Mitsubishi Electronics FX0N-232ADPの取扱説明書

12ページ 0.47 mb
ダウンロード

ページに移動 of 12

Summary
  • Mitsubishi Electronics FX0N-232ADP - page 1

    This manual contains text,diagrams and explanations which will guide the reader in the correct installation and operation of the FX 0N -232ADP and should be read and understood before attempting to install or use the unit. Further information can be found in the FX SERIES PROGRAMMING MANUAL and FX 0 /FX 0N HARDWARE MANUAL. USER'S GUIDE JY992D5 ...

  • Mitsubishi Electronics FX0N-232ADP - page 2

    ● The FX 0N -232ADP type RS232C adapter (hereinafter called 232ADP) is connected to the FX 0N series PC to exchange serial data with a personal computer, barcode reader, printer, and other various RS232C devices. ● Only one 232ADP unit can be connected to one base unit to the serial port provided at the left side. ● The buffer size and locati ...

  • Mitsubishi Electronics FX0N-232ADP - page 3

    Transmission standard Conforming to RS232C, 25pin D-SUB, connector used Isolation method Photo coupler isolation Transmission distance 15m or less (shielded cable recommended) Current consumption DC 5V less than 200mA from base unit Control flags and data registers M8121:Send wait flag D8120:System configuration M8122:Send flag D8122:Remainder of s ...

  • Mitsubishi Electronics FX0N-232ADP - page 4

    *1 The default value is STX (02H: changeable). *2 The default value is ETX (03H: changeable). ● The communication format is set by special data register D8120. Setting the communication format using D8120 is effective only at the time the RS instruction is driven, and therefore any change after driving is not actually accepted. ● An example of ...

  • Mitsubishi Electronics FX0N-232ADP - page 5

    WIRING When RS232C device uses pins 6,20 When RS232C device uses pins 4,5 RS232C device 232ADP RS232C device 232ADP ● The connections of RS232C devices varies with each device being used. Check the specification of the device, and connect. Connection examples ● Terminal specification device ● Modem specification device When RS232C device uses ...

  • Mitsubishi Electronics FX0N-232ADP - page 6

    PROGRAM EXAMPLES Printer • Receive data FX 0N series sequencer Send • Send data ● The communication format of the serial printer is as follows. ● Connecting 232ADP and a printer,and printing out the data sent from the PC. Common pin out for printer communication X000,ON X001,ON Power on RS instruction drive Data send Turn on the power of th ...

  • Mitsubishi Electronics FX0N-232ADP - page 7

    ● Connect 232ADP and a personal computer,and exchange data with the PC. ● Use the communication cable suited to the connector pin configuration of the personal computer. (For representative wiring see section 4.) Personal computer • Send data • Receive data FX 0N series sequencer • Receive data • Send data Receive Send Preparation of so ...

  • Mitsubishi Electronics FX0N-232ADP - page 8

    Sequence program Power on X000,ON RS instruction drive Turn on the power of the PC and printer, check the printer is on line and switch the PC to RUN. Turn on X000, and drive RS instruction. Data send X001,ON Every time X001 is turned on, the contents of D200 to D210 are sent to the personal computer, and "test data" is displayed. Data se ...

  • Mitsubishi Electronics FX0N-232ADP - page 9

    DIAGNOSTICS ● If sending and receiving using these programs is successful, it is considered that the operation failure was due to sequence program or communication protocol error. ● Program when receiving * Write the data to be sent to D 0 to D 19 before operating. ● If not operating normally when using these programs, eliminate the cause usi ...

  • Mitsubishi Electronics FX0N-232ADP - page 10

    NO NO YES NO YES Start Is power LED lit? Is M8063 turned on? • Check connection with the PC. • Check power source of PC. • There is a possibility of send crosstalk. Check the send and receive timing with the external RS232C device. • The receive data length may exceed the receive data area. Check the receive data length and timing of receiv ...

  • Mitsubishi Electronics FX0N-232ADP - page 11

    YES NO YES NO YES Is RD LED (receive) lit? Is M8123 turned on? No receive completion All data is received? • Check wiring of RS232C cable. • Make sure wiring of control line is suited to the external device. • Make sure the external sending device is normal. • Check the voltage level of RS232C signal. NO (Monitoring D8123) • Check if rece ...

  • Mitsubishi Electronics FX0N-232ADP - page 12

    Guidelines for the safety of the user and protection of the FX 0N -232ADP • This manual has been written to be used by trained and competent personnel. This is defined by the European directives for machinery, low voltage and EMC. • If in doubt at any stage during the installation of the FX 0N -232ADP always consult a professional electrical en ...

メーカー Mitsubishi Electronics カテゴリー Network Card

Mitsubishi Electronics FX0N-232ADPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FX0N-232ADPの取扱説明書
- Mitsubishi Electronicsの製品カード
- パンフレット
- またはMitsubishi Electronics FX0N-232ADPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mitsubishi Electronics FX0N-232ADPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mitsubishi Electronics FX0N-232ADPの取り付け説明書、サービスマニュアル、簡易説明書、またはMitsubishi Electronics FX0N-232ADPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mitsubishi Electronics FX0N-232ADPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Mitsubishi Electronics FX0N-232ADPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMitsubishi Electronics FX0N-232ADPを使用するのを助ける技術的文書のことです。説明書は通常、全てのMitsubishi Electronics FX0N-232ADPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mitsubishi Electronicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mitsubishi Electronics FX0N-232ADPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMitsubishi Electronics FX0N-232ADPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mitsubishi Electronics FX0N-232ADPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mitsubishi Electronics FX0N-232ADPデバイスの基本機能を使うにあたってのヒント。 Mitsubishi Electronics FX0N-232ADPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mitsubishi Electronics FX0N-232ADPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMitsubishi Electronics FX0N-232ADPのメーカー/サービスへの連絡先に関する情報。

Mitsubishi Electronics FX0N-232ADPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMitsubishi Electronics FX0N-232ADPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMitsubishi Electronics FX0N-232ADPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)