 21

    19  A ll ( ) a re in mi llimeter .  A ll inch measurements are converted from millim eters. Inch measurement s are esti mated. - FO R S T AND A L ONE (WIT H OPTIONAL DU CT COVER) - MODEL NO: CH9630 SQB CH963 6 SQB CH964 2 SQB CH964 8 SQB ...

  • Kobe Range Hoods CH9642SQB - page 22

    20 Rear Knocko ut Holes 2 4 " ( 6 0 8 ) f o r 4 2 " 3 0 " ( 7 6 0 ) f o r 4 8 " 1 8 " ( 4 5 6 ) f o r 3 6 " 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( 7 5 ) 1 2 " ( 3 0 4 ) f o r 3 0 " ...

  • Kobe Range Hoods CH9642SQB - page 23

    21 Hood-Mounting Bracke t DUCT COVER-MOUN T ING BR ACKE T I nn er Duct Cove r-Mounting Br acket Outer Duct Cover- Mounting Br acket 8 - 5 / 8 " ( 2 2 0 ) 1 1 - 3 / 4 " ( 2 9 8 ) 7/8" (22) 1/8" (4.5) 3 - 1 / 8 " ( 8 0 ) 2 - 1 / 4 " ( 5 7 ) 1/8" ( 3.4) 9" (2 28) 10-1/4" (260) 9" (228) 4-3/4" (120 ...

  • Kobe Range Hoods CH9642SQB - page 24

    22 BA FF LE F IL T ER & S T AINLESS ST EEL SP ACERS 48 ″ H00D 42 ″ H00D 30 ″ H00D 36 ″ H00D ...

  • Kobe Range Hoods CH9642SQB - page 25

    23 P ART S LIST M ODEL N O.: CH 96 30SQB CH 96 36 SQB CH 96 42 SQB CH 96 48 SQB Body Compo nents NO. DESCRIPTION MODEL/SIZE P AR T NO. 1 Screws (3/16” x 3/8”) CH196- 1 2 Hood Ca sing CH196- 2 3 Hood- Mounting Bracket CH196- 3 4 Screws (3/16” x 3/8”) CH196- 1 5 S tai nless S teel Oil T unnel CH196- 4 6 Blower Asse mbly CH196- 5 7 Hal ogen Li ...

  • Kobe Range Hoods CH9642SQB - page 26

    24 3 2 1 4 5 6 7 1 0 8 9 1 5 1 6 1 8 1 9 1 7 1 4 1 3 1 1 1 2 B 1 2 C 1 2 1 2 A 2 0 2 1 2 2 1 2 D ...

  • Kobe Range Hoods CH9642SQB - page 27

    25 Blower Assembly NO. DESCRIPTION MODEL/SIZE P ART NO. 1 Air Chamber CH196- 6.1 2 Screw Cap CH196- 6.2 3 Left Squirrel Cage CH196- 6.3 4 Left Locknut CH196- 6.4 5 Air Flow Grill CH196- 6.5 6 Screws (3/16” x 3/8”) CH196- 6.6 7 Rig ht Locknut CH196- 6.7 8 Rig ht Squirrel Cage CH196- 6.8 9 Gasket CH196- 6.9 10 Screw s (3 /16” x 3/8”) CH196-6 ...

  • Kobe Range Hoods CH9642SQB - page 28

    26 Electrical A ssemb ly NO. DESCRIPTION MODEL/SIZE P ART NO. 1 Elect rical Box CH196- 15.1 2 Screws (3/16” x 3/8”) CH196- 15.2 3 Processor Board CH196- 15.3 4 Elect rical Box Cover CH196- 15.4 5 Setup Boar d CH196- 15.5 6 Gasket CH196- 15.6 7 Screws (3/16” x 3/8”) CH196- 15.2 8 T ransf orm er CH196- 15.7 9 Screws (3/16” x 3/8”) CH196- ...

  • Kobe Range Hoods CH9642SQB - page 29

    27 CIRCUIT DIAGRAM M ODEL N O.: CH 96 30SQB CH 96 36 SQB MOTOR MOTOR CAPACITOR 10uF/450V CAPACITOR 10uF /450V TRANSFORMER PROCESSO R BOARD CONTROL BOARD HALOGEN LIGH T RED BLACK WHITE YELLOW GREEN BROWN BROWN RED RED GREEN GREEN WHITE WHITE RED BLACK BLACK BLACK WHITE RED 120V 60Hz ...

  • Kobe Range Hoods CH9642SQB - page 30

    28 M ODEL N O.: CH 96 42SQB CH 96 48 SQB 120V 60Hz RED WHITE BLACK BLACK BLACK RED WHITE WHITE GREEN GREEN RED RED BROWN BROWN GREEN YELLOW WHITE BLACK RED HALOGEN LIGHT CONTROL BOARD PROCESSOR BOARD TRANSFORMER CAPACITOR 10uF/450V CAPACITOR 10uF/450V MOTOR MOTOR ...

  • Kobe Range Hoods CH9642SQB - page 31

    29 DISCLAIMER 1. C A RE FULL Y INSPECT A L L ITE MS FO R D AMAGES BEF ORE A CCEP TING DE LIVER Y . N OT E A NY DAMAGES ON T H E FREIGH T BILL OR E XPRESS RECEI PT . REQUEST NAM E AND SIGNA T URE OF T HE CA RR IER’S A GE NT A ND KEEP C OPY T O SUPPORT YOU R CL A IM. Upon accepta nce of items, owner assumes responsibility f or its safe a rrival. Re ...

  • Kobe Range Hoods CH9642SQB - page 32

    30 W ARR AN T Y W ARRAN T Y CERT IFI C A T E KOBE Range Hoods, Inc. warra nts all products m anufa ctured or supp li ed by it to b e f ree from de fects in workmanship and materials. Its obligations p ursuant t o this w arranty a re lim ited to a period of two years f rom the d ate of purchase and to the rep air or replacement at its o ption and su ...

  • Kobe Range Hoods CH9642SQB - page 33

    31 3) The purchaser shall b e responsible fo r any e xp en ses involved in m aking the range hood re adil y acces si ble for servicing and where the r ange h ood is installed outsi de the main sales te rrit ory of the retailer or service territory of th e nearest approv ed KO BE Ran ge Hoods Agen t a s applic ab le, fo r an y traveling expenses and ...

  • Kobe Range Hoods CH9642SQB - page 34

    32 PRODUCT REGISTRA T ION Regist er Y our P roduct! Any covere d failure occu rrin g within two year s of original purchase arising f rom d efe ctive workmanship o r ma terial in manu fac ture will be repaired o r at our opt ion the unit will be replaced f r ee o f charge by an authorized KOBE Range Hoods Agent or KOBE Ran ge Hoods as applic ab le. ...

  • Kobe Range Hoods CH9642SQB - page 35

    KOBE Range Hoo ds 10505 V alley Bl vd Suite # 302 El Monte , CA 9173 1 USA http:// www .K OB ERan geH oods.c om This KOBE ho od is m anu factur ed f or use i n the USA and C ANADA only . W e do not recommend usi ng this hood overseas as the po wer su pply m ay not be compatible and m ay vio l ate t he electrical code of that country . Using a KOBE ...

メーカー Kobe Range Hoods カテゴリー Ventilation Hood

Kobe Range Hoods CH9642SQBのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CH9642SQBの取扱説明書
- Kobe Range Hoodsの製品カード
- パンフレット
- またはKobe Range Hoods CH9642SQBの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Kobe Range Hoods CH9642SQBの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Kobe Range Hoods CH9642SQBの取り付け説明書、サービスマニュアル、簡易説明書、またはKobe Range Hoods CH9642SQBのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Kobe Range Hoods CH9642SQBの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Kobe Range Hoods CH9642SQBデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがKobe Range Hoods CH9642SQBを使用するのを助ける技術的文書のことです。説明書は通常、全てのKobe Range Hoods CH9642SQBユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Kobe Range Hoodsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Kobe Range Hoods CH9642SQBの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははKobe Range Hoods CH9642SQBの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Kobe Range Hoods CH9642SQBに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Kobe Range Hoods CH9642SQBデバイスの基本機能を使うにあたってのヒント。 Kobe Range Hoods CH9642SQBのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Kobe Range Hoods CH9642SQBに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるKobe Range Hoods CH9642SQBのメーカー/サービスへの連絡先に関する情報。

Kobe Range Hoods CH9642SQBについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもKobe Range Hoods CH9642SQBの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがKobe Range Hoods CH9642SQBで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)