Lincoln Electric R3R 375-Iの取扱説明書

28ページ 0.67 mb
ダウンロード

ページに移動 of 28

Summary
  • Lincoln Electric R3R 375-I - page 1

    IDEALARC ® R3R 375-I, 500-I AND 600-I OPERA T OR’S MANUAL IM410-D June, 2009 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation ... and thoughtful operation on you r part . DO NO T INST ALL, OPERA TE OR REP AIR THIS EQUI ...

  • Lincoln Electric R3R 375-I - page 2

    i SAFETY i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ____________________________________ ...

  • Lincoln Electric R3R 375-I - page 3

    ii SAFETY ii ARC R A Y S can bur n. 4.a. Use a shield with the proper f ilter and co ver plates t o prot ect your e yes fr om sparks and the ra ys of the ar c when welding or observing open arc welding . Headshield and filter lens should conform to ANSI Z87 . I standar ds. 4.b . Use suitab le clothing made from dur able flame-r esistant material to ...

  • Lincoln Electric R3R 375-I - page 4

    iii SAFETY iii IDEALARC® R3R 375-I, 500-I AND 600-I FOR ELECTRIC ALL Y pow ered equipment. 8.a. T urn off input po wer using the disconnect switch at the fuse bo x before w orking on the equipment. 8.b . Install equipment in accordance with the U .S. National Electrical Code, all local codes and the manuf acturer’s recommendations . 8.c. Ground ...

  • Lincoln Electric R3R 375-I - page 5

    iv SAFETY iv Mar . ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ’Arc 1. Protegez-vous contre la secousse électrique: a. L ...

  • Lincoln Electric R3R 375-I - page 6

    v v Thank Y ou f or selecting a QU ALITY product b y Lincoln Electric. We want y ou to t ake pride in operating this Lincoln Electric Compan y product ••• as much pride as we hav e in br inging this product t o you! Read this Oper ators Manual complet ely bef ore at tempting to use this equipment. Sa v e this manual and k eep it handy f or qu ...

  • Lincoln Electric R3R 375-I - page 7

    vi T ABLE OF CONTENTS IDEALARC® R3R 375-I, 500-I AND 600-I vi Page I n s t a l l a t i o n .........................................................S e c t i o nA I n p u t P o w e r C o n n e c t i o n .................................................A - 1 D u t y C y c l e ............................................................ A - 1 O u t ...

  • Lincoln Electric R3R 375-I - page 8

    A-1 INST ALLA TION IDEALARC® R3R 375-I, 500-I AND 600-I A-1 INST ALLA TION F ALLING EQUIPMENT can cause injury . • Do not lift this machine using lift bail if it is equipped with a heavy • accessory such as trailer or gas cylinder . • Lift only with equipment of adequate lifting capacity . • Be sure machine is stable when lifting. The mach ...

  • Lincoln Electric R3R 375-I - page 9

    B-1 OPERA TION B-1 OPERA TION ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet cloth- ing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. FUMES AND GASES can be danger- ous. • Keep your head out of fumes. • Use ventilation or exhaust to • remove fumes from brea ...

  • Lincoln Electric R3R 375-I - page 10

    B-2 OPERA TION B-2 B. ARC FORCE CONTROL DIAL Arc Force Increase/Decrease of Arc Force C. OUTPUT CURRENT CONTROL DIAL Output Current D. OUTPUT CURRENT CONTROL RANGE SWITCH (R3R 500-I and R3R 600-I only) Output Current Control Dial Range A Output Current Control Dial Range B E. OUTPUT CURRENT CONTROL “MACHINE- REMOTE” SWITCH Remote Output Current ...

  • Lincoln Electric R3R 375-I - page 11

    C-1 ACCESSORIES C-1 OPTIONAL EQUIPMENT K857 – REMOTE CURRENT CONTROL The K857 consists of a control box with 8.5 m (28 ft) of four conductor cable and a 6 pin Amphenol for easy connection to the front of the power source. The K857 will give the same control as the current con- trol on the machine depending on the position of the current dial sele ...

  • Lincoln Electric R3R 375-I - page 12

    D-1 MAINTENANCE D-1 ELECTRIC SHOCK can kill. • Have an electrician install and ser- vice this equipment. • T urn the input power off at the fuse box before working on equipment. • Do not touch electrically hot parts. ROUTINE MAINTENANCE 1. The fan motor has sealed bearings which require no service. 2. In extremely dusty locations, dirt may cl ...

  • Lincoln Electric R3R 375-I - page 13

    E-1 TROUBLESHOOTING E-1 IDEALARC® R3R 375-I, 500-I AND 600-I If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This T roubleshooting Guide is provided to hel ...

  • Lincoln Electric R3R 375-I - page 14

    E-2 TROUBLESHOOTING E-2 IDEALARC® R3R 375-I, 500-I AND 600-I Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you pr ...

  • Lincoln Electric R3R 375-I - page 15

    E-3 TROUBLESHOOTING E-3 IDEALARC® R3R 375-I, 500-I AND 600-I Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you pr ...

  • Lincoln Electric R3R 375-I - page 16

    E-4 TROUBLESHOOTING E-4 IDEALARC® R3R 375-I, 500-I AND 600-I Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you pr ...

  • Lincoln Electric R3R 375-I - page 17

    E-5 TROUBLESHOOTING E-5 IDEALARC® R3R 375-I, 500-I AND 600-I Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you pr ...

  • Lincoln Electric R3R 375-I - page 18

    E-6 TROUBLESHOOTING E-6 IDEALARC® R3R 375-I, 500-I AND 600-I Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you pr ...

  • Lincoln Electric R3R 375-I - page 19

    E-7 TROUBLESHOOTING E-7 IDEALARC® R3R 375-I, 500-I AND 600-I Low output, low OCV , or erratic welding T urn control dial to minimum Check OCV OCV is 35-55V OCV is 40-45V OCV is 0 Rated OCV but OCV less than rated erratic welding but more than 55V OCV 45-55V OCV 35-45V Possible machine Check leads 76, 77, Possible Loose lead Possible intermittent P ...

  • Lincoln Electric R3R 375-I - page 20

    E-8 TROUBLESHOOTING E-8 TROUBLESHOOTING PROCEDURES A. PROCEDURE FOR REPLACING PC BOARDS When a PC board is to be replaced, the following procedure must be followed: 1. Visually inspect PC board in question. Are any of the components damaged? Is a conductor on the back side of the board damaged? a. If there is no damage to the PC board, insert a new ...

  • Lincoln Electric R3R 375-I - page 21

    E-9 TROUBLESHOOTING E-9 (high resistance value). This indicates that the capacitor in the snubber circuit is taking a charge. 3. If the needle stays to the right, the capacitor is shorted and the assembly is defective. 4. If the needle does not move, the capacitor is open and the assembly is defective. G. CHECKING CURRENT CONTROL RHEOST A T ON MACH ...

  • Lincoln Electric R3R 375-I - page 22

    E-10 TROUBLESHOOTING E-10 2. POWER DIODE TEST a. Establish the polarity of the ohmmeter leads and set to X10 scale. b. Connect the ohmmeter positive lead to anode and negative lead to the cathode. c. Reverse the leads of the ohmmeter from Step b. d. A shorted diode will indicate zero or an equal- ly low resistance in both directions. An open diode ...

  • Lincoln Electric R3R 375-I - page 23

    F-1 WIRING DIAGRAMS F-1 IDEALARC® R3R 375-I, 500-I AND 600-I NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. ELECTRICAL SY MBOLS PER E1537 LEGEND D5 D 6 D 7 POCKET AMPT ROL SE NSING BRID ...

  • Lincoln Electric R3R 375-I - page 24

    F-2 WIRING DIAGRAMS IDEALARC® R3R 375-I, 500-I AND 600-I F-2 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. ...

  • Lincoln Electric R3R 375-I - page 25

    F-3 WIRING DIAGRAMS IDEALARC® R3R 375-I, 500-I AND 600-I F-3 R3R 375-I, 500-I and 600-I K817 or K817R (K841 not shown) Part No. T ype AB C D F G H M12244-7 R3R 32.00 15.39 3092 1.44 30.02±.1 1 33.07±.06 .94 M12244-7 7-7-78 ...

  • Lincoln Electric R3R 375-I - page 26

    IDEALARC® R3R 375-I, 500-I AND 600-I W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS I ...

  • Lincoln Electric R3R 375-I - page 27

    IDEALARC® R3R 375-I, 500-I AND 600-I W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep y our he ad out o f fume s. ● Use ...

  • Lincoln Electric R3R 375-I - page 28

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .lincolnelectric.com • World's Leader in W elding and Cutting Products • ...

メーカー Lincoln Electric カテゴリー Welder

Lincoln Electric R3R 375-Iのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- R3R 375-Iの取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric R3R 375-Iの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric R3R 375-Iの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric R3R 375-Iの取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric R3R 375-Iのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric R3R 375-Iの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Lincoln Electric R3R 375-Iデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric R3R 375-Iを使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric R3R 375-Iユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric R3R 375-Iの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric R3R 375-Iの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric R3R 375-Iに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric R3R 375-Iデバイスの基本機能を使うにあたってのヒント。 Lincoln Electric R3R 375-Iのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric R3R 375-Iに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric R3R 375-Iのメーカー/サービスへの連絡先に関する情報。

Lincoln Electric R3R 375-Iについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric R3R 375-Iの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric R3R 375-Iで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)