    INST ALLA TION OVER VIEW 2 The following should be always observed for safety .................... 3 Installation of indoor, outdoor unit ................................................ 4 Flaring work and connection of piping ........................................... 6 Connection of piping(Indoor) ...... 7 For left rear piping For right rear pip ...

  • Heat Controller HMC30AS-1 - page 3

    THE FOLLOWING SHOULD BE AL W A YS OBSER VED FOR SAFETY 3 ■ Be sure to read "THE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETY" before installing the air conditioner. ■ Be sure to observe the cautions specified here as they include important items related to safety. ■ The indications and meanings are as follows. ■ After reading th ...

  • Heat Controller HMC30AS-1 - page 4

    4 INST ALLA TION OF INDOOR, OUTDOOR UNIT Read completely, then follow step by step. Select the best location Indoor unit ■ Do not have any heat or steam near the unit. ■ Select a place where there are no obstacles in front of the unit. ■ Make sure that condensation drainage can be conveniently routed away. ■ Do not install near a doorway. ? ...

  • Heat Controller HMC30AS-1 - page 5

    5 How to mount installation plate The wall you select should be strong and solid enough to prevent vibration Mount the installation plate on the wall with four type A screws. If mounting the unit on a concrete wall, use anchor bolts. ■ Mount the installation plate horizontally by aligning the centerline using a level. Measure the wall and mark th ...

  • Heat Controller HMC30AS-1 - page 6

    6 Connection of piping -Indoor FLARING WORK AND CONNECTION OF PIPING Flaring wor k Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure. Cut the pipes and the cable. ■ Use the piping kit accessory or the pipes purchased locally. ■ Measure the distance between the indoor and the o ...

  • Heat Controller HMC30AS-1 - page 7

    7 Main PCB Low panel Lower panel CAUTION When install, make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose, especially power cord and connecting cable. Route the indoor tubing and the drain hose in the direction of rear left. Insert the connecting cable into the indoor unit from the outdoor unit ...

  • Heat Controller HMC30AS-1 - page 8

    Wrap the insulation material around the connecting portion. ■ Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap. F Route the indoor tubing and the drain hose to the required piping hole position. A Insert the piping, drain hose and the connectin ...

  • Heat Controller HMC30AS-1 - page 9

    9 Insert the connecting cable into the indoor unit. ■ Don't connect the cable to the indoor unit. ■ Make a small loop with the cable for easy connection later. Tape the drain hose and the connecting cable. • Connecting cable C D Installation plate Three upper hooks Installation plate Indoor unit Three lower hooks Setting line Connecting ...

  • Heat Controller HMC30AS-1 - page 10

    10 Reroute the pipings and the drain hose across the back of the chassis. Reinstall the parts to the original position. ■ Refix the lower panel to the original position. ■ The chassis bottom(A) should be connected to the steel chassis(B) with green/yellow wiring using two screws. ■ Connect display conductor. ■ Refix the front right side pan ...

  • Heat Controller HMC30AS-1 - page 11

    11 ■ Unfold the tubing to downward slowly. ( ) ■ Bend the tubing to the left side of chassis. Installation Information (For left piping) • Good case For left piping. Follow the instruction below. ■ Press on the upper side of clamp. ( ) • Bad case ■ Following bending type from right to left could cause problem of pipe damage. CAUTION CAU ...

  • Heat Controller HMC30AS-1 - page 12

    12 Connection of piping -Outdoor Put a couple drops of refrigerant oil on the face of the flare before assembling taking care not to add any contaminants. Align the center of the pipings and sufficiently tighten the flare nut by hand. Connection of the drain hose ■ The drain hose can be connected at two different positions. Use the most convenien ...

  • Heat Controller HMC30AS-1 - page 13

    13 CAUTION Ø 8.5mm (0.33in) 20m m (0.79in) G N/YL AWG #12 20m m (0.79in) G N/YL AWG #20 The power supply cord connected to the outdoor unit should be complied with the following specifications (UL and CSA recognized one). The connecting cable connected to the indoor and outdoor unit should be complied with the following specifications (UL and CSA ...

  • Heat Controller HMC30AS-1 - page 14

    14 Connect the cab le to the outdoor unit Remove the control cover from the unit by loosening the screw. Connect the wires to the terminals on the control board individually. Secure the cable onto the control board with the cord clamp. Refix the control cover to the original position with the screw. Use a recognized circuit breaker 30A (30k) betwee ...

  • Heat Controller HMC30AS-1 - page 15

    15 CHECKING THE DRAINAGE AND FORMING THE PIPINGS Chec king the drainage Right side panel Lower panel To check the drainage. ■ Pour a glass of water on the drain pan. ■ Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. D Drain piping ■ The drain hose should point downward for easy ...

  • Heat Controller HMC30AS-1 - page 16

    16 F orm the piping Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vinyl tapes. ■ If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. In cases where the outdoor unit is in ...

  • Heat Controller HMC30AS-1 - page 17

    17 AIR PURGING Air purging Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. ■ Pressure in the system rises. ■ Operating current rises. ■ Cooling(or heating) efficiency drops. ■ Moisture in the refrigerant circuit may freeze and block capillary tubing. ■ Water may lead to corrosion of parts ...

  • Heat Controller HMC30AS-1 - page 18

    18 Evacuation ■ Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold valve is open. Then, run the vacuum pump. The operation time for evacuation varies with tubing length and capacity of the pump. The following table shows the time r ...

  • Heat Controller HMC30AS-1 - page 19

    19 ■ Each outdoor unit is factory charged (nameplate charge) for the evaporator as well as a 7.5m(25ft) line set. Any time a line set is used either shorter or longer then the nominal 7.5m(25ft) line set length the refrigerant charge has to adjusted. ■ Whether the line set is made shorter or longer you must adjust the charge based on how many f ...

  • Heat Controller HMC30AS-1 - page 20

    20 Outside ambient TEMP. The pressure of the gas side service valve 35 ° C(95 ° F) 4~5kg/cm 2 G(56.8~71.0 P.S.I.G.) TEST RUNNING Settlement of outdoor unit ■ Anchor the outdoor unit with a bolt and nut( ø 10mm(0.39in) tightly and horizontally on a concrete or rigid mount. ■ When installing on the wall, roof or rooftop, anchor the mounting ba ...

  • Heat Controller HMC30AS-1 - page 21

    MEMO 21 ...

  • Heat Controller HMC30AS-1 - page 22

    MEMO 22 ...

  • Heat Controller HMC30AS-1 - page 23

    P/No. : 3829A20001V Specifications and performance data subject to change without notice. ...

メーカー Heat Controller カテゴリー Heat Pump

Heat Controller HMC30AS-1のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HMC30AS-1の取扱説明書
- Heat Controllerの製品カード
- パンフレット
- またはHeat Controller HMC30AS-1の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heat Controller HMC30AS-1の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heat Controller HMC30AS-1の取り付け説明書、サービスマニュアル、簡易説明書、またはHeat Controller HMC30AS-1のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heat Controller HMC30AS-1の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Heat Controller HMC30AS-1デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeat Controller HMC30AS-1を使用するのを助ける技術的文書のことです。説明書は通常、全てのHeat Controller HMC30AS-1ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heat Controllerの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heat Controller HMC30AS-1の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeat Controller HMC30AS-1の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heat Controller HMC30AS-1に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heat Controller HMC30AS-1デバイスの基本機能を使うにあたってのヒント。 Heat Controller HMC30AS-1のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heat Controller HMC30AS-1に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeat Controller HMC30AS-1のメーカー/サービスへの連絡先に関する情報。

Heat Controller HMC30AS-1についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeat Controller HMC30AS-1の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeat Controller HMC30AS-1で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)