Desa DVF34の取扱説明書

36ページ 1.18 mb
ダウンロード

ページに移動 of 36

Summary
  • Desa DVF34 - page 1

    DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL NA TURAL GAS MODEL DVF34 PROP ANE/LP GAS MODEL DVF34P Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call y ...

  • Desa DVF34 - page 2

    2 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any st ...

  • Desa DVF34 - page 3

    3 106424 OWNER’S MANUAL PRODUCT IDENTIFICA TION Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code, ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] Installation Codes (Canada) . *Available from: American National Standards Institute, In ...

  • Desa DVF34 - page 4

    4 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P Fireplace size D x FW x RW 34" 18 1 / 2 " 34 3 / 8 " 14" PRE-INST ALLA TION PREP ARA TION LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your FMI direct-vent fireplace. Make sure that rafters and wall studs are not in ...

  • Desa DVF34 - page 5

    5 106424 OWNER’S MANUAL 29" 13" 12 5 / 8 " 34 3 / 8 " 35 1 / 16 " 58" 9 1 / 4 " 41" Nailing T abs PRE-INST ALLA TION PREP ARA TION Continued Figure 6 - Framing Clearances for Corner Installation LOCATION OF VENT TERMINATION When locating vent termination, it is impor- tant to observe the minimum clearances ...

  • Desa DVF34 - page 6

    6 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P Figure 8 - Minimum Clearances for Vent Terminations GENERAL VENTING Continued Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHI ...

  • Desa DVF34 - page 7

    7 106424 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Fail- ure to do so could result in serious injury, property damage or loss of life. Operation of improperly in- stalled and maintained venting sys- tem could result in serious injury, property damage or loss of life. WARNING: Seal al ...

  • Desa DVF34 - page 8

    8 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed. Snorkel ter ...

  • Desa DVF34 - page 9

    9 106424 OWNER’S MANUAL VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 12 - Vent Opening Requirements Continued 3. Attach vent pipe assembly to the fireplace. Set fireplace in front of it’ s per- manent location ...

  • Desa DVF34 - page 10

    10 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P VENTING INST ALLA TION Continued UP UP Horizontal V enting V ertical (V) Horizontal (H) 37" min. 10" max. Figure 16 - Horizontal Termination Configuration for Rigid Venting Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90 ° Elbow Horiz ...

  • Desa DVF34 - page 11

    11 106424 OWNER’S MANUAL VENTING INST ALLA TION Continued UP V enting with T wo 90 ° Elbo ws V ertical (V) Horizontal (H 1 ) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' min. 20' max. 20' max. 8' max ...

  • Desa DVF34 - page 12

    12 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 20). Whenever possible, use 45 ° elbows instead of 90 ° elbows. The 45 ? ...

  • Desa DVF34 - page 13

    13 106424 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 22 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 23 - Installed Cathedral Ceiling Support Box Vertical Termination Configurations Figures 24 through 27 show four different configurations for vertical ...

  • Desa DVF34 - page 14

    14 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P V er tical V enting V = 40' max. Figure 27 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 9 0 ° Elbo ws V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' min. 18 ...

  • Desa DVF34 - page 15

    15 106424 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your FMI direct-vent fireplace has been AGA tested and approved for elevations from 0-2000 feet and CGA certified for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rati ...

  • Desa DVF34 - page 16

    16 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P INSTALLING OPTIONAL BLOWER ACCESSORY IMPORTANT : For clarity, gas valve assem- bly and grate/burner assembly are not shown in Figures 29 through 32 , page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown wit ...

  • Desa DVF34 - page 17

    17 106424 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued WARNING: Never touch the blower wheel while in operation. 10 . Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control bracket (Figure 32). WARNING: Failure to position the parts in accord ...

  • Desa DVF34 - page 18

    18 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P Figure 34 - Gas Connection * The CSA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check yo ...

  • Desa DVF34 - page 19

    19 106424 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator . 2. Cap of f open end ...

  • Desa DVF34 - page 20

    20 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P FIREPLACE INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 36). 2. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas v ...

  • Desa DVF34 - page 21

    21 106424 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued Figure 39 - Attaching Alkaline Battery to Receiver 9-Volt Alkaline Battery Receiver Terminal Wires Battery Clip 1. Open bottom louver and locate the switch bracket on the left. 2 . Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receive ...

  • Desa DVF34 - page 22

    22 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P INSTALLING OPTIONAL BRICK LINER D8037A WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before installing brick liner. This brick liner kit is optional. You may purchase brick liner from your local retailer or see Accessories , page 34. CAUTION ...

  • Desa DVF34 - page 23

    23 106424 OWNER’S MANUAL WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken. FIREPLACE INST ALLA TION Continued NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner could cause performance problems. Each log is marked with a number ...

  • Desa DVF34 - page 24

    24 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P MANUAL LIGHTING PROCEDURE OPERA TING FIREPLACE WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the ...

  • Desa DVF34 - page 25

    25 106424 OWNER’S MANUAL O F F P I L O T O N L O I H ON OFF REMOTE ON OFF OPERA TING FIREPLACE Continued OPERATING OPTIONAL BLOWER ACCESSORY Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel. Both the GA3700 man ...

  • Desa DVF34 - page 26

    26 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P PILOT AND BURNERS • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint. • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, ...

  • Desa DVF34 - page 27

    27 106424 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit. POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor cable pi ...

  • Desa DVF34 - page 28

    28 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ticking noise just ...

  • Desa DVF34 - page 29

    29 106424 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re ...

  • Desa DVF34 - page 30

    30 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P SER VICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP gas supply might be low (propane/LP units only) When Gas Quality Is Bad • pilot will not stay lit • b ...

  • Desa DVF34 - page 31

    31 106424 OWNER’S MANUAL SPECIFICA TIONS DVF34 DVF34P Btu 15,000/21,000 Btu/h 16,000/20,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. Dimension, Inches/mm (HxWxD) Fireplace (Actual size of firebox. Measurements do not 32 3 / ...

  • Desa DVF34 - page 32

    32 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P 47 1 2 3 4 6 6 35 5 5 5 1 1 (Included in Hardware Pack) 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 31-1 31-4 31-2 31-3 33 32 32 34 46 36 37 39 38 42 40 41 6 44 43 45 ILLUSTRA TED PA R T S BREAKDOWN DVF34 DVF34P ...

  • Desa DVF34 - page 33

    33 106424 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE DVF34 DVF34P This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 104445-01 Top Outer Casing-34" 1 2 105278-01 Outer Casing-34" 1 ...

  • Desa DVF34 - page 34

    34 106424 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE/ L P ) DVF34, DVF34P MANUAL BLOWER KIT GA3700 Manual-variable control blower accessory for the DV F Series fireplaces. THERMOSTATICALLY- CONTROLLED BLOWER KIT DA3610TA Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- ...

  • Desa DVF34 - page 35

    35 106424 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Desa DVF34 - page 36

    LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the ...

メーカー Desa カテゴリー Outdoor Fireplace

Desa DVF34のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DVF34の取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa DVF34の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa DVF34の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa DVF34の取り付け説明書、サービスマニュアル、簡易説明書、またはDesa DVF34のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa DVF34の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa DVF34デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa DVF34を使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa DVF34ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa DVF34の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa DVF34の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa DVF34に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa DVF34デバイスの基本機能を使うにあたってのヒント。 Desa DVF34のユーザーが使い始めるのを助けてくれるはずです。