  • Heatcraft Refrigeration Products H-IM-77D - page 1

    Installation and Operation Manual Reach-In Unit C oolers H-IM-77D June, 2006 Part No . 25005601 T able of C ontents Inspection ................................................................................. 2 Installation ................................................................................ 2 Expansion Valv e .......................... ...

  • Heatcraft Refrigeration Products H-IM-77D - page 2

    2 Inspection When the equipment is receiv ed, all items should be carefully checked against the bill of lading to make sure all crates and cartons have been r eceived. All units should be carefully inspected for hidden damage when rec eived. If any damage is found, it should be r eported to the carrier immediately and a claim should be led. The ...

  • Heatcraft Refrigeration Products H-IM-77D - page 3

     Description All Sizes Part Number 115V Motor 2500701 208/20V Motor 2500801 Fan Blade 5101B Fan Guard 5054D Motor Mount 91179001 Thin Profile Air Defrost Unit Cooler Mounting The thin profile air defrost unit cooler is designed for mounting from the top of the cooler . Drill holes f or screws in accor dance with moun ting dimensions A a ...

  • Heatcraft Refrigeration Products H-IM-77D - page 4

    4 Expansion Valve Recommendations -10°F . Suction 10° TD -15°F . Suction 15° TD M o d e l B T U H R - 4 0 4 B T U H R - 4 0 4 A Size 10° TD Alco Sporlan 15° TD Alco Sporlan 09 900 150 12 1200 HFS 1 / 8 SZ EFS 1 / 8 Z 1800 HFS 1 / 8 SZ EFS 1 / 8 Z 16 1600 2400 21 2100 150 HFS 1 / 4 SZ EFS 1 / 6 Z 28 2800 HFS 1 / 4 SZ EFS 1 / 6 Z 4200 HFS ...

  • Heatcraft Refrigeration Products H-IM-77D - page 5

    5 Motor Heater Model No. of Amps. Amps. Size Motors A* B* A* B* 09 1 0.8 0.4 4.1 2.07 12 2 1.6 0.8 5.22 2.61 16 2 1.6 0.8 6.09 .04 21 1 1.0 0.5 9.57 4.78 28  - 1.2 - 5.7 5 2 - 1.0 - 7.0 5  - 1.5 - 8.5 P a r t 115 Volt 208-230 V olt Description 09 12 16 21 09 12 16 21 28 35 53 Motor 2500701 2500701 2500701 250201 25? ...

  • Heatcraft Refrigeration Products H-IM-77D - page 6

    6 T ypical System Wiring Diagram with Thin Profile Electric Defrost Unit Cooler ...

  • Heatcraft Refrigeration Products H-IM-77D - page 7

    7 FOR FOOD SERVICE INST ALL A TIONS . . . seal any joint between unit cooler and cooler liner with a sealant listed by the National Sanitation Foundation, Standard 51 NOMENCL A TURE L T A 053 A A Vintage A = Air Defrost A = 115-1-60 L = Electric Defrost B = 208/20-1-60 S i z e Extended Thin Profile Unit Cooler Dimensional Diagram Extended Thin P ...

  • Heatcraft Refrigeration Products H-IM-77D - page 8

    8 Extended Thin Profile Unit Cooler (continued) Motor / F an Blade / Fan Guard Defrost Heater Cabinet Components Electrical Components Drain Fitting Mounting This unit cooler is designed for mounting from the top of the cooler . Dr ill holes for screws in accordanc e with mounting dimensions given in Dimensional Diagram and Data. After unpack ing t ...

  • Heatcraft Refrigeration Products H-IM-77D - page 9

    9 V Profile Unit Cooler Dimensional Diagram Mounting The V prole un it cooler is d esigne d for mo untin g from the top or t he back wall of the coo ler . Dril l hole s for screw s in acco rdance w ith mo unt- ing dimensions given in Dimensional Data. Afte r unpa ck ing t he uni t, se cure top of un it to ce ilin g or b ack wa ll an d ar rang e ...

  • Heatcraft Refrigeration Products H-IM-77D - page 10

    10 Dimensional Data Connections (In.) Approx. Model Dimensions (In.) Coil Ship Wt. No. A B C D W Inlet Suction Drain (Lbs.) 1 12 5 / 8 12  / 8 11 7 / 16 1  / 8 14 1 / 4  / 8 OD  / 8 ID 1 / 2 OD 16 17 15 5 / 8 12  / 8 14 7 / 16 1  / 8 17 1 / 4  / 8 OD 1 / 2 ID 1 / 2 OD 17 2 21 5 / 8 12  / 8 21 1 / 16 7 / 8 22  / 4 ? ...

  • Heatcraft Refrigeration Products H-IM-77D - page 11

    11 Standard or Connections (In.) Approx. Reverse Flow Dimensions (In.) Coil Shipping Models H L M W Inlet Suction Drain Wt. (Lbs.) 1 17  / 4 16 7 / 8 12 1 / 4 15 5 / 8  / 8 OD  / 8 OD 5 / 8 OD 19 17 19  / 4 16 7 / 8 14 1 / 4 15 5 / 8  / 8 OD  / 8 OD 5 / 8 OD 20 2 19  / 4 2 1 / 4 14 1 / 4 22  / 8 OD 1 / 2 OD 5 / 8 OD ...

  • Heatcraft Refrigeration Products H-IM-77D - page 12

    12 W all Mount Back Bar Unit Cooler Dimensional Diagram Mounting The Wall Mount Back Bar Unit Cooler is a lo w height unit designed for undercounter applications . Air is drawn in at the bottom of the unit and discharged out the front. T wo mounting angles are included with the unit and should be installed to space the unit 3/4” o the wall. Ai ...

  • Heatcraft Refrigeration Products H-IM-77D - page 13

    1 Air Defrost Wiring, Model BBM Electric Defrost Wiring, Model BBL ...

  • Heatcraft Refrigeration Products H-IM-77D - page 14

    14 Dual Aire Unit Cooler Recognized Component Underwriter’s Lab., Inc. FOR FOOD SERVICE INST ALL A TIONS . . . seal any joint between unit cooler and cooler liner with a sealant listed by the National Sanitation Foundation, Standard 51 Mounting 1. Dri ll h oles in ceiling or back wall and inser t #10 screws to within 1/16” of sur face. 2. Attac ...

  • Heatcraft Refrigeration Products H-IM-77D - page 15

    15 T win Approx. Flow Dimensions (In.) F an Ship Wt. Model A B C D E F G H J K L M Qty . Dia. (Lbs.) 09 16 1 / 8 19 1 / 8 7 9 / 16 4 2 5 / 16 9 9 / 16 2  / 4 4 7 / 8 4 1 / 2 8 5 / 8 2 1 / 2 2 5 / 8 1 5 1 / 2 ” 12 1 16 1 / 8 19 1 / 8 7 9 / 16 4 2 5 / 16 9 9 / 16 2  / 4 4 7 / 8 4 1 / 2 8 5 / 8 2 1 / 2 2 5 / 8 2 5 1 / 2 ” 14 18 16 1 / 8 1 ...

  • Heatcraft Refrigeration Products H-IM-77D - page 16

    Since product improv ement is a continuing eort, we reserve the right to make changes in specications without notice . InterLink is your one-source supplier for a complete line of dependable and c ertied commercial refrigera tion parts, accessories and electronic controls. E ver y product is built to ensure the same high performance standa ...

メーカー Heatcraft Refrigeration Products カテゴリー Fan

Heatcraft Refrigeration Products H-IM-77Dのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- H-IM-77Dの取扱説明書
- Heatcraft Refrigeration Productsの製品カード
- パンフレット
- またはHeatcraft Refrigeration Products H-IM-77Dの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heatcraft Refrigeration Products H-IM-77Dの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heatcraft Refrigeration Products H-IM-77Dの取り付け説明書、サービスマニュアル、簡易説明書、またはHeatcraft Refrigeration Products H-IM-77Dのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heatcraft Refrigeration Products H-IM-77Dの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Heatcraft Refrigeration Products H-IM-77Dデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeatcraft Refrigeration Products H-IM-77Dを使用するのを助ける技術的文書のことです。説明書は通常、全てのHeatcraft Refrigeration Products H-IM-77Dユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heatcraft Refrigeration Productsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heatcraft Refrigeration Products H-IM-77Dの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeatcraft Refrigeration Products H-IM-77Dの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heatcraft Refrigeration Products H-IM-77Dに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heatcraft Refrigeration Products H-IM-77Dデバイスの基本機能を使うにあたってのヒント。 Heatcraft Refrigeration Products H-IM-77Dのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heatcraft Refrigeration Products H-IM-77Dに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeatcraft Refrigeration Products H-IM-77Dのメーカー/サービスへの連絡先に関する情報。

Heatcraft Refrigeration Products H-IM-77Dについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeatcraft Refrigeration Products H-IM-77Dの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeatcraft Refrigeration Products H-IM-77Dで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)